1. Catalogs
  2. Sentry Equipment
  3. Twist Lock Cell Holdedr (TLC)

Twist Lock Cell Holdedr (TLC)

Twist Lock Cell Holdedr (TLC)

Twist Lock Cell Holdedr (TLC)

Product catalog summary
Overview: The Sentry TLC twist-lock cell holder is designed for easy removal and maintenance of conductivity probe sensors, which measure total dissolved solids in water samples. This system eliminates the need for tools and reduces maintenance time.
Model: TLC
Benefits: Traditional stainless steel cell holders require labor-intensive maintenance and can lead to twisted cords and thread galling. The Sentry TLC twist-lock cell holder addresses these issues by allowing quick release of the probe holder, preventing twisted cables, and enabling easy replacement with a simple quarter turn.
Features:
  • Stop pins for quarter-turn insertion and removal without visual alignment.
  • 1/4-inch NPT end fittings compatible with any system.
  • Time-saving during calibration and maintenance.
  • Adapter remains in place during cleaning and calibration, preventing cord twisting.
  • Probe removal and reinstallation takes approximately five seconds.
Specifications:
  • Pressure rating: 100 psig at 100°F (7 barg at 38°C), 60 psig at 180°F (4 barg at 82°C).
  • Temperature rating: Maximum 180°F (82°C).
  • Flow: Maximum 1500 cc per minute.
  • Recommended pH range: 6–10 pH.
  • Wetted materials: Copolymer Acetal, Viton.
  • Shipping weight: 7.5 oz (213 g).
Part Numbers:
  • TLC-075 Twist-Lock Holder with 3/4 inch NPT cell adapter 6-05273A.
  • TLC-050 Twist-Lock Holder with 1/2 inch NPT cell adapter 6-05273B.
  • Adapter, 3/4 inch NPT 2-00953P.
  • Adapter, 1/2 inch NPT 2-00953Q.
  • Holder 2-00953N.
  • O-ring 4-05907A.
Usage: The Sentry TLC can replace threaded stainless steel versions, reducing labor and preventing thread galling. It is suitable for various sample conditioning applications, including gas, liquid, slurry, solid, powder, steam, and water.
See more

Catalog excerpts

Twist Lock Cell Holdedr (TLC)-1

Solid & Powder Steam & Water SAMPLE CONDITIONING The Sentry® TLC twist-lock cell holder allows users to easily remove conductivity probe sensors - used to find the concentration of total dissolved solids in a water sample - for maintenance without tools. The twist-lock cell holder saves significant time during calibration and maintenance and allows users to easily and quickly swap sensors between cell holders while troubleshooting. MODEL TLC BENEFITS With industry-standard stainless steel cell holders for the probes, the maintenance process can be labor intensive, and because the probes are threaded into the cell holders, cords often are twisted, increasing the possibility of breaking the wires. Plus, thread galling or seizing, which is common with stainless steel due to the wearing between metal surfaces also occurs relatively frequently, requiring replacement of either or both the probe and the holder. Solving these issues, the Sentry TLC twist-lock cell holder provides quick release of the probe holder and prevents twisted cables. The adapter threads onto the probe, which allows the operator to remove the conductivity cell from the Sentry TLC and replace it easily with a quarter turn of the wrist. Easy assembly involves applying Teflon tape to the sensor threads, and then threading the adapter onto the sensor with the O-ring pointed toward the sensor tip. Then the user simply hand tightens it firmly to ensure that the adapter will not become loose when it is inserted and removed from the holder. Stop pins allow this insertion and removal without the operator needing to see the process or visually align the threads. Removing and reinstalling a probe with the Sentry TLC takes only about five seconds. The Sentry TLC can be used in place of a threaded stainless steel version, requiring much less labor, preventing thread galling and needed replacement of the probe and/or holder. Adapter never has to be removed, as it does not interfere with cleaning or calibration, and there is no cord twisting Removing and reinstalling a probe with a TLC holder takes only about five seconds FEATURES ■ Stop pins provide for quarter-turn insertion and removal without visual alignment ■ End fittings are 1/4-inch NPT to fit any system ■ Saves time during calibration and maintenance Sample. Monitor. Measure.

 Open the catalog to page 1
Twist Lock Cell Holdedr (TLC)-2

SENTRY TLC TWIST-LOCK CELL HOLDER > SAMPLE CONDITIONING ACCESSORIES > SAMPLE CONDITIONING PART NUMBERS COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV GL = ISO 9001 = sentry-equip.com 966 Blue Ribbon Circle North, Oconomowoc, WI 53066 U.S.A. | +1-262-567-7256 | [email protected] © 2015 Sentry Equipment Corp. All rights reserved. All product and company names are property of their respective owners. It is solely the responsibility of end users, through their own testing and analysis, to select products and materials suitable for their specific application requirements, ensure they are properly...

 Open the catalog to page 2

All Sentry Equipment catalogs and technical brochures

  1. DCCP Reboiler

    2  Pages

  2. AutoVREL

    2  Pages

  3. VREL

    2  Pages

  4. Blowdown XC

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.