1. Catalogs
  2. Sentry Equipment
  3. Thermal Shut Off Valve (TSV)

Thermal Shut Off Valve (TSV)

Thermal Shut Off Valve (TSV)

Thermal Shut Off Valve (TSV)

Product catalog summary
Overview: The Sentry TSV is a mechanical device designed to protect operators, analyzers, and sampling components from high-temperature liquids. It serves as a mechanical alternative to solenoid shutoff valves and temperature controllers, operating without electricity, air, or hydraulics. The device activates in less than five seconds when exposed to high temperatures.
Model: TSV
Benefits: The Sentry TSV offers reliable mechanical operation with positive closure, requiring manual reset after activation to ensure system issues are resolved before resuming flow. It is installed downstream of pressure-reducing devices and upstream of analyzers and flowmeters. A red indicator shows valve position, and an optional switch can signal a remote alarm.
Features:
  • Protects operators and equipment
  • Handles system pressures up to 4400 psi (303 bar)
  • Flow shutdown in less than five seconds
  • Mechanical design without electricity, air, or hydraulics
  • Push-button reset
  • Optional remote alarm indication
  • Visual trip indication
  • Standard trip temperature of 120°F (49°C), with other options available
Wetted Materials: 316 stainless steel and elastomers compatible with boiler water and steam. Kalrez elastomers are available for hydrocarbon applications.
Specifications:
  • Pressure rating: 4400 psi (303 bar)
  • Downstream pressure rating: 250 psi (17 bar)
  • Temperature rating: 250°F (121°C)
  • Trip temperature: 120°F (49°C)
  • Pressure drop: Cv=0.21
  • Wetted materials: 316 SS, Viton®, PEEK
  • Connections: 1/4 in tube stubs
  • Shutoff time: Less than 5 seconds
  • Reset time: Temperature must drop 2–3°F (1–2°C) below set point
  • Shipping weight: 1.75 lb (794 g)
  • Optional elastomer: Kalrez®
  • Optional position indicating dry contact specifications: SPDT (form C) - NOHC, NEMA 1, 2, 3, 4 & IEC IP-67
  • Contact ratings: 10 A at 125 and 250 VAC; 0.5 A at 125 VDC; 0.25 A at 250 VDC; NEMA A300
Manufacturing: The product is manufactured under U.S. patent 5,826,790.
Disclaimer: Users are responsible for selecting suitable products and materials for their applications, ensuring proper installation, safe application, and maintenance. Improper use may result in injury or damage.
See more

Catalog excerpts

Thermal Shut Off Valve (TSV)-1

- SENTRY TSV THERMAL SHUTOFF VALVE O Liquid & siurry Thermal Protection Valves Solid & Powder Steam & Water SAMPLE CONDITIONING The Sentry® TSV is a self-contained, mechanical device that protects operators, analyzers and sampling components from high temperature liquids. It is an economical and reliable mechanical replacement for a solenoid shutoff valve and temperature controller, requiring no external source of electricity, air or hydraulics. The sensor/actuator is directly exposed to the sample medium. High temperatures actuate the device in less than five seconds. Some of the causes of high temperatures include loss of cooling water, insufficient cooling water pressure or flow, high cooling water temperature, high sample flow rate, a ruptured coil in the sampler cooler, or a fouled or plugged sample cooler. MODEL TSV BENEFITS A reliable mechanical solution that requires no electricity to operate, the Sentry TSV provides positive closure. It must be manually reset after a trip, which ensures that sample flow is not resumed before the cause of the system upset has been corrected. The Sentry TSV should be installed downstream of the pressure-reducing device and upstream of analyzers, flowmeters and other low-pressure devices. After a trip, the upstream side of the Sentry TSV will be exposed to the full source pressure. A red indicator readily provides visual indication of valve position, and an optional switch is available to provide a signal for a remote alarm. FEATURES ■ Protects operators and equipment ■ Suitable for system pressures up to 4400 psi (303 bar) ■ Flow shutdown in less than five seconds ■ Completely mechanical design requires no electricity, air or hydraulics ■ Push-button reset ■ Optional dry contact for remote alarm indication ■ Visual trip indication ■ Standard trip temperature is 120°F (49°C) with other temperatures available Wetted materials ■ 316 stainless steel and elastomers compatible with boiler water and steam Consult us for use with other media ■ Option: Kalrez elastomers suitable for hydrocarbon applications (limited setpoints available) Manufactured under one or more U. S. patents: 5,826,790 Sample. Monitor. Measure.

 Open the catalog to page 1
Thermal Shut Off Valve (TSV)-2

SENTRY TSV THERMAL SHUTOFF VALVE > THERMAL PROTECTION VALVES > SAMPLE CONDITIONING SPECIFICATIONS Viton and Kalrez are registered trademarks of E. I. Du Pont de Nemours and Company. COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV GL = ISO 9001 = sentry-equip.com 966 Blue Ribbon Circle North, Oconomowoc, WI 53066 U.S.A. | +1-262-567-7256 | [email protected] © 2017 Sentry Equipment Corp. All rights reserved. All product and company names are property of their respective owners. It is solely the responsibility of end users, through their own testing and analysis, to select products and materials...