SENTRY SINGLE LINE Single Line Conditioning Module Solid & Powder Steam & Water Sentry® single line sample panels are pre-piped assemblies used to simplify the conditioning of steam, water or non-hazardous process samples. With the addition of cooling water, safe and representative samples can be obtained from individual sampling sites that are remotely located throughout the plant or from a small number of samples in a central location. There are two versions of Sentry single line sample panels — one for grab samples only (SL100) and the other for both grab samples and to condition the sample for on-line analysis (SL200). MODELS SL100L | SL100H | SL200L | SL200H BENEFITS Sentry single line panels can be mounted in a variety of rack configurations to create custom sample systems. Both the freestanding and wall mountable racks come with full-width worktable sinks and pre-piped cooling water headers to reduce installation time and cost. Whether an individual single line sample panel or an integrated rack, solutions are completely engineered to meet the application requirements. FEATURES Low pressure models (SL100L & SL200L) are appropriate for samples up to 500 psig at 450°F (34 barg at 232°C) High pressure models (SL100H & SL200H) handle samples up to 3030 psig at 1000°F (209 barg at 538°C) High pressure panels rated up to 5000 psig (345 barg) are available upon request Individual single line panels or multipanel racks can be customized to meet your specific requirements Complete mechanical and electrical systems with full documentation are available Add an analyzer or other analysis product Create a complete sample system with analyzers and conditioning on the same rack Use the back side of a freestanding floor rack to mount analysis equipment Combine critical conditioning and analysis on a portable skid
Open the catalog to page 1Components TLR-4225 Sample Cooler (SC-1) Temperature Indicator (TI-1) Sink Cooling Water Valves Sample Isolation Valve (V-1/V-2) Pressure Reducing Valve (PCV-1 or VREL) Back Pressure Regulator (BPR/RV) sample inlet sample inlet Opt cooling water outlet Total Flow Indicator (FI) TI 1 FLR-6225 Sample Cooler (SC-1) Cooling Water Sight Glass (CWSG) Secondary Sample Cooler (SC-2) inlet blowdown V-4 cooling drain water inlet cooling water outlet cooling water inlet Floor/Wall Mounted Rack High Pressure Blowdown Valve Low Pressure Blowdown Valve (V-3) Sample Side Relief Valve Sample Filter (F-1) Pressure...
Open the catalog to page 22 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages
8 Pages
2 Pages
1 Page