Catalog excerpts
SENTRY MT-1 MAGNETIC TRAP Sample Conditioning Components Solid & Powder Steam & Water Magnetite particles can cause huge problems within a sampling system by jamming and plugging components. The Sentry® MT-1 magnetic trap isolates magnetite particulates to protect sample conditioning and analytical instruments from critical downtime and costly repairs. The magnetic trap uses high strength neodymium magnets in its core to attract and capture the magnetite before it can cause damage, protecting Sentry VREL® control valves, flowmeters and analyzers. To meet varying power plant needs, the magnetic trap is available in low- to highpressure models, as stand-alone traps as well as complete valve assemblies. MODELS MT-1 low-pressure model (with mounting bracket) MT-1V low-pressure model (with valve assembly) BENEFITS While conventional filters trap all particulates and choke off sample flow as the filtering media becomes plugged with contaminants, the Sentry MT-5 magnetic trap captures only entrained oxide particulate and lets the remaining particulates pass, protecting conditioning equipment while maintaining sample integrity. FEATURES Designed specifically for the extreme conditions of power plants NEVER plugs Single-stroke actuator and purge-inplace requires no tools or disassembly and prevents the introduction of O2 into the sample stream Spring-return air bleed bleeds any trapped air at start-up Available as a stand-alone trap or as a complete assembly with all necessary components Large 8.8 in² (57 cm²) magnetic surface area captures over 60 g of magnetic particulate when operated within EPRI guidelines Hydrotested for simple field retrofit or new panel installation
Open the catalog to page 1SENTRY MT-1 MAGNETIC TRAP > SAMPLE CONDITIONING COMPONENTS > STEAM & WATER SAMPLING 966 Blue Ribbon Circle North, Oconomowoc, Wl 53066 U.S.A. | +1-262-567-7256 | sales@sentry-equip.com © 2015 Sentry Equipment Corp. All rights reserved. All product and company names are property of their respective owners. It is solely the responsibility of end users, through their own testing and analysis, to select products and mate rials suitable for their specific application requirements, ensure they a re properly installed, safely applied and properly maintained, and to limit their use to their...
Open the catalog to page 2All Sentry Equipment catalogs and technical brochures
-
SENTRY ISOLOK SAA SAMPLER
2 Pages
-
SENTRY SA SAMPLER
2 Pages
-
SENTRY B1 SAMPLER
2 Pages
-
SENTRY SINGLE LINE
2 Pages
-
SENTRY VREL CONTROL VALVE
2 Pages
-
SENTRY SBC CONTROLLER
2 Pages
-
SENTRY ISOLOK MSA SAMPLE
2 Pages
-
Sample Coolers
8 Pages
-
Sample Sequencer 5
2 Pages
-
DCCP Reboiler
2 Pages
-
Corrosion Product Sampler
2 Pages
-
Resin Column (RC 100)
2 Pages
-
Resin Column (RC 200/400)
2 Pages
-
Thermal Shut Off Valve (TSV)
2 Pages
-
AutoVREL
2 Pages
-
VREL
2 Pages
-
TCU Air Cooled
2 Pages
-
Manifold Valve
2 Pages
-
Sentry Sample Coolers
8 Pages
-
Sentry Automatic Samplers
8 Pages
-
API Sampling Suite
4 Pages
-
Sample Chiller
2 Pages
-
Sample Cooler TLR
2 Pages
-
Blowdown XC
2 Pages
-
Dual Tube Coil Sanitary
2 Pages
-
Dual Tube Coil (DTC-8)
2 Pages
-
Dual Tube Coil (DTC-4)
2 Pages
-
Dual Tube Coil (DTC-6)
2 Pages
-
Spiral Heat Exchanger
2 Pages
-
SampleCooler USC
2 Pages
-
Sample Cooler WSW
2 Pages
-
Sample Cooler TRB
2 Pages
-
Sample Cooler FXR
2 Pages
-
Sample Cooler FLR
2 Pages
-
Model MSE ISOLOK®
2 Pages
-
Model MSD ISOLOK®
2 Pages
-
Sentry MT-2 Magnetic Trap
2 Pages
-
Sentry MT-5 Magnetic Trap
2 Pages
-
Sentry AutoVREL Spec Sheet
2 Pages
Archived catalogs
-
Manifold Valve
2 Pages
-
TCU Water-Cooled
2 Pages
-
TCU Air-Cooled
2 Pages
-
VREL®
2 Pages
-
AutoVREL
2 Pages
-
Twist-Lock Cell Holder (TLC)
2 Pages
-
Thermal Shut-off Valve (TSV)
2 Pages
-
Resin Column RC200/RC400
2 Pages
-
Resin Column RC100
2 Pages
-
Corrosion Products Sampler
2 Pages
-
Sample Sequencer® 5
2 Pages
-
Sample Coolers
8 Pages
-
Power Generation Solutions
6 Pages
-
Spiral Tube / Tube-in-Tube
8 Pages
-
Model RPG Data Sheet 18.1.4
2 Pages
-
Model MCL Sampler IOM
1 Pages