AutoVREL
2Pages

{{requestButtons}}

Catalog excerpts

AutoVREL - 1

Steam & Water Sampling Solid & Powder Sample Automation Steam & Water Sentry AutoVREL Flow Controller description The Sentry® AutoVREL Flow Controller allows users to automate new or existing sample panels through a well-appointed device that controls sample panel flow based on feedback from a non-contact flow meter. With the AutoVREL “smart” function, the operator only needs to set the desired sample flow and the system automatically adjusts to changes in the sample pressure. benefits Power plants that frequently cycle or have sliding pressures require lab technicians to manually adjust the variable pressure-reducing element (VREL) in their sample panels to maintain EPRI-recommended sample velocity. With reduced or reallocated staff resources, interest has increased in automating these redundant tasks. The Sentry AutoVREL Flow Controller has been developed as an alternative to the full-featured Sentry Sample Sentry II to offer an additional sample panel automation option. Control & Drive Unit Provides quick response time during system startup Can be field installed on existing sample panels Simple to set and maintain desired flow Displays current valve position Provides feedback to plant DCS via relay Can be set to display actual flow, set flow or sample temperature Responds to feedback from a Sentry TSV (Thermal Shutoff Valve) relay for increased operator safety Allows for manual operation through simple override Offers easy access to the Sentry VREL for maintenance and cleaning Non-Contact Flow Meter 966 Blue Ribbon Circle North, Oconomowoc, WI 53066 | +1-262-567-7256 | sales@sentry-equip.com |

Open the catalog to page 1
AutoVREL - 2

Steam & Water Sampling > Sample Automation > Sentry AutoVREL Flow Controller CABLE LENGTH: 5 FT MOUNTING DISTANCE: 4 FT specifications With basic hand tools by plant personnel; optional installation kit available Front side – panel only Maximum 175°F (75°C) wetted parts; 130°F (54°C) display and electronics flow range wetted materials input power 24V DC; separate power supply required enclosure rating Flow, temperature, Sentry TSV trip Visual indication of flow, setpoint, temperature; status indication relay for feedback to plant control room user interface Four keys: Up, Down,...

Open the catalog to page 2

All Sentry Equipment catalogs and technical brochures

  1. AutoVREL

    2 Pages

  2. VREL

    2 Pages

  3. Blowdown XC

    2 Pages

Archived catalogs

  1. VREL®

    2 Pages