1. Catalogs
  2. Sentry Equipment
  3. 2017 Manifold Valve

2017 Manifold Valve

2017 Manifold Valve

2017 Manifold Valve

Product catalog summary
Overview
The Sentry® manifold switching valve assembly is designed for sequencing multiple samples to a single analyzer. It is compatible with the Sentry Sample Sequencer® 5 and other control systems, available in four- or eight-port configurations, and is easy to install and configure.
Models
Two models are available: L1 (Four-port) and L2 (Eight-port).
Benefits
  • Ensures representative samples from every line with continuous sample flow.
  • Prevents cross-flow contamination with a block and bleed feature.
  • Minimizes purge time and eliminates dead legs.
  • Available in 1/8-inch and 1/4-inch valve sizes.
Features
  • No cross-flow contamination due to valve block and bleed feature.
  • Continuous sample flow in all lines.
  • All wetted surfaces are continuously swept with high-velocity samples.
  • Minimal purge time and no dead legs.
Specifications
  • Voltage: 12 VDC standard; optional 120, 240 VAC, 60 Hz (110, 220 VAC, 50 Hz) and 24 VDC.
  • Power: 7 W DC, 6.2 W AC for 1/8-inch manifold; 9.5 W DC, 8.7 W AC for 1/4-inch manifold.
  • Pressure Rating: 60 psig (4 barg) for 1/8-inch manifold; 100 psig (6.9 barg) for 1/4-inch manifold.
  • Sample Temperature Max: 130°F (54°C) for 1/8-inch manifold; 0 to 150°F (-18° to 65°C) for 1/4-inch manifold.
  • Ambient Temperature Max: 120°F (49°C) for 1/8-inch manifold; 0° to 104°F (-18° to 40°C) for 1/4-inch manifold.
  • Wetted Materials: 300 series stainless steel; Viton elastomers.
  • Weight: 4-port: 1.7 lb (0.8 kg) for 1/8-inch manifold; 6.5 lb (3.0 kg) for 1/4-inch manifold.
  • Pressure Drop: Cv = 0.06 for 1/8-inch manifold; Cv = 0.284 for 1/4-inch manifold.
  • Standards: UL, CSA, IEC, CE, ROHS for 1/8-inch manifold; UL, CSA, CE, ROHS for 1/4-inch manifold.
Dimensions
  • L1 (4-port model): 5-7/8 in. (149 mm) max for 1/8-inch manifold; 8-7/8 in. (225 mm) max for 1/4-inch manifold.
  • L2 (8-port model): 11-5/8 in. (295 mm) max for 1/8-inch manifold; 16-7/8 in. (428 mm) max for 1/4-inch manifold.
See more

Catalog excerpts

2017 Manifold Valve-1

Gas Liquid & Slurry Solid & Powder SENTRY MANIFOLD SWITCHING VALVE Sample Conditioning Automation Steam & Water The patented Sentry® manifold switching valve assembly is designed specifically for use in sequencing multiple samples to a single analyzer. It works in conjunction with the Sentry Sample Sequencer® 5 or with other control systems. It is available as either a four- or eight-port configuration and is easy to install and configure. MODELS L1 (Four-port) | L2 (Eight-port) BENEFITS To assure a representative sample from every line, all samples flow continuously, whether in or out of sequence. Normally the common sample port is closed and the sample goes through the drain port. When a solenoid coil is energized, that particular sample goes through the common port and exits to the analyzer (see figure, right). The manifold design provides flow in both directions from the open valve. This eliminates dead legs, assures complete purging of the old sample, and minimizes purge time between samples. Additionally, sample integrity is maintained with a block and bleed feature on each valve that prevents any possibility of cross-flow contamination. FEATURES No cross-flow contamination with valve block and bleed feature Continuous sample flow in all lines All wetted surfaces continuously swept with high velocity sample Manufactured under one or more U. S. patents: 5,469,751 Minimal purge time, no dead legs

 Open the catalog to page 1
2017 Manifold Valve-2

SENTRY MANIFOLD SWITCHING VALVE > SAMPLE CONDITIONING AUTOMATION > SAMPLE CONDITIONING DIMENSIONS +The Sentry Sample Sequencer 5 is designed for use with 12 VDC coils only. COMPANY WITH QUALITY SYSTEM CERTIFIED BY DNV GL = ISO 9001 = sentry-equip.com 966 Blue Ribbon Circle North, Oconomowoc, WI 53066 U.S.A. | +1-262-567-7256 | [email protected] © 2015 Sentry Equipment Corp. All rights reserved. All product and company names are property of their respective owners. It is solely the responsibility of end users, through their own testing and analysis, to select products and materials suitable...

 Open the catalog to page 2

All Sentry Equipment catalogs and technical brochures

  1. DCCP Reboiler

    2  Pages

  2. AutoVREL

    2  Pages

  3. VREL

    2  Pages

  4. Blowdown XC

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.