1. Catalogs
  2. SENSY S.A.
  3. SAFETY-BOY: FUNCTIONAL SAFETY LOAD LIMITER ELECTRONICS
video corpo

SAFETY-BOY: FUNCTIONAL SAFETY LOAD LIMITER ELECTRONICS

SAFETY-BOY: FUNCTIONAL SAFETY LOAD LIMITER ELECTRONICS

SAFETY-BOY: FUNCTIONAL SAFETY LOAD LIMITER ELECTRONICS

Product catalog summary
Overview: The SAFETY-BOY is a functional safety certified load limiter designed for overload protection in hoisting applications, meeting PL d Category 3 requirements according to EN ISO 13849-1.
Key Features:
  • Two redundant channels with constant signal comparison.
  • PFHd of 4.29 x 10-8.
  • Display for hoisted load and input signal.
  • Integrity monitoring of load cells with continuous channel comparison and internal watchdog.
  • Analogue output: 2 x 4...20 mA.
Applications:
  • Internal survey system for load cell and electronics.
  • Calibration via push buttons and display.
  • Pre-alarm and overload set-points on each channel.
  • Protection against unauthorized programming and inverted polarity of power supply.
  • Self-resetting fuse.
Specifications:
  • Types: Load limiter with IP65 housing (AC or DC power supply) and OEM version without housing.
  • Input range: Up to 3.9 mV/V.
  • Sensor excitation: 4 VDC.
  • Display: 4-digit red LED, 7 mm high.
  • Accuracy: 0.03% Full Scale.
  • Low pass filter: Selectable 0.25 to 3 Hz.
  • Internal resolution: 24 bit.
  • Service temperature range: -10 to +50°C.
  • Storage temperature range: -20 to +60°C.
  • Power supply: 100 to 240 VAC or 10 to 30 VDC.
  • Consumption: 10 W (AC) or 6 W (DC).
  • Relay: 4 cabled by 2, "Form C" pre-cabled, contact rating 2 A @ 48 VAC / 24 VDC.
  • Dimensions: Vary by model, with IP65 rating for housed versions.
Technical Drawings: Dimensions and terminal views are provided for installation reference.
See more

Catalog excerpts

SAFETY-BOY: FUNCTIONAL SAFETY LOAD LIMITER ELECTRONICS-1

Lwww.sensy.com FUNCTIONAL SAFETY CERTIFIED LOAD LIMITER ELECTRONICS Overload protection electronics for hoisting devices with certification for performance level PL d according to EN ISO 13849-1. 7 Features o 2 redundant channels with constant comparing of both signals o PFHd 4.29 x 10E-08 o Load limiter electronics certified for functional safety up to PL d Category 3, DC: medium o Display of hoisted load and input signal o Monitoring system of the integrity of load cells with continuous comparison of both channels and internal "watchdog" for the electronics o Analogue output: 2 x 4...20 mA Application^ SENSY's SAFETY-BOY is perfectly designed for the following applications: - Overload protection of hoist for PL d cat. 3 requirement. Function(s) ■ Internal survey system of load cell and electronics ■ Calibration with push buttons and display ■ With pre-alarm and overload set-points on each channels ■ Protection avoiding programming by unauthorised users ■ Protection against inverted polarity of power supply ■ Self-resetting fuse *F.S. : Full Scale. ** : max 85% humidity non-condensing. Specifications subject to change without notice.

 Open the catalog to page 1
SAFETY-BOY: FUNCTIONAL SAFETY LOAD LIMITER ELECTRONICS-2

TECHNICAL DRAWINGS: FUNCTIONAL SAFETY CERTIFIED LOAD LIMITER ELECTRONICS SAFETY-BOY OEM Power Supply L- Output Relay (Alarm) L- Output Relay (Pre-Alarm) — Load cell (Channel N'2) — Load cell (Channel N'l) L Output 4-20 mA (Channel N‘2) Output 4-20 mA (Channel N'l) Other view Dimensions in mm

 Open the catalog to page 2

All SENSY S.A. catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.