JBOX-LCI : SMART JUNCTION BOX MONITORING LOAD CELL INTEGRALITY - 1

Smart junction box is designed for parallel connecting of 2 to 4 load cells to an electronic device and for ensuring the monitoring of their correct functioning. Features o Control of: - load cell out of pre-set balance range - load cell out of pre-set operating range - low / high excitation - open circuit to any load cell on each connection - short circuit on any load cell connection - internal load cell fault (bridge imbalance) o Ensure the positive safety of load limitation systems based on multiple load cells connected in parallel (hoisting devices) Available option(s) - ABS housing available with DIN rail mounting accessories - PCB available without ABS housing Application^ SENSY's JBOX-LCI is perfectly designed for the following applications: ■ Overload protection and slack rope detection for hoisting equipment based with multiple anchor points, ■ Industrial weighing with improved reliability. Function(s) Easy calibration by keys and 4-digit display Indication of the signal (mV) of each sensor, the average signal and error message (no. of sensors and types of error) Relay normally energised Parameters protected by a secret code *F.S. : Full Scale. ** : provided by measurement electronics / 52 mA (except the consumption of the sensors). *** : as SENSY JBOX-LCI is powered by the electronics on which it is connected, this electronics has to be able to provide an extra current supply in addition to the one required by the load cells. This means that, if necessary, a higher sensor impedance (e.g.: 700 or 1000 ohms) has to be provided. Example: In the case of use of a load cell with a CRANE-BOY (capacity of 125 mA at 10 V), the remaining current supply for the load cells is 75 mA. This will therefore be sufficient for 2 load cells of 350 ohms but not for 4 load cells of 350 ohms. Specifications subject to change without notice.

Open the catalog to page 1
JBOX-LCI : SMART JUNCTION BOX MONITORING LOAD CELL INTEGRALITY - 2

TECHNICAL DRAWINGS: SMART JUNCTION BOX MONITORING LOAD CELL INTEGRITY Other view Terminals LOAD CELLSRELAYDefault Positiveposition security Wiring: +Exc. (Brown) -Exc. (Yellow) +Sig. (Green) -Sig. (White) SCR [Screen cable)

Open the catalog to page 2

All SENSY S.A. catalogs and technical brochures

Archived catalogs