1. Catalogs
  2. SENSY S.A.
  3. DISP-BOYDP CRANE-BOYDP : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES
video corpo

DISP-BOYDP CRANE-BOYDP : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES

DISP-BOYDP CRANE-BOYDP : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES

DISP-BOYDP CRANE-BOYDP : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES

Product catalog summary
Overview: The document details the features and specifications of SENSY's DISP-BOYDP and CRANE-BOYDP, designed for overload protection and slack rope detection in various crane applications, including overhead, container, and gantry cranes.
Specifications:
  • Both models serve as load limiters for dual 4-20 mA load cells.
  • Input range: 2 x 20 mA (-26 to +26 mA).
  • Sensor excitation: 18 VDC ± 20% @ 70 mA max per input channel.
  • Display: 5 digits (14.2 mm).
  • Accuracy: 0.1% Full Scale.
  • A/D converter: 16 bits with a rate of up to 20 readings per second.
  • Service temperature range: 0 to +50°C; Storage temperature range: -40 to +60°C.
  • Power supply options: 85-250 VAC, 50/60 Hz or 18-36 VDC, 24 VAC.
  • Relay type: "Form A"- potential free with a contact rating of 3 A @ 250 VAC / 30 VDC.
  • IP rating: IP54 for front panel only.
Features:
  • Easy and intuitive calibration with display of hoisted loads and input signals.
  • Internal monitoring system for load cells and electronics (fail-safe).
  • Intelligent filter for quick reaction to overloads.
  • Math functions (+, -, *, /) can be performed on signals.
  • Analogue output options: 4(0)…20 mA or 0…10 V.
  • Communication capabilities: RS-232, RS-485, fieldbus.
  • Protection: NEMA 4X/IP65 with optional "COVER PAX".
Applications:
  • OEM overload protection and slack rope detection for various crane types.
  • Internal survey system for load cell and electronics.
  • "TEST" button for system verification.
  • Secret code to prevent unauthorized programming.
Options:
  • Analogue output cards and relay cards available.
  • Communication interfaces: Modbus, DeviceNet, Profibus-DP.
Technical Drawings: The document includes standard dimensions and technical drawings for installation and configuration purposes.
See more

Catalog excerpts

DISP-BOYDP CRANE-BOYDP : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES-1

Lwww.sensy.com CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES Electronics ensuring the individual limitation of loads lifted by 2 hoisting systems and limitation of the function of these loads (sum, difference, multiplication, ratio) * o Type: - DISP-BOYDP: to be installed on the front panel - CRANE-BOYDP: with industrial metallic housing o Easy and intuitive calibration o Display of hoisted loads and input signals o Internal monitoring system of the integrity of load cells and load limitation electronics (fail safe) Available option(s) Application^ - Analogue output 4 (0)...20 mA or 0...10 V - RS-232, RS-485 or fieldbus capabilities - NEMA 4X/IP65 (transparent protection cover + Option "COVER PAX" - rail DIN adaptor - power supply: 48 VAC (only for 85...230 VAC version) - stainless steel housing SENSY's DISP-BOYDP and CRANE-BOYDP are perfectly designed for the following applications: - OEM - overload protection and slack rope detection of: overhead cranes, container cranes, gantry cranes. Function(s) ■ Internal survey system of the load cell and electronics (fail safe) ■ "TEST" button to check the correct working of the detection system ■ Secret code prohibiting programming by unauthorised users ■ Intelligent filter with quick reaction to overload while not reacting to transitory non-significant overload ■ Maximum and minimum memories, smart filter ■ A math function (+, -, * or /) can be performed on both signals *F.S. : Full Scale. ** : IP rating for front panel only. Specifications subject to change without notice.

 Open the catalog to page 1
DISP-BOYDP CRANE-BOYDP : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES-2

TECHNICAL DRAWINGS: CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES DISP-BOYDP > STANDARD DIMENSIONS Note: recommended min. clearance (behind the panel) for mounting is 140 mm deep and 53.4 mm high. Panel cut-out 92 mm (-0+0.8) 45 mm (-0+0.5) Other view

 Open the catalog to page 2
DISP-BOYDP CRANE-BOYDP : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES-3

TECHNICAL DRAWINGS: CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES CRANE-BOYDP > STANDARD DIMENSIONS Other view

 Open the catalog to page 3
DISP-BOYDP CRANE-BOYDP : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES-4

Communication cards (max. 1 choice) CARD-CDC1C RS-485 field bus communication interface Available with crew terminals or DB9 connector CARD-CDC2C FEMALE PIN 2 TXD PIN 3 RXD PIN 5 COMMON * As the CARD-CDC50 is too long for the housing of the CRANE-BOY, the CARD-CDC50-CRANE is supplied with a spacer to be inserted between the front of the electronics and the housing. Analogue output card: CARD-CDL10 Relay card: CARD-CDS20 (4 set-points) Models: CABIN-2xB1SUMD; CABIN-4xB1SUMD Models: INDI-BOY DISP-BOYP; CRANE-BOY CRANE-BOYP; DISP-BOYDP CRANE-BOYDP; CRANE-SUMD DISP-SUMD; CRANE-BOY-Exd; CABIN-2xB1SUMD;...

 Open the catalog to page 4

All SENSY S.A. catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.