CABIN-4xB1SUMD : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 4 CHANNELS + SUM - 1

Lwww.sensy.com CRANE OVERLOAD PROTECTION ELECTRONICS FOR 4 CHANNELS + SUM JK I9k The CABIN-4IB1SUMD and CABIN-4DB1SUMD are crane overload protection systems designed to manage 4 hoisting devices as j Features x = input: - I: mV/V or - D: process input 4(0)...20 mA o Easy and intuitive calibration o Display of hoisted loads and input signals o Internal monitoring system of load cell integrity and load limitation electronics (fail safe) -Analogue output 4 (0)...20 mA or 0.10 V - RS-232, RS-485, USB or fieldbus capabilities - NEMA 4X / IP65 (transparent protection cover - option "COVER PAX") - power supply: 48 VAC (only for 85...230 VAC version) - stainless steel cabinet SENSY's CABIN-4xB1SUMD is perfectly designed for the following applications: The 4IB1SUMD and 4DB1SUMD provide housing for integrating 4 x INDI-BOY or4 x DISP-BOYP associated with 1 x DISP-SUMD. They are designed to ensure overload protection and slack rope detection of4 independent hoists as well as the sum of these loads. - Internal survey system of load cells and electronics (fail safe) - "TEST" buttons to check the correct working of the detection system - Secret code prohibiting programming by unauthorised users - Intelligent filter with quick reaction to overload while not reacting to transitory non-significant overload - Maximum and minimum memories

Open the catalog to page 1
CABIN-4xB1SUMD : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 4 CHANNELS + SUM - 2

TECHNICAL DRAWINGS: CRANE OVERLOAD PROTECTION ELECTRONICS FOR 4 CHANNELS + SUM Main power supply Contacts SUMD n°1 Contacts INDI-BOY n°4 Contacts INDI-BOY n°3 Contacts INDI-BOY n°2 Contacts INDI-BOY n°1 Load cell n°1 Load cell n°2 Load cell n°3 Load cell n°4 Dimensions in mm Other views

Open the catalog to page 2
CABIN-4xB1SUMD : CRANE OVERLOAD PROTECTION ELECTRONICS FOR 4 CHANNELS + SUM - 3

Communication cards (max. 1 choice) CARD-CDC1C RS-485 field bus communication interface Available with crew terminals or DB9 connector CARD-CDC2C FEMALE PIN 2 TXD PIN 3 RXD PIN 5 COMMON * As the CARD-CDC50 is too long for the housing of the CRANE-BOY, the CARD-CDC50-CRANE is supplied with a spacer to be inserted between the front of the electronics and the housing. Analogue output card: CARD-CDL10 Relay card: CARD-CDS20 (4 set-points) Models: CABIN-2xB1SUMD; CABIN-4xB1SUMD Models: INDI-BOY DISP-BOYP; CRANE-BOY CRANE-BOYP; DISP-BOYDP CRANE-BOYDP; CRANE-SUMD DISP-SUMD;...