TS411

TS411

TS411

Product catalog summary
Overview: The document provides technical specifications and details for the TS411 Torque Transducer by SENSOTEC Group, designed for static reaction torque measurement. It highlights the transducer's capabilities, technical data, and dimensions.
Specifications:
  • Torque measurement capacities range from 1 Nm to 5 KNm.
  • Features include high stiffness, good accuracy, and suitability for permanent installation.
  • Integrated TEDS module according to IEE141.4 standards.
  • Suitable for both mobile and standard applications with cable output.
Technical Data:
  • Combined error: < 0.2% FS
  • Relative linearity error: <0.2% FS
  • Standard error of characteristic value: <0.5% FS
  • Standard repeatability error: <0.02% FS
  • Zero signal when removed: 0.01 mV/V
  • Rated characteristic value: 1 mV/V
  • Temperature ranges: Reference (21 ºC), Rated (-10/+40ºC), Operating (-15/70ºC), Storage (-30/80ºC)
  • Temperature effects on characteristic value and zero signal per 10 K: <+/-0.002% FS
  • Input resistance: 400 +/- 25 Ohm
  • Output resistance: 350 +/-2 Ohm
  • Insulation resistance: >5 GigaOhm
  • Maximum excitation voltage: 15 Vdc
  • Rated range of excitation voltage: 5 to 10 Vdc
  • Limit Torque: <150% FS
  • Breaking torque: <300% FS
  • Max. permissible dynamic load according to DIN 50100: 70% FS
  • Degree of protection according to DIN 60529: IP 64
Design and Construction: The TS411 series features a standard square connection, stainless steel sensors, and an aluminum housing, ensuring high stiffness and accuracy. It is designed for permanent installation with an integrated TEDS module.
Nominal Ranges and Dimensions:
  • Nominal ranges include 1 Nm, 2 Nm, 5 Nm, up to 5000 Nm.
  • Dimensions vary with range, with specific measurements for A, B (square according to DIN3121), and C.
  • Comes with a 5m shielded cable, 6-core, without plug.
See more

Catalog excerpts

TS411-1

Force &Torque transducers TS411 Torque transducer *Static reaction torque measurement *Capacities from 1 Nm to 5 KNm *Suitable for permanent instrallation *High stiffness *Good accucacy *TEDS module intergrated acc. IEE141.4 *Suitable for mobile or standard application *Cable oputput The electrical torque transducers of the model series 411 with a standard square connection are excellently suitable for static reaction torque measurements. The sensors that are made of stainless steel have an aluminum housing and are characterised by their high stiffness and good accuracy. They are suitable for permanent installation. A TEDS module is already intergrated inside the device. Techical data (acc. VDI/VDE directive 2638) Combined error: < 0,,2% FS Relative linearity error: <0,2 % FS Standard error cof characteristic value : <0,5%FS Standard repeatability error : <0,02%FS Zero signal when removed : 0,01 mV/V Rated characteristic value : 1 mV/V Reference temperature : 21 ºC Rated temperature range : -10/+40ºC Operating temperature range : -15/70ºC Storage temperature range : -30/80ºC Relative creep after 30 min : <+/-0,05%FS Relative creep after 8 h : <+/-0,07%FS Temperature effect on characteristic value per 10 K : <+/-0,002%FS Temperature effect on zero signal per 10 K : <+/-0,002%FS Input resistance : 400 +/- 25 Ohm Output resistance : 350 +/-2 Ohm Insulation resistance : >5 GigaOhm Maximum excitation voltage : 15 Vdc Rated range of excitation voiltage : 5 to 10 Vdc Limit Torque : <150 % FS Breaking torque : < 300 % FS Max. Permissable dynamic load acc. to DIN 50100 : 70 %FS Degree of protection acc. To DIN 60529 : IP 64 SENSOTEC group C/Albert Einstein, 54 Nau 16 – 08940 Cornellà de Llobregat – BARCELONA - www.sensotecgr

 Open the catalog to page 1
TS411-2

Force &Torque transducers 5m shielded cable, 6-core, without plug Nominal ranges & dimmensions Range Code table Range Units (Nm) Cable length (m) Options SENSOTEC group C/Albert Einstein, 54 Nau 16 – 08940 Cornellà de Llobregat – BARCELONA - ww

 Open the catalog to page 2

All Sensotec Instruments catalogs and technical brochures

  1. LTM-8811

    2  Pages

  2. DPM-599

    4  Pages

  3. FLC-16

    4  Pages

  4. LHF-12

    2  Pages

  5. LHF-08

    2  Pages

  6. LTFC-300

    4  Pages

  7. FS-012

    2  Pages

  8. LTFM-120

    4  Pages

  9. T2N

    1  Page

  10. TRG

    2  Pages

  11. TRB-HRT

    4  Pages

  12. T-62

    2  Pages

  13. FS103

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.