T-62

T-62

T-62

Product catalog summary
Specifications:
The document describes a tension/compression load cell, Model T-62, with a nominal capacity ranging from 50 kg to 6000 kg. It is compliant with O.I.M.L. R60 class C standards, offering 3000 divisions. The measuring element is made from a steel alloy, providing durability and strength. The load cell is protected against dust and water ingress with an IP67 rating according to EN 60529 and is corrosion-resistant due to a nickel-plated treatment.
Load Capacities:
The load cell supports various capacities, including 50 kg, 100 kg, 150 kg, up to 6000 kg. It can handle a safe load of up to 300% of the nominal load (Ln) and a service load of 150% Ln.
Accuracy and Measurement:
The minimum division (vmin) is specified, ensuring precise measurements. The load cell maintains accuracy with a repeatability error of less than ±0.015% Sn and a temperature effect on zero of less than ±0.010% Sn/5°K. It operates effectively within a temperature range of -10°C to +40°C, with a broader working temperature range of -30°C to +70°C.
Electrical Specifications:
The nominal input voltage is 10 V, with an input impedance of 400 ± 20 ohms and an output impedance of 350 ± 3 ohms. The load cell includes a "SENSE" feature with two additional wires to maintain constant voltage supply, especially useful for long wires and significant temperature variations.
Applications:
The load cell is suitable for applications requiring precise tension and compression measurements, with considerations for electrical connections and signal polarity for tensile force.
See more

Catalog excerpts

T-62-1

Tension/compression load cell 3000 divisions O.I.M.L. R60 class C 3000 Teile O.I.M.L. R60 Klasse C Measuring element from Steel alloy Protected against corrosion by nickelplated treatment Korrosionsschutz durch Vernickelung Nominal capacity Accuracy class Minimum division Service load Safe load Accuracy class Kleinster Teilungswert

 Open the catalog to page 1
T-62-2

Nominal load Nennlast Transport weight Transportgewicht ELECTRICAL CONNECTION ELEKTRISCHER ANSCHLUSS: Temperature compensation Te mpe ra ture limits W ie d e rho lg e na uig k e it Te mpe ra turfe hle r: N ullpunk t Kennwert Nenntemperaturbereich Arbe its te mpe ra turbe re ic h «SENSES»: 2 additional wires to maintain a constant voltage supply at the load cell when used with proper instrumentation. Use specially when long wires and wide temperature range. body. APPLICATION» N o mina l input vo lta g e Input impe d a nc e O utput impe d a nc e N o lo a d o utput N o m. S pe is e s pa nnung Eingangswiderstand...

 Open the catalog to page 2

All Sensotec Instruments catalogs and technical brochures

  1. LTM-8811

    2  Pages

  2. DPM-599

    4  Pages

  3. FLC-16

    4  Pages

  4. LHF-12

    2  Pages

  5. LHF-08

    2  Pages

  6. LTFC-300

    4  Pages

  7. FS-012

    2  Pages

  8. LTFM-120

    4  Pages

  9. TS411

    2  Pages

  10. T2N

    1  Page

  11. TRG

    2  Pages

  12. TRB-HRT

    4  Pages

  13. FS103

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.