Product Overview: The document details the features and specifications of the Meggitt Sensing Systems' (IS) conditioner for (IS) RVDT sensor, model 690210266. This product is designed for use in explosive atmospheres and provides a 4/20mA current output proportional to the sensor core rod displacement.
Electrical Specifications: The conditioner operates with a power supply range of 15VDC to 28VDC. It supports a storage temperature range of -65°C to +150°C and an operating temperature range of -40°C to +85°C.
Mechanical and Environmental Characteristics: The conditioner is designed for hazardous areas, with dimensions of 215x121x55 mm and a weight of approximately 950 g. It is housed in an aluminum box with IP 40 protection and can withstand vibrations up to 2g. The unit features screw terminals for junctions.
Performance Specifications: The conditioner has a maximum consumption of 60mA, with a sensor supply voltage of 2.2 Veff ±20% and a sensor frequency of 3500 Hz ±10%. It includes synchronized demodulation on secondaries sum and a filter of 450 Hz ±20%. The output signal is 4/20mAdc, with load resistance ranging from 280 Ω to 730 Ω depending on the power supply voltage. The maximum non-linearity is ±0.1% FS, and the maximum accuracy error is ±0.2% FS. Zero thermal drift is ±25 ppm/°C/FS, and sensitivity thermal drift is 150 ppm/°C.
Safety and Compliance: The conditioner must be used with intrinsically safe devices, ensuring compatibility with intrinsic safety rules. It is marked with Ex ia IIC T5, Ex ia IIB T4, Ex ia IIC T4, Ex ia IIC T3, or Ex ia IIB T3, depending on the ambient temperature (Ta) and atmosphere classification.
Contact Information: For further inquiries, contact Meggitt (Sensorex) at Archamps Technopôle, 196 Rue Louis Rustin, 74166 ARCHAMPS, France. Phone: 04 50 95 43 70, Fax: 04 50 95 43 75, Websites: www.sensorex.fr, www.meggitt.com.
See more

Catalog excerpts

690210266 ATEX conditioner-1

(IS) conditioner for (IS) RVDT sensor Utilization range (IS) 690210266 signal conditioner features 6 wires inductive RVDT sensor signal treatment in explosive atmosphere. This conditioner delivers a 4 /20mA current output proportional to the sensor core rod displacement. It has two screw terminals for sensor broken wire detection or power supply failure. Meggitt (Sensorex) Archamps Technopole INDUCTEE SENSOR CONVERTER DETECTION ' IScrew terminations! Meggitt Sensing Systems Our measurement product competencies: LVDTs I Inertial systems I Inclinometers I Accelerometers I IMU I MEMS sensors I Servo-inclinometer I Conditioners extreme environments

 Open the catalog to page 1
690210266 ATEX conditioner-2

Aerospace Energy Measurement Railway (IS) conditioner for (IS) RVDT sensor 690210266 (IS) Contact Mechanical and environmental characteristics Number of channel Location unit Hazardous area Screw terminals Meggitt (Sensorex) Archamps Technopôle 196 Rue Louis Rustin www.sensorex.fr www.meggitt.com (*)Use in zone 0: the conditioner external housing includes aluminum; it shall be protected against any impact or friction. Mechanical characteristics at +25°C Power supply Maximum consumption Sensor supply voltage Sensor frequency Synchronized demodulation on secondaries sum Filter Output signal Load...

 Open the catalog to page 2

All SENSOREX MEGGITT catalogs and technical brochures

  1. SX20MExR

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.