690210266 ATEX conditioner
2Pages

{{requestButtons}}

Catalog excerpts

690210266 ATEX conditioner - 1

(IS) conditioner for (IS) RVDT sensor Utilization range (IS) 690210266 signal conditioner features 6 wires inductive RVDT sensor signal treatment in explosive atmosphere. This conditioner delivers a 4 /20mA current output proportional to the sensor core rod displacement. It has two screw terminals for sensor broken wire detection or power supply failure. Meggitt (Sensorex) Archamps Technopole INDUCTEE SENSOR CONVERTER DETECTION ' IScrew terminations! Meggitt Sensing Systems Our measurement product competencies: LVDTs I Inertial systems I Inclinometers I Accelerometers I IMU I MEMS sensors I Servo-inclinometer I Conditioners extreme environments

Open the catalog to page 1
690210266 ATEX conditioner - 2

Aerospace Energy Measurement Railway (IS) conditioner for (IS) RVDT sensor 690210266 (IS) Contact Mechanical and environmental characteristics Number of channel Location unit Hazardous area Screw terminals Meggitt (Sensorex) Archamps Technopôle 196 Rue Louis Rustin www.sensorex.fr www.meggitt.com (*)Use in zone 0: the conditioner external housing includes aluminum; it shall be protected against any impact or friction. Mechanical characteristics at +25°C Power supply Maximum consumption Sensor supply voltage Sensor frequency Synchronized demodulation on secondaries sum Filter Output signal...

Open the catalog to page 2

All SENSOREX MEGGITT catalogs and technical brochures

  1. SX20MExR

    4 Pages