1. Catalogs
  2. SENGA
  3. SENfluid - Piping system for compressed air

SENfluid - Piping system for compressed air

SENfluid - Piping system for compressed air
1 / 32 PagesView full catalog

SENfluid - Piping system for compressed air

Product catalog summary
Overview of the Compressed Air Distribution System:
The document describes a modular compressed air distribution system designed for easy assembly and environmental resistance. It is constructed from durable materials such as aluminum alloy, glass-fiber reinforced plastic, and anticorrosion treated steel.
Technical Specifications:
  • Compatible with compressed air and inert gases like argon and nitrogen.
  • Operates at pressures from 0 to 14 bar (0 to 203 Psi) and temperatures from -20°C to +80°C (-4°F to 176°F).
  • Uses extruded and calibrated aluminum pipes with specific dimensions and properties.
  • Sealing is achieved with NBR 70 Shore A quad-rings and O-rings.
  • Features BSP parallel threads and non-toxic certified electrostatic paint.
Design and Assembly:
  • No special tools are needed for assembly; pipes fit easily into fittings.
  • Ensures perfect sealing and resistance to pull out, complying with the Pressure Equipment Directive 97/23/CE art.3.3.
  • Swivel fittings allow for adaptable plant layouts.
Installation and Optimization:
  • Install with a slight slope for water drainage and use flexible hoses for thermal expansion.
  • Fixing clips should be placed every 2 meters.
  • Pipe diameters should be chosen based on pressure, installation length, and flow rate.
Tables and Data:
  • Includes tables for compressor flow rates at 7 bar and pipe diameter selection based on distance and pressure drop.
Complete Kit Specifications:
  • Includes a programmable timer, solenoid valve, and particles collector.
Spare Parts:
  • Offers programmable timers, solenoid valves, and particles collectors with various specifications.
Thread Sealing Product:
  • Anaerobic sealant for metallic threaded joints, suitable for various fluids.
Air Line Accessories:
  • Pneumatic operated blocking valves for automated fluid control, compatible with air, water, and oil.
  • Operates at a maximum pressure of 10 bar and temperatures from -20°C to +80°C.
Technical Features:
  • Nickel-plated brass body with NAMUR interface and NBR seals.
  • Pilot pressure range from 4.2 bar to 8 bar, with vacuum tightness of 740 mm Hg.
Pneumatic Operated Blocking Valves:
  • Available in normally closed and open versions with various BSP sizes.
Piloting Kit for Pneumatic Valves:
  • Includes a 3-way pneumatic switch, fittings, and polyurethane hose.
See more

Catalog excerpts

SENfluid - Piping system for compressed air-1

Système de distribution pour air comprimé Distribution system for compressed ai

 Open the catalog to page 1
SENfluid - Piping system for compressed air-2

SAS 19, route de la Salle - Z.A.C. des Romains Sud Cran-Gevrier - 74960 ANNECY FRANCE La société se réserve le droit de modifier à tout moment et sans préavis les cotes d’encombrement qui ne sont données qu’à titre indicatif. The company reserves the right to modify without prior notice the dimensions, given for reference purpose only. Conception SENGA SAS - Photos non contractuelles SENGA SAS conception - Non-cont

 Open the catalog to page 2
SENfluid - Piping system for compressed air-3

Table des matières Table of contents Le système de distribution pour air comprimé The distribution system for compressed air Informations techniques Technical datasheet Instructions de montage et démontage Optimiser son réseau d’air Optimizing your distribution system for compressed air • Choix du diamètre des tubes • Dilatation et contraction thermique Assembling accessories Junction fittings Raccords d’implantation Implantation fittings Raccords de piquage Saddle clamp connectors Raccords divers Various fittings Accessoires de ligne Air line accessories Vannes de blocage à commande pneumatique...

 Open the catalog to page 3
SENfluid - Piping system for compressed air-7

Le système de distribution pour air comprimé The distribution system for compressed air √ Montage et démontage : aucun outillage spécifique nécessaire Serrage des tubes à l’aide d’une clé Allen Assembling and disassembling : no specific tools required Attachment is made by Allen key √ Insertion des tubes dans les raccords sans effort Easy insertion of pipes in the fittings √ Réseau composé d’alliage d’aluminium, de résine plastique renforcée à 30% fibres de verre et d’acier traité anticorrosion Distribution system composed by aluminium alloy, glass-fibre reinforced plastic and anticorrosion treated...

 Open the catalog to page 7
SENfluid - Piping system for compressed air-8

Informations techniques Technical datasheet Fluides compatibles Compatible fluids • Air comprimé / Compressed air • Gaz neutres (argon, azote) Threads • BSP cylindrique : G3/4” - G1”1/4 BSP parallel : G3/4” - G1”1/4 Inert gases (argon, nitrogen) Température d’utilisation Working temperature • -20°C à +80°C (-4°F à 176°F) -20°C to +80°C (-4°F to 176°F) Tubes compatibles Suitable pipes • Tubes en aluminium extrudé et calibrés (séries 8300) Extruded and calibrated aluminium pipes (series 8300) Resistant to • Corrosion, chocs mécaniques, variations thermiques Corrosion, mechanical shocks, and thermal...

 Open the catalog to page 8
SENfluid - Piping system for compressed air-9

Le réseau d’air assure une parfaite séparation entre eau et air au niveau des descentes. √ Important : Il est fortement conseillé d’installer la canalisation principale légèrement inclinée (pente de 1%) afin de faciliter l’écoulement de l’eau vers le point de purge. En effet, une canalisation parfaitement horizontale favorise la stagnation de l’eau dans le réseau. The distribution system for compressed air separation between water and air. √ Important : It’s highly recommended to install the pipes of the main sloop with a slight slope (about 1%) in order to make water drainage easier, because...

 Open the catalog to page 9
SENfluid - Piping system for compressed air-10

Anneau d’arrêt Joint quadrilobe ou torique Bride (NBR) Quad-ring seal or O-ring (Acier INOX AISI 302) Retaining ring (Stainless steel AISI 302) (Alliage d’aluminium extrudé EN AW 6060-T6) Pipe (Extruded aluminium alloy EN AW 6060-T6) Double mors (Acier traité) Double jaw (Treated steel) Entretoise de limitation du serrage (Acier zingué) Tightening limitation spacer (Zinc plated steel) (Acier zingué) Socket head screw CHC (Zinc plated steel) (Alliage d’aluminium EN AW 6061-T6) Body (Aluminium alloy EN AW 6061-T6) Rondelle de sécurité (Acier zingué) Security washer (Zinc p

 Open the catalog to page 10
SENfluid - Piping system for compressed air-11

Instructions de montage Assembling instructions Ebavurer et nettoyer l’extrémité du tube à l’aide d’un chiffon : √ Important : L’ébavurage des tubes est impératif afin d’éviter toute détérioration des joints d’étanchéité lors du montage. De plus l’emboitement sera facilité. Les tubes ne doivent pas présenter de rayures ou de déformations au niveau des joints d’étanchéité des raccords. Burr and clean the pipe extremity with a cloth : Lime conseillée pour Ø 40 √ Important : The pipe burring is imperative in order to avoid potential degradations on the sealings during assembly. It will also help...

 Open the catalog to page 11
SENfluid - Piping system for compressed air-12

Instructions de démontage Disassembling instructions Desserrer la vis de nombreux tours : Unscrew by lots of turns : Mors débloqués Jaws unblocked Donner un coup sec sur la tête de vis puis pivoter le tube dans les deux sens dans le raccord afin de débloquer les mors : Give a sharp blow on the head screw then turn in both directions the pipe in the fitting to unblock the jaws : Sortez le tube du raccord en tirant et tournant : Remove the pipe from the fitting by pulling and turning :

 Open the catalog to page 12
SENfluid - Piping system for compressed air-13

Optimiser son réseau d’air Optimizing your distribution system Optimisations de base / Basic optimizations √ CONSTITUER le réseau principal en « boucle fermée » afin de limiter les pertes de charge. The main installation must be made in loop in order to limit pressure drops. √ CHOISIR le diamètre des tubes judicieusement selon l’utilisation souhaitée. The pipe diameter must be chosen carefully depending on the need and use. √ RACCORDER le compresseur au réseau pour éviter les vibrations. Connect the compressor to the distribution system par l’intermédiaire d’un tuyau souple, by means of a flexible...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.