Technical Data Sheet Actuators with ball valves Typical application - Actuators AVD with ball valves are used in application where only end position of the actuator is applicable. The Actuator and valve are designed for an operation range at a 90 °, so they are primarily used for switchover between different users or generators of energy or as a shut-off element. There are sets available, with valve dimensions from DN15-DN40. Actuators can be also quipped with an auxiliary switch to control additional element. - Integrated "click" permanent clutch for manual movement. - Extremely easy and quick installation. - Built-in turning direction indicator. - Valve position indication. - Perfect sealing of the valve. - Suitable for use in heating systems as well as in domestic hot water systems. - Specially designed valve reduces resistance and pressure drop. Description of settings buttons 1 - LED display - rotating the valve to left. 3 - LED display - Rotating valve to right. 4 - Manual movement button. 5 - Clutch for manual movement.
Open the catalog to page 1Technical Data Sheet Actuators AVD with ball valves Typical application AVDRS + AVDRS + Ball valve 2W Ball valve 3W Switchover from a solid fuel boiler to an oil boiler — • Switchover from a solid fuel boiler to a gas boiler — • Switchover of the storage tank to an oil boiler — • Switchover of the storage tank to a gas boiler — • Switchover between a solid fuel boiler and a solar system (domestic hot water heating) — • Switchover between an oil boiler and a solar system (domestic hot water heating) — • Switchover of the heat pump and the solar system (domestic hot water heating) — • Switchover...
Open the catalog to page 2Outlined functions Signalization of operation The signalization of operation with LEDs on the actuator shows the direction in which the mixing valve is moving. The user always has an overview whether the actuator is stationary or moving. Manual mode clutch Clutch for manual movement on actuator AVD is activated by pressing button . Activation of clutch is signaled with LED light. Four possible installation positions The AVD actuators can be installed on the ball valve in four positions (Up, down, left, right). Quick installation Innovative mounting set and way of installation allows quick mounting...
Open the catalog to page 3Technical Data Sheet Actuators AVD with ball valves Technical specifications for actuator Connection voltage Auxiliary pump OFF switch Degree of protection Safety class IP 42 II for the voltage of 230 V~, III for the voltage of 24 V~/V= Used standards Housing material Standard cable length Operating temperature Storage temperature Product weight No. of pieces in the packaging unit Electrical connection Seltron d.o.o. | Tržaška cesta 85 A | SI-2000 Maribor | +386 (0)2 671 96 00 | [email protected] | www.seltro
Open the catalog to page 4Working mode Working temperature Working angle Connection size Kvs Order code DescriptionTwo-point actuator AVD05RS - with an end-limit switch + shutoff ball valve - set 1AVD05B3021215-0 Actuator SELTRON AVD05RS, 30 s, 230 V~, + 2W ball valve 1/2" 1AVD05B3021220-0 Actuator SELTRON AVD05RS, 30 s, 230 V~, + 2W ball valve 3/4" 1AVD10B1M21225-0 Actuator SELTRON AVD10RS, 1 min, 230 V~, + 2W ball valve 1" 1AVD15B1M21232-0 Actuator SELTRON AVD15RS, 1 min, 230 V~, + 2W ball valve 5/4" 1AVD05B3021315-0 Actuator SELTRON AVD05RS, 30 s, 230 V~, + 3W ball valve 1/2" 1AVD10B1H21320-0 Actuator SELTRON AVD10RS,...
Open the catalog to page 5March 2023. We reserve the right to make changes due to printing errors or technical modifications. Images are symbolic. Seltron d.o.o. Tržaška cesta 85 A SI-2000 Maribor Slovenia