Basic Features
  • Process connection: VARIVENT DN 50
  • Protective fitting with neck pipe
  • Changeable connecting head and measuring element without opening the process
  • Optional integrated measuring transducer with 4...20 mA output
  • Optional calibration certificate according to DIN ISO 9000 ff
Technical Features
  • 1 or 2 x Pt100, class A
  • Protective fitting: Ø 8 mm, tapered to 6 mm, material no. 1.4571 (V4A)
  • Length of immersion: 35 mm
  • Extension neck length: 70 mm
  • Connecting head: aluminum/high-grade steel with bolting or M12-plug
  • Standard functional range: -50°C to 400°C (other ranges on request)
  • Protection class: execution-dependent
  • Operating pressure: 10 bar max
Applications
  • Temperature measurement in brewing and food industry
  • Temperature measurement in pharmaceutical industry
  • Temperature measurement in positive pressure and under-inflation containers and pipings
Specialty

The process-sided protective fitting and process connection Varivent DN 50 are manufactured in one piece without welding seam, ensuring better aseptic conditions.

Pin Assignment for M12-plug
  • With measuring transducer MUK: Black (-24 V), Brown (+24 V)
  • Without measuring transducer MUK: Black, Brown, White, Blue (Pt100)
Order Code
  • Connecting head options range from SB (IP54) with screw-cap to SBVASTH (high-grade-steel, IP65, M12-plug)
  • Type of sensor and tolerance options include 1xPt100, class A 4-wire and 2xPt100, class A 3-wire
  • Output signal and additional name for integrated sensor-head transducer MUK
  • Specification of the temperature range
See more

Catalog excerpts

Type TF 16-1

temperature measurement modular @ temp Resistance thermometer for aseptic applications (brewing technology) Basic features ► s connection VARIVENT DN 50 ► :ive fitting with neck pipe ► 3 able connecting head ► 3 able measuring element (without opening the process) ► 31: with free programmable integrated measuring transducer 4...20 mA ► l: calibration certificate according to DIN ISO 9000 ff (see data sheet calibr.-service) v___y ► :ive fitting 0 8 mm, tappered to 6 mm, material no. 1.4571 (V4A) ► of immersion: 35 mm ► ion neck length: 70 mm ► gh-grade-steel connecting head with bolting or M12-plug ► rd-functional range -50°C to 400 °C (other ranges on request) ► ion class: (execution-dependently) ► 'ature measuring in the brewing and food industry ► ature measuring in the pharmaceutical industry ► ature measuring in positive pressure- and under-inflation containers and pipings Process-sided protective fitting and process connection Varivent DN 50 are manufactured in one piece (without welding seam), therefore a better aseptic is ensured. Pin assignment M12-plug With measuring transducer MUK Without measuring transducer MUK Black Black Bue Order Code lutput signal Additional name for integrated sensor-head transducer MUK Specification of the temperature range seli GmbH Automatisierungstechnik • DieselstraBe 13 • 48485 Neuenkirchen • Tel. 05973 / 9474-0 • Fax 05973 / 9474-74 • E-Mail [email protected] • Intern

 Open the catalog to page 1

All Seli GmbH Automatisierungstechnik catalogs and technical brochures

  1. SDT 03

    3  Pages

  2. Type TF 48

    1  Page

  3. Tyep SFP-S

    2  Pages

  4. Typ TF 19

    1  Page

  5. Type TF 15

    2  Pages

  6. Type TF 14

    2  Pages

  7. Type SDA-2000

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.