MFM383A
1 /2Pages

MFM383A

MFM383A
1 /2Pages

Catalog excerpts

MFM383A-1

Multifunction Meter 3Ø True RMS (Voltage, Current) 3Ø Power (Active, Reactive & Apparent) Energy (Active, Reactive & Apparent) Programmable CT / PT Primary / Secondary Modbus RTU Communication (RS485) (Optional) Single pulse output Display specications Output Specications 3 rows, LCD with Backlight Lowest 7½ digit for energy display Input specications Pulse output Voltage range : External 24V DC max Current capacity : 100mA max Pulse width : 100ms ±5ms Communication interface and protocol Communication address Electrical connection Transmission mode Half duplex Input voltage range Transmission distance Transmission speed Input current range Display scrolling Automatic / Manual Stop bits Power consumption Response time 100ms (Max and independent of baud rate) Display reset For energy : 0.1k, 1k (depending upon CT ratio x PT ratio) For power, Voltage, Current : Auto resolution For Power Factor : 0.001 Voltage (L - N / L - L) : ±0.5% of F.S. Current : ±0.5% of F.S. Power factor : ±0.01 Frequency : ±0.1% For L - N Voltage >20V For L - L Voltage >35V Power (Active, Reactive, Apparent) : 1% Energy (Active, Reactive, Apparent) : Class 1 Memory retention Measuring parameters Voltage (L - L / L - N) (Individual / Average), Current (Individual / Average), Frequency, Power Factor (Individual / Total), Active, Reactive & Apparent Power (Individual / Total), Active, Reactive & Apparent Energy (Total) Auxiliary supply specications Supply voltage Settable parameters CT Primary 1 / 5A upto 10kA (Programmable for any value) Environmental specications Temperature Operating temperature : -10º to 55ºC Storage temperature : -20º to 75ºC Mechanical specications

 Open the catalog to page 1
MFM383A-2

Multifunction Meter Applicable EMI / EMC Standards Product Standard : IEC 61326 - 1 Category Side view Panel cutout Front bezel valid for communication model only ESD Immunity Surge immunity Radiated susceptibility Level III, 80 to 1000MHz (10V / m) IEC 61000 - 4 - 3 Level II, 1.4GHz to 2GHz (3V / m) Level I, 2GHz to 2.7GHz (1V / m) Conducted susceptibility Voltage dips and interruptions Dips : 0% residual voltage / 1 cycle (Criteria B), 40% residual voltage / 10 cycles 50Hz / 12 cycles 60Hz (Criteria C) 70% residual voltage / 25 cycles IEC 61000 - 4 - 11 50Hz / 30 cycles 60Hz (Criteria C) Interruptions...

 Open the catalog to page 2

All SELEC Controls Pvt. Ltd. catalogs and technical brochures

  1. MA12

    2  Pages

  2. MFM376-C-CE

    2  Pages

  3. MFM284

    2  Pages

  4. MFM384-R-C

    2  Pages

  5. Product Catalog

    48  Pages

  6. EM4M

    2  Pages

  7. 55ES

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.