MA12
1 /2Pages

MA12

MA12
1 /2Pages

Catalog excerpts

MA12-1

Ammeter - Digital Display Specifications 4 Digit, 7 segment LED Display True RMS Measurement For 1 Phase 2 Wire Electrical Network CT Primary Programmable upto 4000A C Mechanical Specifications Panel mount Digit Height Display Range Input Specifications Electrical Connection Input Current Range Continuous Max. Input Current Overrange Indication Frequency Range 0.001, 0.01, 0.1, 1A (Depending upon CT primary ±0.5% of F.S (CT primary / shunt setting) Standards Compliance Level IV (Air discharge : 15kV), (Contact Discharge : -8kV) Surge Immunity +/- 2kV common mode, (Line to ground) +/- 1kV differential mode, (Line to Line) Radiated Susceptibility Level III, 80 to 1000MHz (10V/m) Level II, 1.4GHz to 2GHz (3V/m) Level I, 2GHz to 2.7GHz (1V/m) Conducted Susceptibility Dips : 0% residual voltage / 1 cycle (Criteria B), 40% residual voltage / 10 cycles 50Hz / 12 cycles 60Hz (Criteria C) 70% residual voltage / 25 cycles IEC 61000-4-11 50Hz / 30 cycles 60Hz (Criteria C) Interruptions : 0% residual voltage / 250 cycles 50Hz / 300 cycles 60Hz (Criteria C) Input Burden Sampling Rate Dielectric withstand Voltage 2kV AC between auxiliary supply & measuring input Rated Impulse withstand Voltage Voltage Dips and Interruptions Auxiliary Supply Conducted Emission Supply Frequency Power Consumption Auxiliary Supply Specifications Settable Parameters Front bezel Side view Radiated Emission Electrical Fast Transient Panel cutout Environmental Specifications Temperature Humidity (non-condensing)

 Open the catalog to page 1
MA12-2

Ammeter - Digital Ordering Information Terminal Connections Supply Voltage Product Code Cable Size (AWG): 20 to 14 ; Tightening Torque (Lb-inch): 6.018 to 6.992 2 Cable Size (mm ): 0.5 to 2.5 ; Tightening Torque (N-m): 0.68 to 0.79 # AC Models (Direct Type#) N Note: 1) CT Type : There is an internal CT with CT setting (5-4000A). For current input >5A, external CT is required. 2) Direct Type : Input is directly connected to the unit. 1) CT Type: There is an internal CT with CT setting. Above 5A(0-5A model) external CT is required. 2) Direct Type: Input is directly connected to the input of the...

 Open the catalog to page 2

All SELEC Controls Pvt. Ltd. catalogs and technical brochures

  1. MFM376-C-CE

    2  Pages

  2. MFM284

    2  Pages

  3. MFM384-R-C

    2  Pages

  4. MFM383A

    2  Pages

  5. Product Catalog

    48  Pages

  6. EM4M

    2  Pages

  7. 55ES

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.