Control and Measuring Instruments
Open the catalog to page 1Single and twin-parameter control instruments The Kontrol 500-series are advanced controllers designed for high-end applications. The units feature independent proportional PID-enabled control outputs, RS 485 serial port with MODBUS protocol, USB port on request, probe quality checking, a variety of outputs and full data logging capability. The user has full programming authority. l pH / ORP l Conductivity l Dissolved Oxygen l Chlorine l Chlorine Dioxide l Hydrogen Peroxide l Ozone l Peracetic Acid l Turbidity l Suspended solids Applications l Waste Water l Drinking Water l Cooling Towers l...
Open the catalog to page 2Measure range Code Data logging Internal Flash Memory with records interval from 1 to 99 min. (near to 16000 records) Visualization key for stored data in tabular and graphic form. Type: Circular (F.I.F.O.) or Filling. Inductive Conductivity Dissolved Oxygen Chlorine and Chlo. Dioxide RS485 Serial port To set-up and to acquire/capture real time data or to download stored data on PC or laptop (Communication Software Master Controller NET required). MODBUS RTU communication protocol Hydrogen Peroxide Peracetic Acid Suspended Solids Turbidity USB port To download recorded data on removable...
Open the catalog to page 3Single-parameter control The Kontrol 200-series are advanced controllers designed for simpler high-end applications. The units feature an independent proportional control output, probe quality checking and a variety of outputs . The user has full programming authority. • Dissolved Oxygen • Chlorine Dioxide • Hydrogen Peroxide • Peracetic Acid • Drinking Water • Cooling Towers • Legionella disinfection • Reverse Osmosis • Crate Wash • Galvanic Process • Dioxide Station • Swimming Pool • Fish Farming Graphic display and Keypad monochrome display with graphic icons to show digital output...
Open the catalog to page 4Measure range Code Manual controls The user-friendly programming step menu makes starting up and checking the control and dosing system easy. Inductive Conductivity Measure Input High measuring resolution with probe quality control. A modular measuring system Chlorine measure in sea water application. Dissolved Oxygen Chlorine and Chlo. Dioxide Hydrogen Peroxide Peracetic Acid Digital Input Dedicated to disable all controller output functions Current outputs 4÷20mA Galvanic isolation One independent programmable Output Measures. Relay Outputs Four independent relais, two set points, one...
Open the catalog to page 5Kontrol 800 Multi-parameter control instrument The Kontrol 800 is a dedicated multi-parameter controller for complex applications that require a number of chemical parameters to be checked at the same time. The unit features independent proportional control output measures, two programmable frequency outputs, RS 485 serial port with MODBUS protocol, three relais outputs, probe quality checking and Data logging capability. l pH / ORP l Conductivity l Chlorine l Chlorine Dioxide Applications l Waste Water l Drinking Water l Cooling Towers l Boiler l Legionella disinfection l Reverse Osmosis l...
Open the catalog to page 6Measure range Code RS485 Serial port For set-up and real-time data acquisition from remote or for stored data download on PC or laptop (Communication software Sekonet required). MODBUS RTU communication protocol. Chlorine (Amperometric Cell) Chlorine and Chlo. Dioxide Measure Input High measuring resolution with probe quality control. Modular measuring system. Chlorine measure in sea water application. Digital Input Double channel, Voltage Input and Reed level input to disable all function controller output. Current outputs 4÷20mA Galvanic isolation Two (2) programmable Output Measure....
Open the catalog to page 7Photometer System Photometer Light Photometer System Multi parameter photometer instrument Photometer System The Seko Photometer System is a DPD reference point for Chlorine control. The combination of water sampling and reagents ensure maximum measurement precision. The unit itself is a compact miniature analysis laboratory dedicated to Chlorine measurement. Parameters l pH / ORP l Free and Total Chlorine l Combined Chlorine by software Applications l Waste Water l Drinking Water l Boiler l Legionella disinfection l Crate Wash l Dioxide Station l Irrigation l Swimming Pool l Sea water...
Open the catalog to page 8Measure range Internal data logger 4 Mbit flash memory equal to 16000 records Recording interval 00:00 to 99:99 min Type: circular / fill Display: table / graph (1 for each parameter). Analogue outputs 1 for each measured parameter (excluding comb. chlorine) Type: 0.00 / 4.00 to 20.00 mA Galvanically isolated Programming limit: lower / upper / reverse Maximum load: 500 Ohms - Alarm output NAMUR compliant 2.4 mA (with 4÷20 mA range) PID control function can be activated on the pH output Set point relay outputs Two (2) for Primary measure + for pH measurement (only mod. 4001-3) Programming...
Open the catalog to page 9Single and multiple-parameter control instruments The Kontrol 40 and 42 are single and multiple-parameter controllers respectively. These very user-friendly systems combine advanced performance and simple design. Single-parameter units are available in four different casings, ensuring perfect fit at the right price. l pH / ORP l Conductivity l Chlorine l Chlorine Dioxide l Flow Rate Applications l Waste Water l Drinking Water l Cooling Towers l Boiler l Legionella disinfection l Reverse Osmosis l Crate Wash l Galvanic Process l Dioxide Station l CIP l Irrigation l Swimming Pool l Sea water...
Open the catalog to page 10Measure range Code Manual controls The user-friendly programming step menu makes starting up and checking the control and dosing system easy. Chlorine (Amperometric Cell) Measure Input High measuring resolution with probe quality control. Modular measuring system Chlorine measure in sea water application Chlorine and Chlo. Dioxide (Potentiostatic Cell) Flow Rate (*) Setting by software following unit measures: l/s, l/h, m³/h, GPM. Digital Input Voltage Input to disable all function controller output. Current outputs 4÷20mA Galvanic isolation One(1) programmable measurement output. Relay...
Open the catalog to page 11All SEKO catalogs and technical brochures
-
Kompact
4 Pages
-
Tekna Series
8 Pages
-
Kitchen
20 Pages
-
Process & Systems
8 Pages
-
Tekba
4 Pages
-
Water Treatment
8 Pages
-
SekureMax
4 Pages
-
WashSeries
4 Pages
-
Kronos
4 Pages
-
Tekna EVO TCK series
4 Pages
-
Tekna EVO ATL series
4 Pages
-
Tekna EVO TPG series
4 Pages
-
Maxima PLUS MRP series
4 Pages
-
Maxima PLUS MGR series
4 Pages
-
Surface cleaning systems
20 Pages
-
Laundry dosing systems
20 Pages
-
Kitchen dosing systems
20 Pages
-
Chemical Injection Packages
8 Pages
-
HN Nexa Series
8 Pages
-
Polimer preparation units
6 Pages
-
Flow Level and Pressure
20 Pages
-
Swimming pool Equipment
36 Pages
-
Invikta Series
4 Pages
-
Kompact Series
4 Pages
-
Maxima EVO
4 Pages
-
Maxima Plus
4 Pages
-
Dynamik Series
6 Pages
-
Twindose 40 EVO
2 Pages
-
Drain Plus
2 Pages
-
Tekna Evo 500
1 Pages
-
SWE Exacta Series
8 Pages
-
E Exacta Series
8 Pages
-
Motor Driven METERING PUMPS
16 Pages
-
Nexa Series
8 Pages
-
KN Nexa Series
4 Pages
-
WS Exacta Series
8 Pages
-
D Exacta Series
6 Pages
-
HN Nexa Series
4 Pages
-
TN Nexa Series
4 Pages
-
YN Nexa Series
4 Pages
-
3C TRIPLEX Exacta Series
8 Pages
-
K Exacta Series
8 Pages
-
Tekna EVO Series
12 Pages
-
PN Nexa Series
4 Pages
-
Solenoid metering pumps
4 Pages
-
Peristaltic dosing pumps
4 Pages
-
Motor driven metering pumps
16 Pages
Archived catalogs
-
Filters
16 Pages