Specifications:
The RECUSORB R-060BR dehumidifier features built-in heat recovery, low dry air temperature, and a long lifetime. It includes a washable rotor and a stainless steel chassis. The dehumidifying capacity at 20°C and 60% relative humidity is 4.6 kg/h, with a dry air flow of 1000 m³/h. The rotor from Seibu Giken is designed with a high number of channels for efficient moisture adsorption.

Technical Data:
Nominal capacity is 4.6 kg/h, with a dry air flow of 1000 m³/h and a static pressure at disposal of 200. The wet air flow is 250 m³/h with a static pressure at disposal of 50. The heater power is 6 kW, and the maximum electric consumption is 6.4 kW. The supply fuse is rated at 3 x 230/400V 50Hz, 25/16 A. The unit weighs 63 kg.

Procedures:
The temperature of the dry air at nominal air flows is calculated using the formula: tout = tin + (K x 10) + 5. The dehumidifying capacity can be adjusted for different inlet conditions using a correction factor from the provided diagram.

Recommendations:
For optimal performance, refer to the correction diagram for capacity adjustments under varying conditions. Ensure proper installation by downloading the installation drawing from the provided website.

Contact Information:
Seibu Giken DST AB, Avestagatan 33, SE-163 53 Spånga, Sweden. Tel: +46 8 445 77 20, Fax: +46 8 445 77 39, Website: www.dst-sg.com, Email: [email protected]
See more

Catalog excerpts

Dehumidifier R-060BR-1

RECUSORB R-060BR Dehumidifying capacity at 20°C / 60%RH 1000 m³/h Built-in heat recovery Low dry air temperature Long lifetime Washable rotor No desiccant carry-over Stainless steel chassis Section of a dehumidifier rotor from Seibu Giken. The high number of channels means that moisture is adsorbed with extra efficiency!

 Open the catalog to page 1
Dehumidifier R-060BR-2

TECHNICAL DATA Dehumidifier model Static pressure at disposal Static pressure at disposal Maximum electric consumption (kW) Wet air Regen. air Dry air Rotor motor Valid for inlet conditions 20°C/ 60%RH. For other inlet conditions the capacity can be calculated by using the correction factor from the diagram shown below Volume flow for density 1.20 kg/m3. Volume flow for density 1,20 kg/m3. Freeblowing. CORRECTION DIAGRAM The temperature of the dry air at nominal air flows is calculated by: tout = tin + ( K x 10) + 5 The dehumidifying capacity is estimated as the nominal capacity from above, multiplied...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.