Overview: The Dehumidifier Recusorb models DR-20B and DR-30D are designed with a washable rotor, protected control panel, stainless steel chassis, self-regulating heater, and a fold-flat handle for easy transport. These features contribute to a long lifetime and easy maintenance, including accessible filters.
Specifications:
  • Dehumidifying capacity at 20°C / 60%RH: 0.8 - 1.1 kg/h
  • Dry air flow: 330 - 360 m³/h
  • Wet air flow: 60 - 75 m³/h
  • Heater current: 4.5 - 6.5 A
  • Maximum electric consumption: 1.2 - 1.7 kW
  • Supply fuse: 230V / 50Hz, 10 A
  • Weight: 15 - 17 kg
Technical Details: The dehumidifying capacity is calculated using a correction factor from a diagram for different inlet conditions. The PTC heater design allows power regulation by controlling wet air flow. The temperature of the dry air at nominal air flows is calculated with specific formulas for each model.
Design Features: The rotor section from Seibu Giken features a high number of channels for efficient moisture adsorption. The unit includes a process air fan, heater, rotor motor, and designated outlets for dry and wet air.
Additional Information: The document notes that specifications are subject to change without notice and provides contact information for Seibu Giken DST AB in Sweden. Installation drawings can be downloaded from their website.
See more

Catalog excerpts

Dehumidifier DR-20B-30D-1

Dehumidier Recusorb 330 - 360 m³/h Washable rotor Protected control panel Stainless steel chassis Self-regulating heater Fold-at handle Long lifetime Easy access to lter Section of a dehumidier rotor from Seibu Giken. The high number of channels means that moisture is adsorbed with extra efciency!

 Open the catalog to page 1
Dehumidifier DR-20B-30D-2

Heater Rotor Maximum electric consumption (kW) TECHNICAL DATA Dehumidier model Fan Rotor motor Process air Valid for inlet conditions 20°C/ 60%RH. For other inlet conditions the capacity can be calculated by using the correction factor from the diagram shown below. Volume ow for density 1.20 kg/m³. Free blowing. CORRECTION DIAGRAM The design of the PTC heater enables the power to be regulated by controlling the wet air ow. The temperature of the dry air at nominal air ows is calculated by: DR-30:tout = tin+ ( K x 10 ) + 3°C DR-20:tout = tin+ ( K x 7 ) + 3°C The dehumidifying capacity is estimated...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.