Overview: The Aquasorb A-30B/Bp dehumidifier is designed for efficient moisture removal, operating effectively at dew points below 0°C. It features a washable rotor and a stainless steel chassis, with an optional dry air connection.
Specifications:
  • Dehumidifying capacity: 0.5 kg/h at 20°C / 60% RH
  • Dry air flow: 400 m³/h
  • Static pressure: 0 Pa for A-30B, 200 Pa for A-30Bp
  • Heater power: 1 kW
  • Maximum electric consumption: 1.20 kW for A-30B, 1.22 kW for A-30Bp
  • Supply fuse: 230V / 50Hz, 10 A
  • Weight: 32 kg
Features:
  • Includes a trolley, condensate collector, and dry air spigot
  • Control equipment for efficient operation
  • High-efficiency moisture adsorption due to a high number of rotor channels
Technical Data: The dehumidifying capacity can be adjusted using a correction factor based on inlet conditions. The temperature of the dry air is calculated by adding 9°C to the inlet temperature.
Diagram and Calculations: A correction diagram is provided to adjust the dehumidifying capacity for different inlet conditions. The nominal capacity is multiplied by a factor K from this diagram.
Contact Information: Seibu Giken DST AB, Avestagatan 33, SE-163 53 Spånga, Sweden. Tel: +46 8 445 77 20, Fax: +46 8 445 77 39, Website: www.dst-sg.com, Email: [email protected]
See more

Catalog excerpts

Dehumidifier A-30B/Bp-1

Dehumidifier Aquasorb 400 m³/h Washable rotor Dry air connection (optional) Operates at dew-points below 0°C Condenses out the moisture Stainless steel chassis All energy accumulates in the dry air Useful options: Trolley Condensate collector Dry air spigot Control equipment Section of a dehumidifier rotor from Seibu Giken. The high number of channels means that moisture is adsorbed with extra efficiency!

 Open the catalog to page 1
Dehumidifier A-30B/Bp-2

Static pressure at disposal (Pa) TECHNICAL DATA Dehumidifier model Maximum electric consumption (kW) Rotor Rotor motor Condensate outflow 1 Valid for inlet conditions 20°C / 60% RH. For other inlet conditions, the capacity can be calculated by using the correction factor from the diagram shown below. 2 Volume flow for density 1.20 kg/m³. CORRECTION DIAGRAM The temperature of the dry air at nominal air fl ows is calculated by: tout = tin + 9 The dehumidifying capacity is estimated as the nominal capacity from above, multiplied by factor K from the correction diagram. Dry air outlet (A-30Bp Ø125)...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.