USB Deviceserver INU-100

USB Deviceserver INU-100
1 / 122 PagesView full catalog

USB Deviceserver INU-100

Product catalog summary
Product Overview
The INU server integrates non-network-ready USB devices into an industrial environment via a TCP/IP network, using the SEH UTN Manager to establish a virtual USB connection. It is compatible with Windows, macOS, and Linux systems and requires an IPv4 TCP/IP network. The server can be combined with SEH products like the IH-304 USB Hub and SU-302 Serial to USB Converter for enhanced functionality.
Documentation and Administration
Documentation includes a Hardware Installation Guide, Quick Installation Guide, User Manual, and online help. Administration can be performed via the INU Control Center, SEH UTN Manager, or email. The INU Control Center is accessible through a web browser, while the SEH UTN Manager is a software tool for managing USB device connections.
Network and Device Settings
Instructions are provided for configuring IPv4/IPv6 parameters, DNS, SNMP, Bonjour, and email settings. Device settings include configuring device time, assigning descriptions, managing USB ports, and using the relay.
Security Features
The document details encrypting USB connections, defining SSL/TLS encryption strength, and controlling access to the INU Control Center and USB devices. It recommends using high encryption levels and warns against outdated protocols.
Maintenance Procedures
Instructions for restarting the INU server, updating, backing up configurations, and resetting parameters are included. The document also covers troubleshooting tips and parameter lists.
Support and Safety
SEH Computertechnik GmbH provides extensive support for their products. Users must read and observe all safety regulations to avoid misuse and prevent damage. The INU server is designed for use in TCP/IP networks within industrial environments.
Initial Setup and Administration Methods
Initial setup involves reading security regulations, installing hardware and software, configuring the INU server, and using the SEH UTN Manager to manage USB device connections. Administration via email allows remote access to server status and parameter settings.
SEH UTN Manager
The SEH UTN Manager is available in complete and minimal versions, with the complete version recommended for general use. It supports IPv4 networks and requires administrative rights for certain features.
Specifications and Setup Requirements
The document outlines the configuration and administration of an INU server, focusing on email communication, network settings, and protocol configurations. Key specifications include the setup of a DNS server on the INU server and configuration of POP3 and SMTP parameters.
Network Configuration
Detailed instructions are provided for configuring IPv4 and IPv6 parameters, DNS, SNMP, and Bonjour settings. Recommendations include disabling DHCP, BOOTP, and ARP/PING once an IP address is assigned to enhance security.
SMTP Configuration and Security
The document outlines the configuration of SMTP settings for the INU server, including the necessity of SMTP authentication to prevent spam. It details parameters such as SMTP user name and password, and the use of S/MIME for email security.
VLAN Configuration
The INU server supports VLANs according to 802.1Q, allowing for network segmentation and security. Procedures for defining IPv4 Management and Client VLANs are provided.
Device Settings and Notifications
This section covers configuring device time via an SNTP server, assigning descriptions and names to devices and USB ports, and disabling USB ports to prevent unauthorized access. The INU server can send status emails and event notifications via email or SNMP traps.
Relay Usage
The document describes how to use the relay integrated into the INU server for various purposes, such as switching devices remotely or displaying device status and events.
Authentication Protocols
The document provides detailed instructions on configuring authentication protocols and maintaining the INU server. It covers various EAP methods for secure network access.
Maintenance Procedures
Maintenance procedures include restarting the INU server, updating firmware/software, backing up configurations, and resetting parameters.
Appendix
Includes a glossary, troubleshooting guide, and parameter lists. Troubleshooting covers common issues like connection problems and BIOS mode indications.
See more

Catalog excerpts

USB Deviceserver INU-100-1

Industrial Network Unit INU User Manual Linux USB Deviceserver INU-100

 Open the catalog to page 1
USB Deviceserver INU-100-2

Manufacturer & Contact SEH Computertechnik GmbH Suedring 11 33647 Bielefeld Germany Phone: +49 (0)521 94226-29 Fax: +49 (0)521 94226-99 Support: +49 (0)521 94226-44 Email: [email protected] Web: https://www.seh-technology.com Document Type: User Manual Title: INU User Manual Linux Version: 1.2 | 2021-07 Legal Information SEH Computertechnik GmbH has endeavored to ensure that the information in this documentation is correct. If you detect any inaccuracies please inform us at the address indicated above. SEH Computertechnik GmbH will not accept any liability for any error or omission. The information...

 Open the catalog to page 2
USB Deviceserver INU-100-3

INU User Manual Linux

 Open the catalog to page 3
USB Deviceserver INU-100-4

INU User Manual Linux 6.8 6.9

 Open the catalog to page 4
USB Deviceserver INU-100-5

INU User Manual Linux General Information Product  2 Documentation  4 Support and Service  5 Your Safety 

 Open the catalog to page 5
USB Deviceserver INU-100-6

INU User Manual Linux General Information 1.1 Product Purpose INU servers integrate non-network-ready USB devices (e.g. USB sensors, USB cameras, etc.) into an industrial environment via TCP/IP network. For this purpose, the USB devices will be connected to the USB ports of the INU server. Then the UTN (UTN = USB to Network) functionality and the corresponding software tool 'SEH UTN Manager' establish a virtual USB connection between USB device and client. The USB device can be used as if it were connected locally. In addition, a load can be connected to and then used via the relay of the INU...

 Open the catalog to page 6
USB Deviceserver INU-100-7

INU User Manual Linux General Information Combination with Associated Products You can combine the INU server with additional SEH Computertechnik GmbH products to ideally adapt the use of your devices to your environment! Industrial Solution 'IH-304 USB Hub' The industrial solution IH-304 is a USB hub with four USB 3.0 ports. If it is connected to the INU server, up to four USB devices can be used per INU server USB port. This is a most efficient solution for control cabinets with little space. The IH-304 must be purchased separately. Detailed information: https://www.seh-technology.com/products/industrial-solutions/ih-304.html...

 Open the catalog to page 7
USB Deviceserver INU-100-8

INU User Manual Linux General Information 1.2 Documentation Please load all current documents from our Website: https://www.seh-technology.com Further applicable documents Thee INU documentation consists of the following documents: Hardware Installation Guide Quick Installation Guide User Manual Online help Information on safety, technical data, hardware installation and declarations of conformity Description of initial setup Detailed description of the INU server configuration, administration and maintenance. System-specific instructions for the following systems: - Windows - macOS - Linux Information...

 Open the catalog to page 8
USB Deviceserver INU-100-9

INU User Manual Linux General Information 1.3 Support and Service SEH Computertechnik GmbH offers extensive Support. If you have any questions, please contact us. Monday through Thursday Friday +49 (0)521 94226-44 [email protected] Customers from the United States of America (USA) and Canada please contact North American Support: Monday – Friday +1-610-933-2088 [email protected] All information and downloads regarding your product is available on our website: https://www.seh-technology.com

 Open the catalog to page 9
USB Deviceserver INU-100-10

INU User Manual Linux General Information 1.4 Your Safety Read and observe all safety regulations and warnings found in the documentation, on the device and on the packaging. This will avoid potential misuse and prevent damages to people and devices. Intended Use The INU server is used in TCP/IP networks and has been designed for use in industrial environments. It allows network users to access non-network-ready USB devices. In addition, a load can be connected to and then used via the relay of the INU server. Improper Use All uses of the device that do not comply with the functionalities described...

 Open the catalog to page 10
USB Deviceserver INU-100-11

INU User Manual Linux General Information 1.5 First Steps 1. Read and observe the security regulations in order to avoid damages to people and devices  6. 2. Install the hardware. The hardware installation includes connecting the INU server to the network, USB devices, and power grid  ‘Hardware Installation Guide‘. 3. Install the software. The software installation includes installing the required software tool 'SEH UTN Manager' on your client and assigning an IP address  ‘Software Installation Guide‘. 4. Configure the INU server so that it is optimally embedded it into your network and...

 Open the catalog to page 11
USB Deviceserver INU-100-12

INU User Manual Linux Administration Methods 2 Administration Methods You can administer, configure and maintain the INU server in a number of ways: • Administration via INU Control Center  9 • Administration via the SEH UTN Manager  11 • Administration via Ema

 Open the catalog to page 12
USB Deviceserver INU-100-13

INU User Manual Linux Administration Methods Administration via INU Control Center The INU server has a user interface, the INU Control Center which can be opened in an Internet browser (e.g. Mozilla Firefox). The INU server can be configured, monitored and maintained via the INU Control Center. • Open INU Control Center in Browser  9 • INU Open Control Center via SEH UTN Manager  9 • Controls  10 Open INU Control Center in Browser  The INU server is connected to the network and the power grid.  The INU server has a valid IP address  21. 1. Open your browser. 2. Enter the IP address...

 Open the catalog to page 13
USB Deviceserver INU-100-14

INU User Manual Linux Administration Methods Menu item Submenu items Page Product & Company Sitemap Flags ? icon After selecting a menu item (simple mouse click), the available submenu items are displayed to the left. After selecting a submenu item, the corresponding page with its content is displayed. Menu content Manufacturer’s contact details and additional product information. Overview of and direct access to all pages of the INU Control Center. Language selection Online help

 Open the catalog to page 14
USB Deviceserver INU-100-15

INU User Manual Linux Administration Methods The 'SEH UTN Manager' is a software tool developed by SEH Computertechnik GmbH. The SEH UTN Manager is used to establish and manage connections to the USB devices connected to the INU servers. • Features  11 • Versions  13 • Installation  13 • Program Start  17 Features The software is installed on all clients that are meant to access a USB device in the network. After the SEH UTN Manager is started, the network is scanned for connected INU servers. All INU servers found and their connected USB devices are displayed in the 'network list'. To...

 Open the catalog to page 15

All SEH Computertechnik catalogs and technical brochures

  1. TPG-125

    28  Pages

  2. SU-302

    48  Pages

Archived catalogs

  1. NDR-75 series

    4  Pages

  2. MDR-20 series

    2  Pages

  3. Printserver

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.