SU-302

SU-302
1 / 48 PagesView full catalog

SU-302

Product catalog summary
Overview: The SU-302 is a Serial to USB converter designed for industrial use, featuring one USB 2.0 interface and two serial interfaces (RS-232 and RS-485). It can connect to a client via USB or to an industrial USB Deviceserver (INU-100) for network access, with the USB interface also supplying power.
Associated Products: Compatible with SEH Computertechnik GmbH products like the INU-100 USB Deviceserver and IH-304 USB Hub, which are mounted on a top-hat rail and require a power supply.
Scope of Supply: Includes the SU-302 converter, user manual, jumpers, snap ferrite, and USB cable.
Technical Data: Supports RS-232 and RS-485 interfaces with specific pin assignments. Operates in temperatures between 5–70°C and humidity of 20–80%. Dimensions provided for installation.
Connectors: Detailed information on RS-485 and RS-232 connectors, including pin assignments and cable requirements.
LED Display: Features LEDs indicating the status of RS-485 and RS-232 connections, power supply, and low power mode.
Safety Regulations: Users should read documentation, avoid liquid contact, and ensure the device is in perfect condition. Unauthorized modifications are prohibited, with specific cable and grounding requirements outlined.
Preparation: Users should note existing port numbers on their client system before installation. Instructions provided for Windows and Linux systems.
Hardware Installation: Install on a top-hat rail with instructions for connecting serial devices to RS-232 and RS-485 interfaces, power supply, and USB connection.
Initial Set Up: Requires driver installation on the client system, supporting various Windows and Linux versions. Instructions for identifying port numbers post-installation are provided.
Notice of Publication: Outlines standards for technical documentation under the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Regulation 2021 (S.I 2021/3032).
Standards Applied: Lists standards including EN 55035:2017 + A11:2020, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55032:2015 + A11:2020 Class B, and EN IEC 63000:2018. Compliance requires adherence to the Hardware Installation Guide.
UK Declaration of Conformity: Latest version available on SEH Computertechnik GmbH's website.
FCC Notice: Complies with FCC rules for a Class B digital device, designed to prevent harmful interference in residential installations. Specific measures advised if interference occurs.
Recycling Notes: Devices should be disposed of separately from domestic waste at local collection points, in accordance with the Electric and Electronic Equipment Act and the European directive 'WEEE'.
Manufacturer Information: SEH Computertechnik GmbH provides support and sales contact information, along with resources for downloads and open-source software inquiries.
See more

Catalog excerpts

SU-302-2

Overview This 'Quick Installation Guide' provides a description of the initial setup of the INU-100. The hardware installation is described in the 'Hardware Installation Guide'. Table of contents 1. Do you need assistance? Contact us! Monday to Thursday 8:00 a.m. to 4:45 p.m. and Friday 8:00 a.m. to 3:15 p.m. (CET) +49 (0)521 94226-44 [email protected] www.seh-technology.com Customers from the United States of America and Canada please contact the North American support. Monday to Friday

 Open the catalog to page 2
SU-302-3

Überblick Dieser 'Quick Installation Guide' beschreibt die Inbetriebnahme des INU-100. Die Hardware-Installation wird im 'Hardware Installation Guide' erklärt. Inhaltsverzeichnis 13. Benötigen Sie Hilfe? Kontaktieren Sie uns! Montag–Donnerstag 8:00–16:45 Uhr Freitag 8:00–15:15 Uhr +49 (0)521 94226-44 [email protected]

 Open the catalog to page 3
SU-302-5

 Purpose The industrial solution SU-302 is a converter which converts serial data to USB data. For this purpose, the device has one USB 2.0 interface and two serial interfaces: 1. RS-232 (for plug type D-Sub, DE-9) 2. RS-485 (also known as EIA-485; compatible with RS-422/ EIA-422) The SU-302 is connected to a client via the USB interface. Alternatively, the SU-302 can be connected to an industrial USB Deviceserver 'INU-100’ by SEH Computertechnik GmbH. This way, the serial devices which are connected to the SU302 can be accessed via a TCP/IP network or the Internet. The USB interface supplies...

 Open the catalog to page 5
SU-302-6

Industrial Solution 'IH-304 USB Hub' The industrial solution IH-304 is a USB hub with four USB 3.0 ports. Up to four USB devices such as the SU-302 can be connected to these USB ports and be used via one single USB connection. This is a most efficient solution for control cabinets with few free USB ports. The IH-304 in turn is connected to a client via the USB interface. Alternatively, the IH-304 can be connected to an industrial USB Deviceserver 'INU-100’ by SEH Computertechnik GmbH (’Industrial Solution 'INU-100 USB Deviceserver'’ 2). This way, the connected USB devices can be accessed via...

 Open the catalog to page 6
SU-302-7

Spare yourself the search and use the top-hat rail power supplies DRP-20 and DRP-75 which are specifically selected to perfectly match the industrial solutions! http://www.seh-technology.com/products/ industrial-solutions/accessories.html User Manual

 Open the catalog to page 7
SU-302-8

 Scope of Supply Please check the package content before getting started: User Manual The User Manual gives information on the installation and initial set up of the SU-302. (This document) Short-circuit bridges Snap ferrite Split core ferrite USB 2.0, type A plug and type B plug User Manua

 Open the catalog to page 8
SU-302-9

 Technical Data Device Overview RS-232 LED snap lock low power mode LED RS-485 (serial interface) USB port (type B) Properties Device connection – 1 × RS-232 (for plug type D-Sub, DE-9; signals: DCD, RXD, TXD, DTR, GND, DSR, RTS, CTS, RI) – 1 × RS-485 (also known as EIA-485; compatible with RS-422/EIA-422; signals: A, B, Y, Z; full or half duplex mode) User Manual

 Open the catalog to page 9
SU-302-10

Host connection and power supply Current input approx. 200 mA at 5 V with full load on both serial interfaces Operating environment - ambient temperature: 5–70 °C - relative humidity: 20–80 % Dimensions & Weight

 Open the catalog to page 10
SU-302-11

screw terminals: galvanic isolation: receiver: mode: A BY Z 5 kV ¼ unit load – standard = full duplex (FD); – optional: half duplex cable: – shielding: required – required stripping: approx. 7 mm – insertion: stripped end with or without end terminals – termination resistors might be required (depending on installation environment) plug type: D-Sub, DE-9 pin assignment: 1 DCD [in] 2 RXD [in] 3 TXD [out] 4 DTR [out] 5 GND 6 DSR [in] 7 RTS [out] 8 CTS [in] 9 RI [in] shield: not connected (You also find the most important information printed on the side of the SU-302 housing.) User Manua

 Open the catalog to page 11
SU-302-12

 LED Display The LEDs of the SU-302 provide information about its status. LED permanently – off flashing at green irregular intervals flashing at red irregular intervals permanently – off flashing at green irregular intervals flashing at red irregular intervals permanently – off permanently yellow on SU-302 is not supplied with power via USB. SU-302 is supplied with power via USB. permanently – off permanently green on SU-302 is in standard operating mode. USB connection is in low power mode. Data is being received. Data is being sent. Data is being received. Data is being sent.

 Open the catalog to page 12
SU-302-13

 Type Plate The type plate gives important product information, such as hardware and certification information as well as the serial number. The serial number contains the production date: nnn YYYY MM nnnnn. You need this information for support requests. User Manual

 Open the catalog to page 13
SU-302-14

 Safety Regulations The SU-302 is a data converter for use in industrial environments. The SU-302 converts serial data to USB data. • Read the documentation and make sure that your system meets the requirements listed therein. • Avoid contact with humidity or liquids. • The device must only be connected and operated if it is in perfect condition. • Do not open the housing. Unauthorized modifications to the device can affect the product certification and are forbidden. • Only use a certified USB cable (< 3 m) listed at www.usb.org. • Electrostatic discharges (ESD) may impair device performance....

 Open the catalog to page 14
SU-302-15

 Preparation If you connect a serial device to a client via SU-302, the driver installation is the first step. Then the serial interface will automatically be enumerated as port on the client. The enumeration is dynamic, i.e. the serial interface receives the next available port number. Thus it is also client-specific. The serial device will keep the port number even if it is removed occasionally but connected back to the same physical USB interface. To identify the port numbers that the serial devices connected via SU-302 receive from the client, you must note down which port numbers are already...