Overview This 'Quick Installation Guide' provides a description of the initial setup of the INU-100. The hardware installation is described in the 'Hardware Installation Guide'. Table of contents 1. Do you need assistance? Contact us! Monday to Thursday 8:00 a.m. to 4:45 p.m. and Friday 8:00 a.m. to 3:15 p.m. (CET) +49 (0)521 94226-44 support@seh.de www.seh-technology.com Customers from the United States of America and Canada please contact the North American support. Monday to Friday

Open the catalog to page 2
SU-302 - 3

Überblick Dieser 'Quick Installation Guide' beschreibt die Inbetriebnahme des INU-100. Die Hardware-Installation wird im 'Hardware Installation Guide' erklärt. Inhaltsverzeichnis 13. Benötigen Sie Hilfe? Kontaktieren Sie uns! Montag–Donnerstag 8:00–16:45 Uhr Freitag 8:00–15:15 Uhr +49 (0)521 94226-44 support@seh.de

Open the catalog to page 3
SU-302 - 5

 Purpose The industrial solution SU-302 is a converter which converts serial data to USB data. For this purpose, the device has one USB 2.0 interface and two serial interfaces: 1. RS-232 (for plug type D-Sub, DE-9) 2. RS-485 (also known as EIA-485; compatible with RS-422/ EIA-422) The SU-302 is connected to a client via the USB interface. Alternatively, the SU-302 can be connected to an industrial USB Deviceserver 'INU-100’ by SEH Computertechnik GmbH. This way, the serial devices which are connected to the SU302 can be accessed via a TCP/IP network or the Internet. The USB interface...

Open the catalog to page 5
SU-302 - 6

Industrial Solution 'IH-304 USB Hub' The industrial solution IH-304 is a USB hub with four USB 3.0 ports. Up to four USB devices such as the SU-302 can be connected to these USB ports and be used via one single USB connection. This is a most efficient solution for control cabinets with few free USB ports. The IH-304 in turn is connected to a client via the USB interface. Alternatively, the IH-304 can be connected to an industrial USB Deviceserver 'INU-100’ by SEH Computertechnik GmbH (’Industrial Solution 'INU-100 USB Deviceserver'’ 2). This way, the connected USB devices can be accessed...

Open the catalog to page 6
SU-302 - 7

Spare yourself the search and use the top-hat rail power supplies DRP-20 and DRP-75 which are specifically selected to perfectly match the industrial solutions! http://www.seh-technology.com/products/ industrial-solutions/accessories.html User Manual

Open the catalog to page 7
SU-302 - 8

 Scope of Supply Please check the package content before getting started: User Manual The User Manual gives information on the installation and initial set up of the SU-302. (This document) Short-circuit bridges Snap ferrite Split core ferrite USB 2.0, type A plug and type B plug User Manua

Open the catalog to page 8
SU-302 - 9

 Technical Data Device Overview RS-232 LED snap lock low power mode LED RS-485 (serial interface) USB port (type B) Properties Device connection – 1 × RS-232 (for plug type D-Sub, DE-9; signals: DCD, RXD, TXD, DTR, GND, DSR, RTS, CTS, RI) – 1 × RS-485 (also known as EIA-485; compatible with RS-422/EIA-422; signals: A, B, Y, Z; full or half duplex mode) User Manual

Open the catalog to page 9
SU-302 - 10

Host connection and power supply Current input approx. 200 mA at 5 V with full load on both serial interfaces Operating environment - ambient temperature: 5–70 °C - relative humidity: 20–80 % Dimensions & Weight

Open the catalog to page 10
SU-302 - 11

screw terminals: galvanic isolation: receiver: mode: A BY Z 5 kV ¼ unit load – standard = full duplex (FD); – optional: half duplex cable: – shielding: required – required stripping: approx. 7 mm – insertion: stripped end with or without end terminals – termination resistors might be required (depending on installation environment) plug type: D-Sub, DE-9 pin assignment: 1 DCD [in] 2 RXD [in] 3 TXD [out] 4 DTR [out] 5 GND 6 DSR [in] 7 RTS [out] 8 CTS [in] 9 RI [in] shield: not connected (You also find the most important information printed on the side of the SU-302 housing.) User Manua

Open the catalog to page 11
SU-302 - 12

 LED Display The LEDs of the SU-302 provide information about its status. LED permanently – off flashing at green irregular intervals flashing at red irregular intervals permanently – off flashing at green irregular intervals flashing at red irregular intervals permanently – off permanently yellow on SU-302 is not supplied with power via USB. SU-302 is supplied with power via USB. permanently – off permanently green on SU-302 is in standard operating mode. USB connection is in low power mode. Data is being received. Data is being sent. Data is being received. Data is being sent.

Open the catalog to page 12
SU-302 - 13

 Type Plate The type plate gives important product information, such as hardware and certification information as well as the serial number. The serial number contains the production date: nnn YYYY MM nnnnn. You need this information for support requests. User Manual

Open the catalog to page 13
SU-302 - 14

 Safety Regulations The SU-302 is a data converter for use in industrial environments. The SU-302 converts serial data to USB data. • Read the documentation and make sure that your system meets the requirements listed therein. • Avoid contact with humidity or liquids. • The device must only be connected and operated if it is in perfect condition. • Do not open the housing. Unauthorized modifications to the device can affect the product certification and are forbidden. • Only use a certified USB cable (< 3 m) listed at www.usb.org. • Electrostatic discharges (ESD) may impair device...

Open the catalog to page 14
SU-302 - 15

 Preparation If you connect a serial device to a client via SU-302, the driver installation is the first step. Then the serial interface will automatically be enumerated as port on the client. The enumeration is dynamic, i.e. the serial interface receives the next available port number. Thus it is also client-specific. The serial device will keep the port number even if it is removed occasionally but connected back to the same physical USB interface. To identify the port numbers that the serial devices connected via SU-302 receive from the client, you must note down which port numbers are...

Open the catalog to page 15
SU-302 - 16

Linux In Linux serial devices connected via a serial to USB converter such as the SU-302 are enumerated as ttyUSB port. 1. Search the folder /dev for files with 'ttyUSB' in their name. 2. Note down the result. If no devices are connected, no files exist. Take a screenshot and save or print it. User Manual

Open the catalog to page 16