Catalog excerpts
Measuring people’s safety wide opportunities for determining gas capacity of gas, vapour and combined filters Test equipment DYNAMICS using 9 gas, 4 vapor and hydrargyrum APPLICATIONS & INDUSTRIES ● Gas, vapour and combined filters ● Industrial & fire safety, emergency protec on ● RPE cer fica on, research and design For developers and manufacturers of respiratory protective equipment (RPE) For certification bodies and testing laboratories
Open the catalog to page 1DESCRIPTION Test equipment «Dynamics» prepares the gas-vapor-air mixture in accordance with the condi ons for using the filter - the required temperature, rela ve humidity, concentra on of the test agents. In the test chamber, the mixture passes through the filter un l the test agent is detected in the air sample at the outlet of the filter (breakthrough concentra on) or un l the filter protec on me, which is set by the RPE manufacturer, expires. CONFIGURATION: Test different types of filters on the same test equipment. Configura on op ons for one test equipment design. 1) Dynamics G: up 2 to 7*...
Open the catalog to page 2DATA SHEET (DYNAMICS G) DATA SHEET (DYNAMICS G2) SPECIFICATIONS VALUE UNIT SPECIFICATIONS VALUE UNIT The constant flow rate of the gas-vapor -air mixture through the tested product Relative humidity of gas-vapor-air mixture Temperature of gas-vapor-air mixture The direction of the flow of gas-vapor-air mixture through the tested product The volume concentration of the test agents in the gas-air-vapor mixture*: • Chlorine (Cl2) • Sulfur dioxide (SO2) • Ammonia (NH3) • Dimethyl ether (C2H6O) • Isobutane (C4H10) • Hydrogen sulfide (H2S) • Nitric oxide (NO) Overall dimensions...
Open the catalog to page 3cyclohexane hydrogen cyanide C3H4O acrolein C6H6 benzene *the number of test agents in one test equipment is determined individually PRINCIPLE OF OPERATION: control & test substance humidified air preparation unit dehumidified air evaporation unit DATA SHEET (DYNAMICS V) SPECIFICATIONS VALUE UNIT Constant flow rate of vapor-air mixture through the tested product Relative humidity of vapor-air mixture Temperature of vapor-air mixture The volume concentration of the test substance in the vapor -air mixture: • cyclohexane (C6H12) • hydrogen cyanide (HCN) • acrolein (C3H4O) • benzene (C6H6) The...
Open the catalog to page 4control & test substance air preparation unit tested & absorber filters vapor-air mixture The complete set of delivery is given in the instruction manual RELEVANT STANDARDS* for Dynamics G, G2, V, Hg: EN 1827, EN 12941, EN 12942, EN 14387, EN 405 *meets one or more standards. If you require testing to a standard not listed, please contact us.
Open the catalog to page 5Automatic control of test parameters,- fixation and formation of a test database with results Feedback of test results in real-time Control: touch display on test equipment, app on personal computer To export test results to your devices in PDF&EXCEL-file and print its Tests Test Log Standarts To create DATABASE of relevant standards, test modes, types and models of RPE, manufactures of RPE Interface lanai iaaPQ-_ WHY TEST EQUIPMENT DYNAMICS? SERVICE 1. Universal platform for research & quality control of RPE The software and technical capabilities of the «Dynamics» test equipment are...