Breathing resistance Test device Boreas
4Pages

{{requestButtons}}

Catalog excerpts

Breathing resistance Test device Boreas - 1

Measuring people’s safety determining breathing resistance Test device BOREAS convenient performance for a wide range of possibilities APPLICATIONS & INDUSTRIES ● RPE with filtering half-mask ● An -aerosol RPE with an insula ng front part ● An -gas filtering RPE with an insula ng front part ● Gas and an -aerosol (combined) filtering RPE with an insula ng front part ● Filtering self-rescuer ● RPE (including filtering) from radioac ve substances ● Industrial & fire safety, emergency protec on ● RPE cer fica on, research and design For developers and manufacturers of respiratory protective equipment (RPE) For certification bodies and testing laboratories

Open the catalog to page 1
Breathing resistance Test device Boreas - 2

DESCRIPTION Test device "Boreas" creates a constant air flow through the RPE in the directions of "exhalation" and "inhalation" and measures the air pressure difference between the surrounding atmosphere and the mask space of the RPE, calculates the resistance to air flow. device for inflating a dummy head SPECIFICATIONS VALUE UNIT Measurement range of volumetric air flow through the tested RPE: - in the direction of inhale - in the direction of exhale Measured resistance to constant airflow Overall dimensions (Width x depth x height) Power supply Power consumption Weight Time to enter the...

Open the catalog to page 2
Breathing resistance Test device Boreas - 3

Possibility to customize the air flow RESISTANCE ACTUAL FLOW PRESET FLOW0.0 mbar -0.1 l/min 0.0 l/min Name The complete set of delivery is given in the instruction manual DELIVERY COMPONENTS with test device RELEVANT STANDARDS*: EN 136, EN 140, EN 143, EN 149, EN 405, EN 1827 *meets one or more standards. If you require testing to a standard not listed, please contact us.

Open the catalog to page 3
Breathing resistance Test device Boreas - 4

1. Universal platform for research & quality control of RPE Test device «Boreas» has no restrictions in modes and can create an air flow with any value of volume flow within: • from 30 to 160 dm3 / min in the «exhalation» mode; • from 30 to 125 dm3 / min in the «inspiration» mode. For your convenience, the device contains ready-made modes according to the standards: 90 and 160 dm3/min. 2. Ergonomic design and mobility Test device «Boreas» is made of an inflatable head dummy with a silicone soft-touch coating and creates an ideal obturation with any face pieces . The device can even be...

Open the catalog to page 4

All Second Breath OÜ catalogs and technical brochures