Catalog excerpts
Remote Management - SiteManager™ 1149 and 3349 Secure High-Availability Remote Access to Industrial Devices • The SiteManager™ itself and its monitored devices are all centrally managed and accessible from the GateManager server. • Built-in serial, USB and Ethernet access agents for most PLC, HMI and Servo vendors in the market, as well as agent templates for video, voice, PC and Scada systems (including optional support for Siemens PPI and MPI) • Built-in Setup Assistant for intuitive first time network setup. • Automatic discovery of Ethernet and USB devices for easy single click configuration • All configuration, firmware and feature upgrades are done remotely through an intuitive web GUI accessible locally or via the GateManager. • Firewall friendly communication,- uses standard web protocols, and only inside-out. SiteManager™ is an off-the-shelf component in the Secomea Industrial Communications Solution program that in combination with Secomea’s GateManager™ and LinkManager™ ensures unified, uninterrupted and secure access to remote devices. SiteManager™ is security certified according to the highest industry standards of the industry, performed by the independent security organisation ProtectEM GmbH in Germany in close cooperation with the Deggendorf Institute of Technology. The SiteManager™ 1149 and 3349 are robust DIN mountable appliances that installs in the machine control panel, and provides remote access for on-demand servicing and programming of equipment, concurrently with static connections for monitoring and logging. The SiteManager™ 1149 and 3349 provide remote access to all types of industrial equipment via Ethernet,- Serial- or USB, using the equipment’s native protocols (e.g. Modbus, PROFINET, EtherCAT; EtherNet/IP etc.). The SiteManager™ 1149 and 3349 establish access to the Internet through the firewall of the existing wired network infrastructure, or wirelessly by the integrated WiFi option. Additionally the SiteManager supports Secomea LogTunnel in both Client and Master mode. LogTunnel allows you by drag’n’drop to establish a complete static infrastructure for linking a central SCADA system to remote devices independent of IP subnets, firewalls etc. • No requirement for public or fixed IP address. SiteManager is by default DHCP enabled. No need to re-configure the PLC with gateway address etc. • Can operate as carrier of alarms, email alerts etc. between devices and central logging servers over the Internet. • Built-in firewall, AES and x.509 certificatesfor and security certified in accordance with leading standards methodologies specified by NIST, ISA/IEC, BSI and ISECOM. • User-configurable email alerts for status monitoring and configurable I/O ports for custom alarms. • 4G/3G/GPRS internet access via external USB adapter. • WiFi support via Integrated module or via external USB adapter, configurable for either Client mode (Internet access) or AP mode (devices access) • Automatic failover between Ethernet, WiFi and Broadband for uninterrupted internet access. • Includes Secomea EasyTunnel Client support for allowing easy enrollment in a standard VPN network. • LogTunnel support allowing static tunnel connetions to a central SCADA system, which operates concurrently with other services such as on-demand access and VPN. • Unique built-in trouble shooting functionality for automatic disc
Open the catalog to page 1Remote Management - SiteManager™ 1149 and 3349 Unique Specifications Local Access Management and logging The SiteManager allows local administered access management via its Web GUI or digital ports, in addition to the central user access management. On top of this, all user connections made to the SiteManager and its connected devices are logged centrally on the GateManager. Drivers for any type device PLC GateManager™ Enabled GateManager™ enabled for easy, centralized configuration, backup, monitoring and access for remote service and maintenance of Secomea SiteManager and industrial...
Open the catalog to page 2Remote Management - SiteManager™ 1149 and 3349 Electrical Characteristics • 536 Mhz ARM Cortex A5 CPU • Input 12 - 24 V/DC, via screw terminals • Network Interfaces: 2 x 10/100 Mbit Ethernet (UPLINK, DEV1,) - RJ45 connection • 2 x USB 2.0 full speed (Host) • 1 x RS232 DB9 Serial port with full flow control • Power consumption: max 3W excl. any optional USB device.s (Calculate with a total of 8W incl. USB devices) • 2 x digital input ports • 1 x output relay (max 0,5A), 1 x digital output open drain (max 0,2A) • Integrated 2.4GHz WiFi module for Client mode, IEEE 802.11 b/g/n (AP...
Open the catalog to page 3All Secomea catalogs and technical brochures
-
SITEMANAGER 11xx/33xx SERIES
2 Pages
-
Data Collection Cloud (SDCC)
1 Pages
-
TrustGate SoftClient
3 Pages
-
SiteManager™ 1429 and 3429
3 Pages
-
TrustGate264
3 Pages
-
TrustGate164
3 Pages
-
TrustGate_60
3 Pages
-
TrustGate_62
3 Pages
-
SiteManager_1029-3229
3 Pages
-
1039-3239
3 Pages
-
1029-3229
3 Pages