Introduction
The VM12 amplifier is designed for measuring DC voltages in power distribution systems, specifically for public transport networks. It provides high voltage isolation to ensure safety for both equipment and personnel.
Specifications
  • Two standard models available: 0.9 kV (SG829062P00001) and 1.8 kV (SG829062P00002).
  • Supply voltage: 24 VDC ± 20%.
  • Input voltage: 0.9, 1.8 kV bipolar with fixed setting.
  • Output voltage: Us nom ± 5 V.
  • Error on gain and non-linearity: Less than ± 0.3%.
  • Cut off frequency (-3 dB): > 5 kHz.
  • Voltage consumption: < 5 VA.
  • Residual ripple: < 10 mVeff.
Features
  • Low non-linearity error.
  • Very high immunity.
  • High galvanic isolation.
  • Compact solution.
Technical Data
  • Galvanic isolation: EN50124-1, 3-port isolation between input, output, and power supply.
  • Operating temperature: -25 to +85 °C.
  • Galvanic isolation, input against output: 10 kVAC 50 Hz 1 min.
  • EMC standards: EN50121-5 (when mounted in a cubicle), EN61326 class B (standard for isolators).
Mechanical Data
  • Dimensions: 90 x 45 x 118 mm (H, W, D).
  • Weight: ~ 500 gr.
  • Sealing: IP 40 (Housing).
  • Mounting: DIN rail.
Application
The VM12 amplifier is suitable for use in environments requiring high voltage isolation and precise DC voltage measurement, particularly in public transport power distribution systems.
See more

Catalog excerpts

VM12-1

Voltage measurement

 Open the catalog to page 1
VM12-2

Application The VM12 amplifier is suitable for measuring DC voltages in power distribution systems for public transport networks. The VM12 measuring equipment, with its high voltage isolation, ensures safety for the equipment and for the personnel. Main features • • • • Low non-linearity error Very high immunity High galvanic isolation Compact solution Technical data Supply voltage Input voltage 0.9, 1.8 kV bipolar with fixed setting Output voltage Error on gain and non-linearity Less than ± 0.3 % < 100 ppm/K full scale Voltage consumption Residual ripple 3-port isolation between input, output...

 Open the catalog to page 2

All Secheron catalogs and technical brochures

  1. SPL

    8  Pages

  2. BMS15.18

    8  Pages

  3. BMS15.002

    3  Pages

  4. IS

    8  Pages

  5. BW

    10  Pages

  6. BTE03.04

    8  Pages

  7. MMC

    2  Pages

  8. MBS

    8  Pages

  9. SEPCOS

    8  Pages

  10. MIU10

    2  Pages

  11. VM10

    2  Pages

  12. VLD

    4  Pages

  13. Inverter

    4  Pages

  14. HPB45, HPB60

    8  Pages

  15. UR15-44

    4  Pages

  16. GB - G

    9  Pages

  17. IS series

    8  Pages

  18. SW series

    12  Pages

  19. BTE 03.04

    8  Pages

  20. XMS 40.08

    4  Pages

  21. BSV

    4  Pages

  22. RS series

    8  Pages

  23. HSb

    4  Pages

  24. BMS 08_08

    8  Pages

  25. UR6-31

    12  Pages

  26. AC MODBOX®

    2  Pages

  27. BVAC

    4  Pages

  28. MACS

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.