Product catalog summary
General Information: This document covers high-speed DC circuit-breakers (UR6, UR10, UR15) for rolling stock applications, protecting electric traction and auxiliary circuits in metro, EMU, and LRV vehicles from short-circuits and overloads. They also facilitate circuit connection or isolation from the vehicle's power supply.
Main Features: The circuit-breakers have a rated thermal current of 1000 A for UR6/10 and 1500 A for UR15, with operational voltages of 900 VDC and 1800 VDC. They feature high insulation levels, low maintenance, and a compact design, complying with IEC60077-1/3 and IEC 61373 standards.
Breaking Current Parameters: Detailed specifications include rated operational voltage, insulation voltage, overload capacity, and short-circuit making and breaking capacity, with specific time constants for different arc chute types.
Low Voltage Auxiliary Circuit: The control circuit operates at nominal voltages from 24 to 110 VDC, with defined power consumption and mechanical operation times. Auxiliary contacts are potential-free, with various configurations.
Operating Conditions: Designed for indoor installation below 1400 meters altitude, with ambient temperatures from -25°C to +70°C, a pollution degree of PD3, and mechanical durability up to 500,000 operations.
Product Selection: Selection requires information on application load cycle, maximum ambient temperature, and high voltage connection type, emphasizing adherence to recommended current densities.
Integration and Installation: Details on dimensions, weights, insulation distances, protective enclosures, and cable gland configurations are provided for product integration.
Control Schemes: Low voltage control schemes for electric and magnetic holding are outlined, including typical values for closing coils and power consumption.
Designation Code for Ordering: Use the latest brochure from www.secheron.com for the 20-digit type designation code. Include setting value IDs in the order form, noting that some variants may not be combinable. The bold part of the code defines the device type, while the complete code identifies the product.
Product Specifications: Options include breaker type (UR), conventional thermal current (1000 A or 1500 A), rated operational voltage (900 V or 1800 V), mounting position, protective enclosure, type of low voltage connector, high voltage cable gland plate, number and position of cable glands, external diameter of HV cables, nominal control voltage, varistor on coil, holding type, range of direct over-current instantaneous release, and auxiliary contacts.
Additional Notes: Low voltage connectors must be ordered separately, and the setting value for direct over-current release must be specified.
See more

Catalog excerpts

UR6-31-1

COMPONENTS High-speed DC circuit-breakers for Rolling Stock Type UR6, UR10 and UR15

 Open the catalog to page 1
UR6-31-2

General information UR6, UR10 and UR15 are DC high-speed current limiting circuit-breakers with natural cooling, trip free, single pole, bi-directional, with electromagnetic blow-out, electric control circuits and direct over-current instantaneous release. Of open type construction, the UR6, UR10 and UR15 can also be delivered with protective enclosure IP55 for roof or under-frame mounting on traction vehicles. These circuit-breakers are primarily designed to protect main and auxiliary circuits of DC traction vehicles against shortcircuits and overload currents, as well as to connect or isolate...

 Open the catalog to page 2
UR6-31-3

Data for product selection MAIN HIGH VOLTAGE CIRCUIT Maximum operational voltage Rated insulation voltage Rated operational current Conventional free air thermal current <1' Operational category Over-voltage category Rated short-circuit making and breaking capacity / Time constant Direct over-current instantaneous release <4' Power frequency withstand voltage U5 - Between opened main contact [kV] 8 8 8 - Between closed main contact and earth & control circuit [kV] 10 10 10 - Between low voltage circuits and earth [kV] 2 2 2 Rated impulse withstand voltage Uimp [kVDC] 18 18 18 Maximum peak arc...

 Open the catalog to page 3
UR6-31-5

Information for product integration Main dimensions The DIN-ISO 2768-1 coarse tolerances are applied to these dimensions. All dimensions are in mm. The maximum allowed atness deviation of the support frame is 0.5 mm. (1) Space needed for the removal of the arc chute (2) Space needed for the removal of the auxiliary housing Insulation distances Minimum insulation distances [mm] UR6 To insulating wall UR10 UR15 90 90 90 55 55 55 C* 0 0 0 A 350 350 350 B 200 200 200 C* To earth A B 150 150 150 Weights Weights (1) [Kg] UR6 UR15 Arc chute 900V 5 UR10 27 28 29 Arc chute 1800V 37 38 39 (1) Weights for...

 Open the catalog to page 5
UR6-31-6

Low voltage control scheme Electric holding: E type Magnetic holding: M type A B Ie C D E A S V= S V= + D C 100% + 100% B Ie F E 0 0,5 R1 G t [s] ~ 5% 1 Customer scope A B C D E Rp Rs 0 – F t [s] 0 ~ 20% 0,5 Sécheron scope 1 tc tc+0.5 tc+1 – Customer scope Start of the closing pulse: the contacts F + G close. Closing pulse: 0.5 to 1 s. Start of the holding current: the contact G opens. Holding: a R1 resistance limits the holding current to 5% of the closing current. Opening: the contact F opens to provoke the interruption of the holding current. A B C D Sécheron scope Start of the closing pulse:...

 Open the catalog to page 6
UR6-31-7

Low voltage interface Without protective enclosure Conguration with 2 auxiliary switches Conguration with 6 auxiliary switches Direct connection on auxiliary switches and closing coil. Low voltage cables goes through the glands of the auxiliary contacts housing. With protective enclosure Connector Harting type HAN: Note!: Low voltage connectors are delivered with all pins mounted. Harting type HAN 18 (Standard for 2a + 2b auxiliary switches) Harting type HAN 28 (Standard for 6a + 6b auxiliary switches) Connector type VEAM: Note!: Low voltage connectors are delivered with all pins mounted. VEAM...

 Open the catalog to page 7
UR6-31-8

Low voltage wiring diagrams Legend of the schemes Circuit-breaker main contact Varistor on coil Circuit-breaker closing coil a b 1a+1b - Switch PF Direct connection (Conguration without protective enclosure) Auxiliary contacts - 2a + 2b conguration V (1) 3 1 3 1 B U Auxiliary contacts- 6a + 6b conguration (1) 3 1 3 1 3 1 3 1 A 4 2 3 1 B C D E F 4 2 4 2 4 2 4 2 4 2 4 2 E 4 2 V (1) U (1) 1 3 (1) Double cable only for 24VDC control voltage Harting type HAN connector (Standard for protective enclosure) Only the pins related to your selected conguration page 12 will be wired according to the below’s...

 Open the catalog to page 8
UR6-31-9

Options (subject to additional costs) Protective enclosures The TDP/TDS enclosures for UR6-31/UR10-41/UR15-41 or UR6-32/UR10-42/UR15-42 can be directly mounted on the vehicle’s roof or under the vehicle’s frame. UR6-31/UR10-41/UR15-41 UR6-31/UR10-41/UR15-41TDS/TDP UR6-31/UR10-41/UR15-41 Weight with breaker: 46/48 kg ( IP55) TDP TDS Example of TDP box xing on the vehicle’s roof 36 5 8± 15 30 35 5 5 69 373 LV Note!: Color for URxx.31/41 enclosure is black. UR6-32/UR10-42/UR15-42 UR6-32/ UR10-42/UR15-42 TDS/TDP UR6-32/UR10-42/UR15-42 Weight with breaker: 60 / 62 kg ( IP55) TDS Example of TDS box...

 Open the catalog to page 9
UR6-31-10

Cable glands type selection Cable glands standard configuration The high voltage cable gland plate will be delivered assembled according to the diagram shown below. The customer himself, can easily change the position of these glands and protection caps according to his own needs.

 Open the catalog to page 10
UR6-31-11

Designation code for separately ordered mobile connector (for optional protective enclosure) Mobile connector Auxiliary switches Device Number Type Fixed connector type Number of pin Size 2.5 mm² Cable gland Size 1.5 mm² Sécheron’s number Overall width: XX [mm] (1) Connector SG102955R00001 SG102955R00003 Harting HAN 18 4 431 SG100025R00007 (for 24VDC) 14 460 SG102955R00004 PF 431 SG102955R00002 2a+2b 460 430 M32 UR6 UR10 UR15 6a+6b PF Harting HAN 28 4 24 4 2a+2b PF M32 8 VEAM type 13 pins PG29 2 10 SG100025R00008 (for 36-110VDC) 430 30 0 SG100025R4 (for 24VDC) 430 SG100025R1 (for 36-110VDC) 430...

 Open the catalog to page 11

All Secheron catalogs and technical brochures

  1. SPL

    8  Pages

  2. BMS15.18

    8  Pages

  3. BMS15.002

    3  Pages

  4. IS

    8  Pages

  5. BW

    10  Pages

  6. BTE03.04

    8  Pages

  7. MMC

    2  Pages

  8. MBS

    8  Pages

  9. SEPCOS

    8  Pages

  10. MIU10

    2  Pages

  11. VM12

    2  Pages

  12. VM10

    2  Pages

  13. VLD

    4  Pages

  14. Inverter

    4  Pages

  15. HPB45, HPB60

    8  Pages

  16. UR15-44

    4  Pages

  17. GB - G

    9  Pages

  18. IS series

    8  Pages

  19. SW series

    12  Pages

  20. BTE 03.04

    8  Pages

  21. XMS 40.08

    4  Pages

  22. BSV

    4  Pages

  23. RS series

    8  Pages

  24. HSb

    4  Pages

  25. BMS 08_08

    8  Pages

  26. AC MODBOX®

    2  Pages

  27. BVAC

    4  Pages

  28. MACS

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.