D.C. Switchgear Range Type MBS ( IEEE / ANSI standards )
Open the catalog to page 1D.C. SWITCHGEAR RANGE / TYPE MBS ( IEEE / ANSI STANDARDS ) A domain of expertise With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world leader and major partner for electrification of DC traction networks. Covering all activities from calculation, network design and engineering, up to the production of the DC Systems, Sécheron SA can offer customers and partners tailor made solutions based on a modular concept and standard products. Our equipment is developed on world leading technology and proven worldwide design and acceptance. In-house...
Open the catalog to page 2HSCB D.C. Switchgear: Characteristics Symbol Cubicle type Rated service current Rated voltage Circuit breaker type Power frequency withstand voltage Active part to earth (50 Hz, 1min) Main busbar Rated short-circuit current (800V) Protection degree (general/roof) Ambient temperature range *IP42: option. For further characteristic: refer to the data sheet for the individual circuit-breaker type. HSCB D.C. Switchgear: Composition Unique feature: Key components of the switchgear are designed and manufactured by Sécheron and are fully compatible. Protection and Control Unit: SEPCOS Touch Screen Interface:...
Open the catalog to page 3D.C. SWITCHGEAR RANGE / TYPE MBS ( IEEE / ANSI STANDARDS ) Safety features / functioning The withdrawable high speed circuit breaker trolley has four positions: • Service position • Test position • Disconnected position • Removed position When the trolley is in service position, the front high voltage door is locked and it is not possible to access the trolley. When high voltage is applied to the breaker, it must be open before the trolley can be moved from service to test position. The trolley is moved from one position to another either manually by an external handle or electrically via the...
Open the catalog to page 4Disconnecting D.C. Switchgear: Description Disconnector cubicles are applied for incoming DS, negative DS or coupling DS. The system contains two compartments: • High voltage compartment • Low-voltage compartment Each compartment has a separate front door and can be mounted against the wall. Cable connection is possible from the bottom or top. Disconnectors are rated 2000A, 4000A, 6300A and 8000A. Incoming DS Cubicle: Incoming DS cubicles isolate the positive high voltage output transformer/rectifier group from the feeder DC distribution bus. Disconnectors may have single or double poles. Double...
Open the catalog to page 5D.C. SWITCHGEAR RANGE / TYPE MBS ( IEEE / ANSI STANDARDS ) Protection Relay SEPCOS is a protection and control unit that is applied to the outgoing feeder or the incoming HSCB cubicles in the DC traction substation. Main features: • Modular PLC concept, PLC programming, IEC61131 normalized programming. • Fully approved in railway substation environment IEC60255-22. • High noise immunity thanks to sampling rate at 40 microseconds and 16 bits A-D converter. Protection functions: • All typical protection functions (e.g. Function DDL +/-, Imax +/-, etc.). Control functions: • HSCB ON / OFF control...
Open the catalog to page 6MBS line up Complete DC switchgear can be provided in line with MBS cubicles as shown below. HSCB Cubicles: Applications 1. Line feeder MAIN BUSBAR MAIN BUSBAR MAIN BUSBAR 2. Line feeder with earthing switch 5. Line feeder with Line Test 3. Line feeder with Line Test Line Test isolating switch 6. Line feeder with bypass and isolating switch MAIN BUSBAR BY-PASS BUSBAR BY-PASS BUSBAR Line Test MAIN BUSBAR Line Test MAIN BUSBAR Installation of lightning arrester for outgoing feeder is available upon request. 7
Open the catalog to page 7Standards According to standards: • IEC61992-2:2006, EN50123-2:2003, IEC60980 (Seismic tests), C37.14-2002, C37.16-2009, C37.20.1-2002. Approved type test reports available. Rated continuous current test reports 8 kA Rated maximum voltage Rated continuous current Rated peak current Rated-short-circuit current Main features Short-circuit current withstand test Short-time withstand current Rated maximum voltage Rated continuous current Rated peak current Rated short-time current Rated-short-circuit current Rated control voltage Degree of protection Main features Main features Short-time withstand...
Open the catalog to page 88 Pages
12 Pages
8 Pages
3 Pages
8 Pages
10 Pages
4 Pages
8 Pages
2 Pages
9 Pages
4 Pages
8 Pages
8 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
9 Pages
8 Pages
8 Pages
12 Pages
8 Pages
4 Pages
4 Pages
8 Pages
4 Pages
8 Pages
12 Pages
2 Pages
4 Pages
8 Pages