video corpo

MACS

MACS

MACS

Product catalog summary
Overview: The Multi-functional Main AC Switch (MACS) is designed for rolling stock operating on 15 kV and/or 25 kVAC networks. It is a compact and lightweight solution that integrates various high voltage functions, making it suitable for both indoor and outdoor installations.
Specifications:
  • Operational Voltage: 15 kV or 25 kV
  • Thermal Current: 1000 A
  • Impulse Withstand Voltage: 125 kV or 170 kV
  • Mechanical and Electrical Endurance: Over 200,000 operations
  • Operating Temperature: -40°C to +70°C (optional -50°C to +70°C)
  • Standards: IEC60077-1/-2/-4, IEC61373, EN50121-3-2, NF F16-101/-102
Features:
  • Automatic opening via spring release for safety
  • Vertical or horizontal mounting options
  • Optional integrated Earthing Switch and Surge Arrester
  • Ice breaking capability up to 20 mm
Applications: The MACS is used for switching and protection of main and auxiliary electric circuits in locomotives, trains, and EMUs.
Technical Data:
  • Rated Operational Frequency: 16.7 Hz, 50/60 Hz
  • Peak Short-Circuit Making Current: 63 kA for 15 kV, 50 kA for 25 kV
  • Control Circuit Voltage: 24 to 110 VDC
  • Mechanical Opening Time: ≤ 50 ms
Installation and Options:
  • Can be mounted on the roof or underframe
  • Available in manual or electric versions
  • Surge Arrester options for enhanced protection
Conclusion: The MACS offers a versatile and reliable solution for high voltage switching and protection in railway applications, with customizable options to meet specific operational needs.
See more

Catalog excerpts

MACS-1

COMPONENTS Multi-functional Main AC Switch for rolling stock Type MACS

 Open the catalog to page 1
MACS-2

With the MACS, Sécheron offers a new generation of AC vacuum circuit-breaker to the manufacturers and operators of vehicles running on AC networks. This product completes the BVAC’s range that has been marketed by Sécheron since 1991. All the field experience gathered since then on thousands of BVAC in operation worldwide, has been integrated to provide the MACS with the maximum added value for car builders and operators. The MACS is a multi-functional switch that is proposed in three main variants: the AC circuit-breaker (AC VCB) remains the core of the product, to which an Earthing Switch (ES)...

 Open the catalog to page 2
MACS-3

Technical data Symbol Unit 15 kV 25 kV [VAC] [VAC] [A] [A] [Hz] 17’250 (1) 27’500 (1) 1000 1000 16.7 C3 63 25/50 63/25/1 75 125 27’500 (1) 27’ 500 (1) 1000 1000 50, 60 C3 50 20/50 63/25/1 75 125 / 170 MAIN HIGH VOLTAGE CIRCUIT AC Circuit-Breaker Rated operational voltage Ue Rated insulation voltage Ui Rated operational current Ie Conventional free air thermal current (2) Ith Rated operational frequency f Operational category Peak short-circuit making current IMC Rated short-circuit breaking current / % value of the DC component Peak and rated short-time withstand current Îcw/Icw/t Rated power-frequency...

 Open the catalog to page 3
MACS-4

Main dimensions The DIN-ISO 2768-1 coarse tolerances are applied to these dimensions. All dimensions are in mm. The maximum allowed flatness deviation of the support frame is 1 mm. Weight: Refer to the table HV and earth connections: M12 screws. Uimp (kV) HV 241 125 A (mm) 563 B (mm) 280 Weight (kg) 95±2 15 B A HV 170 578 295 96±2 150* 200* 140 Installation frame level 150* 420 420 64 32 880 114 101 420 22.5 385 >430 330 Roof opening and frame dimensions 105 150 388 385 430 420 65 110 406 6 x M12 320 >940 940 *: Space needed to remove the cover and to operate the optional Earthing Switch. Options...

 Open the catalog to page 4
MACS-5

AC Circuit-Breaker and Earthing Switch (Uimp = 170 kV) Weight: AC Circuit-Breaker + 14 kg (manual version) AC Circuit-Breaker + 22 kg (electric version) Electric version (option) Manual version (standard) HV 142 50* 150* 870 220* 140 140 546 HV 303 320* 61 47 AC Circuit-Breaker and Surge Arrester Surge Arrester connections: M12 screws. Weight: Refer to the table page 6 for the additional weight of Surge Arrester. H: refer to page 6 for the Surge Arrester height. 15 H HV The connection between the AC Circuit-Breaker and the Surge Arrester is not represented on the drawing but is available in the...

 Open the catalog to page 5
MACS-6

AC Circuit-Breaker and Surge Arrester Secheron recommends for a safe and efficient protection against lightning and switching overvoltages to use two Surge Arresters, SA1 and SA2, in the high voltage circuit of the vehicle. Should the customer want to integrate one Surge Arrester to the MACS, the appropriate type corresponding to application and service conditions can be found in the following table. • Metal oxide Surge Arrester without spark gaps, designed for rolling stock applications and outdoor mounting • High current impulse ln = 4/10 us : 100 kApeak • Maximum ambient temperature: +40°C...

 Open the catalog to page 6
MACS-7

Definition of the auxiliary switches Potential free contact Type: PF a The contact “a” corresponds to a NO (Normally Open) contact. The contact “b” corresponds to a NC (Normally Close) contact. b Designation code for separately ordered items LV mobile connector for AC Circuit-Breaker MACS configurations Auxiliary switches Device (1) Number Type (2) Fixed connector type Type Mobile connectors Number of pin Cable Cable Size Size gland entry 2.5 mm² 1.5 mm² Secheron's number Case 1 AC VCB Case 2 AC Circuit-Breaker without Earthing Switch AC VCB 4a + 4b 8a + 8b PF PF SG325249R00101 Harting HAN 51...

 Open the catalog to page 7

All Secheron catalogs and technical brochures

  1. SPL

    8  Pages

  2. BMS15.18

    8  Pages

  3. BMS15.002

    3  Pages

  4. IS

    8  Pages

  5. BW

    10  Pages

  6. BTE03.04

    8  Pages

  7. MMC

    2  Pages

  8. MBS

    8  Pages

  9. SEPCOS

    8  Pages

  10. MIU10

    2  Pages

  11. VM12

    2  Pages

  12. VM10

    2  Pages

  13. VLD

    4  Pages

  14. Inverter

    4  Pages

  15. HPB45, HPB60

    8  Pages

  16. UR15-44

    4  Pages

  17. GB - G

    9  Pages

  18. IS series

    8  Pages

  19. SW series

    12  Pages

  20. BTE 03.04

    8  Pages

  21. XMS 40.08

    4  Pages

  22. BSV

    4  Pages

  23. RS series

    8  Pages

  24. HSb

    4  Pages

  25. BMS 08_08

    8  Pages

  26. UR6-31

    12  Pages

  27. AC MODBOX®

    2  Pages

  28. BVAC

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.