ELECTRICAL SAFETY SOLUTIONS / CONTACTOR RANGE Type SEC RAIL VEHICLES / FIXED INSTALLATION
Open the catalog to page 1GENERAL INFORMATION The SEC contactor is a high duty class component, ~ designed to withstand the most severe applications in terms of environment and required performances ~ for rail mobility or fixed installations. Combining high electrical and mechanical endurances, efficient low current bi-directional blow-out device, and a smart 3 M control unit making the SEC operation independent 3~ from both ambient temperature and control voltage, the SEC is a 3 unique contactor to be used almost regardless of theM service conditions. 3~ APPLICATIONS, TYPICAL EXAMPLES DC rail vehicle Power line Current...
Open the catalog to page 2MAIN MAIN BENEFITS BENEFITS Operational frequency category C3 for 1,000 A and C2 for 1,300 A with a minimum mechanical durability of 2,000,000 operations Efficient blow-out circuit for low current interruptions Reduced power consumption thanks to a coil controller that controls the closing and opening operations Closing and opening performances independant from both control voltage level and ambient temperature Horizontal or vertical mounting Double pair of main contacts allowing a longer life time Low maintenance requirements and easy access to the main contacts for replacement. All arc chutes...
Open the catalog to page 3DATA FOR PRODUCT SELECTION Symbol MAIN HIGH VOLTAGE CIRCUIT Component category Type of main contact Normally Open Rated operational voltage Rated short-time withstand current Peak short-time withstand current Maximum making capacity Rated insulation voltage Conventional free air thermal current (1) Rated operational current/operational frequency - DC voltage or AC voltage (16.7, 25 & 50/60 Hz) Horizontal/Vertical mounting Maximum breaking capacity Rated power-frequency withstand voltage (50 Hz/1min) - Between main contacts (open) - Main circuit (closed) to earth Breaking overvoltage At Tamb =...
Open the catalog to page 4MAIN DIMENSIONS HV connections Earth connections Dimensions without tolerances are indicative. All dimensions are in mm. The maximum allowed flatness deviation of the support frame is 0.5 mm. M12 screws M3 screws terminal block or AMP connector (option) Fixing points /// HIGH VOLTAGE LATERAL CONNECTIONS PRODUCT INTEGRATION INSULATION DISTANCES AND WEIGHTS B SEC contactors have been homologated according to IEC60077-2 with the following insulation distances. Clearance against insulating wall. Clearance against earth. F or breaking current ≤ 2kA (≤ 1kA for SEC40.10 and SEC36.13). For higher breaking...
Open the catalog to page 5LOW VOLTAGE CONTROL DIAGRAM /// LOW VOLTAGE CONTROL MODE The two control modes that can be used to control the SEC are represented hereunder: - Indirect mode - Direct mode Required data for k0 and k1 control relays : Nominal supply voltage Un [VDC] Nominal control voltage UEF [VDC] Required data (1) K0 relays Required data (1) K1 relays INDIRECT MODE NON ISOLATED CONTROL INPUT Sécheron’s scope Customer’s scope C ontrol voltage (UEF) can be different from supply voltage (Un). Notes: Isolated or non isolated control mode is to be determined when0 k ordering. Please + refer to codification page...
Open the catalog to page 6DIRECT MODE NON ISOLATED CONTROL INPUT Screws terminal block AMP connector Screws terminal block AMP connector Coil controller main contact Brochure Brochure Brochure 6 7 Légende: /// WIRING DIAGRAM WITH 2a + 2b AUXILIARY SWITCHES Notes: Difference between configuration 1 & 2 relates to the switching offset time between auxiliary switches. ELECTRICAL SAFETY SOLUTIONS, CONTACTOR RANGE, RAIL VEHICLES / FIXED INSTALLATION, TYPE SEC
Open the catalog to page 7/// WIRING DIAGRAM WITH 3a + 3b AUXILIARY SWITCHES Screws terminal block AMP connector OPTIONS (SUBJECT TO ADDITIONAL COSTS) b 41 Mobile connectors Type Secheron’s number The low voltagwe AMP mobile connector can be ordered separately. ELECTRICAL SAFETY SOLUTIONS, CONTACTOR RANGE, RAIL VEHICLES / FIXED INSTALLATION, TYPE S
Open the catalog to page 8HIGH VOLTAGE BOTTOM CONNECTIONS HV connections Earth connections M3 screws terminal block or AMP connector (option) Fixing points /// DIMENSIONS, INSULATION DISTANCES AND WEIGHTS Clearance against insulating wall. Clearance against earth. F or breaking current ≤ 2kA (≤ 1kA for SEC40.10 and SEC36.13). For higher breaking conditions please contact Sécheron. ELECTRICAL SAFETY SOLUTIONS, CONTACTOR RANGE, RAIL VEHICLES / FIXED INSTALLATION, TYPE SEC
Open the catalog to page 9SECHERON CONTACTORS RANGE U [V= / V~] (1) BMS09... can be used for rated voltages up to 2,000 VAC 1 pole Arc chute Type A 1 pole Arc chute Type A 2 poles Arc chute Type A 1 pole Arc chute Type A 1 pole Arc chute Type A ELECTRICAL SAFETY SOLUTIONS, CONTACTOR RANGE, RAIL VEHICLES / FIXED INSTALLATION, TYPE SEC 1 pole Arc chute Type A
Open the catalog to page 10BROCHURE REFERENCE FOR OTHER SÉCHERON’S CONTACTORS BMS..08/BMS..10 Type ROLLING STOCK ROLLING STOCK (Line/separation contactors, ...). (Line/separation contactors, ...). FIXED INSTALLATION (depot feeder contactor...). FIXED INSTALLATION (depot feeder contactor, ...). ROLLING STOCK (Line/separation contactors, ...). ROLLING STOCK (Line/separation contactors, PM motor,...). FIXED INSTALLATION (depot feeder contactor...). FIXED INSTALLATION (depot feeder contactor, ...). ROLLING STOCK (Pre-charging, Heating, HVAC, ...). ROLLING STOCK (Line/separation contactors, ...). FIXED INSTALLATION (Line testing,...
Open the catalog to page 11DESIGNATION CODE FOR ORDERING • Be sure to establish the designation code from the latest version of our brochure by downloading it from the website: www.secheron.com. • Be careful to write down the complete alphanumerical designation code with 12 characters when placing your order. • For technical reasons some variants and options indicated in the designation code might not be combined, therefore validate your configuration with Sécheron before ordering. • For other configurations not described in the brochure, please contact Sécheron. SEC 10 The bold characters of the designation code define...
Open the catalog to page 128 Pages
8 Pages
3 Pages
8 Pages
10 Pages
4 Pages
8 Pages
2 Pages
9 Pages
4 Pages
8 Pages
8 Pages
8 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
9 Pages
8 Pages
8 Pages
12 Pages
8 Pages
4 Pages
4 Pages
8 Pages
4 Pages
8 Pages
12 Pages
2 Pages
4 Pages
8 Pages