PV150+A fast and simple PV tester The PV150+ allows electrical safety and performance verification of modern photovoltaic installations. The PV150+ is an upgraded version of the popular PV150, designed to better support the testing of PV modules with recent technology advances and associated higher efficiencies. Combines ground continuity, DC operating power and operating current test functions. It can also test insulation resistance, open circuit voltage and short circuit current at the push of a button. Why buy the PV150+? > Improved capacitive induced in-rush protection by a factor of 300% > Combines PV commissioning tests required by IEC 62446. > Enables the user to safely test energized PV arrays > Easy to use, single key testing and measurement operation > On-board data storage and USB connectivity for data export Key Features: > Ground (earth) continuity measurement with test lead null for long test-leads > PV string open circuit voltage measurement up to 1000V DC with polarity indication > PV string short circuit current measurement up to 15A DC > PV array insulation test at 250/500/1000V > Tests individual PV modules or strings Together, we’re making our world a safer place. Every. Single. Day. T: +44 (0) 191 587 8741 E: sales@seaward.com
Open the catalog to page 1Open Circuit Voltage Measurement (PV Terminals) Display Range 0.0VDC - 1000VDC Enunciators DC voltage polarity correct or reversed Short Circuit Current Measurement (PV Terminals) Display Range 0.00ADC - 15.00ADC Earth Continuity Resistance Measurement (4mm Terminals) Insulation Resistance (Auto Test Sequence, PV Terminals and Test Voltage Open Circuit Test Voltage Specification Test Voltage @ 1mA Test Current Short Circuit Display Range Measuring Range (EN 61557-2) Resolution Accuracy Visible Warning Circuitry Protection Repeat tests as per IEC61557-4 What’s in the box? > PV150+ > 2x MC4...
Open the catalog to page 2Rpe Voltage Measurement (4mm Terminals) Display Range 30V - 440VAC/DC Voltage Measuring Range 30V - 440VDC Operating Current (via AC/DC Current Clamp) Display Range 0.1A - 40.0A Current Measuring Range 0.1A - 40.0A DC DC Operating Power (via AC/DC Current Clamp and PV Terminals) Display Range 0.00kW - 40kW General Specification Connectivity USB download to PC (CSV format) Wireless "Solarlink TM” to Survey 200R (range ~30m/100ft) Software compatibility Compatible with SolarCert software (English language only) Instrument Dimensions and Weight Weight Dimensions Display Power Source Battery...
Open the catalog to page 3All Seaward catalogs and technical brochures
-
Seaward NTB-1
2 Pages
-
D255
2 Pages
-
PrimeTest 100
2 Pages
-
Solar Survey 100/200R Series
4 Pages
-
PrimeTest 50
2 Pages
-
00 Series
2 Pages
-
2018 Seaward PAT Selector
15 Pages
-
Cropico DO4000 Series
2 Pages
-
Cropico DO4A
2 Pages
-
SDR Series
1 Pages
-
Printers and Scanners
8 Pages
-
PR11
2 Pages
-
MTS
2 Pages
-
HAL Series
5 Pages
-
HAL LED
4 Pages
-
CR Series
1 Pages
-
Apollo+ Series
6 Pages
-
Seaward Manufacturing
12 Pages
-
PATGuard 3 PAT Testing Software
153 Pages
-
PrimeTest 250+ PAT Tester
4 Pages
-
Apollo 600
5 Pages
-
PrimeTest 250+
4 Pages
-
Apollo 400
5 Pages
-
Powercheck 1557
2 Pages
-
Power Clamp
3 Pages
-
Apollo 500
20 Pages
-
Cropico RS3 Datasheet
2 Pages
-
Cropico RM6 Datasheet
1 Pages
-
Cropico RBC Datasheet
2 Pages
-
Cropico RBB Datasheet
2 Pages
-
Cropico CM5-N Datasheet
1 Pages
-
Cropico RM8 Datasheet
1 Pages
-
Cropico RM6N Datasheet
1 Pages
-
Cropico DO7010 Datasheet
2 Pages
-
Cropico DO7Plus Datasheet
2 Pages
-
Cropico DO6 Datasheet
2 Pages
-
Cropico DO7E Datasheet
2 Pages
-
Cropico DO7 Datasheet
2 Pages
-
PowerCheck 1557 Datasheet
2 Pages
-
PAT Checkbox Datasheet
2 Pages
Archived catalogs
-
Supernova Elite
2 Pages
-
Seaward Product
72 Pages
-
Powerplus 1557
4 Pages
-
PAT Testing Product
20 Pages
-
Cropico Product
48 Pages
-
ClareHAL
12 Pages
-
Clare Product
28 Pages
-
Calibrationhouse
2 Pages
-
Cropico DP6 Datasheet
2 Pages
-
Seaward PAT Testing Guide
20 Pages
-
Cropico DO5000-CS Datasheet
1 Pages
-
Cropico DO8000 Datasheet
2 Pages
-
Clare G2000 Datasheet
2 Pages
-
Clare B433R Datasheet
2 Pages
-
Clare Elite Datasheet
4 Pages
-
Clare B255 Datasheet
2 Pages
-
PrimeTest 300 Datasheet
2 Pages
-
SEN60204 Datasheet
22 Pages
-
SD 300 Datasheet
2 Pages
-
PrimeTest 250 Datasheet
2 Pages
-
Clare Horizon II Datasheet
2 Pages
-
Clare PowerSmart Datasheet
2 Pages
-
Clare A320 Datasheet
2 Pages
-
Clare Sentinel Datasheet
2 Pages
-
Clare HAL Combi Datasheet
2 Pages
-
Type L Plus Datasheet
2 Pages
-
PowerPlus 1557 Datasheet
2 Pages
-
Proving Units Datasheet
2 Pages
-
PowerGuard Pro Mobile 2
2 Pages
-
PowerGuard Pro 2 Datasheet
2 Pages
-
PATGuard Elite 2 Datasheet
2 Pages
-
Clare A252 Datasheet
1 Pages
-
Halo Hook Datasheet
2 Pages
-
IRT 1557 Datasheet
2 Pages
-
ERT 1557 Datasheet
2 Pages
-
VT800D Datasheet
2 Pages
-
VT800 Datasheet
2 Pages
-
PrimeTest 350 Datasheet
2 Pages
-
PATGuard Pro 2
2 Pages
-
PATGuard Lite 2
2 Pages
-
PATGuard Elements Datasheet
2 Pages
-
Test n Tag Datasheet
2 Pages
-
Supernova Plus Datasheet
2 Pages
-
PowerTest 1557 Datasheet
2 Pages
-
Guide to 17th Edition Testing
12 Pages
-
DM800/DM800R
1 Pages
-
Europa Plus PAT Tester
2 Pages
-
Supernova Plus PAT Tester
2 Pages