Group: Seaward Electronic Ltd.
Catalog excerpts
SOLAR www.seawardsolar.com Solar Power Clamp Power analysis tool for photovoltaic installations KEY FEATURES: High performance instrument for measuring AC and DC power Includes MC4 test leads for DC power measurements (others available) Power Factor measurement and harmonic analysis up to 25th harmonic for inverter performance analysis Rugged, robust and handheld, with active backlight and inbuilt cable illuminating torch – ideal for use in confined and/or dark spaces. The new Solar Power Clamp is a clamp meter capable of measuring AC and DC circuit power, in addition to true RMS voltage and current, resistance & continuity, diode check, capacitance, harmonic distortion and power factor. The Solar Power Clamp is especially designed for installers and technicians interested in power measurement and analysis on AC & DC systems and carrying out diagnostic checks. Full clamp-on multimeter capabilities KIT INCLUDES: Seaward Solar Power Clamp 2 x MC4 – 4mm test leads Test lead, red, with test probe Test lead, black, with test probe In order to ensure the maximum yield from a PV system it is important to check the efficiency of the conversion of DC power generated by the PV modules to AC power fed into the electrical installation. Efficiency is determined by measurement of both the voltage and current on the DC and AC sides of the inverter and using the measured values to calculate the DC and AC power. Alternatively, the DC or AC power can be measured directly on either side of the inverter in seconds using the Seaward Solar Power Clamp. The Power Clamp simply clips over the cable to measure current and the supplied in-line connectors can be used to measure the DC voltage whilst the PV modules are connected to the inverter, giving an accurate true RMS reading of the power whilst the system is operational. The Solar Power Clamp can be used when installing a PV system to ensure the inverter is operating correctly or for maintenance and troubleshooting on the PV system after commissioning. If a PV system isn’t generating the expected level of power under known Carrying case Quick start guide
Open the catalog to page 1SOLAR www.seawardsolar.com irradiance and temperature conditions, this may indicate a fault with one or more components in the system. Similarly, the presence of harmonics on the AC output of an inverter may indicate a fault within the inverter. In addition to power and efficiency measurements, the harmonic analysis function of the Solar Power Clamp can be used as a means of detecting faults within the inverter. As PV systems have a lifetime of over 25 years, periodic inspection and testing is necessary to ensure that they are operating efficiently. Most inverters have a lifetime much...
Open the catalog to page 2SOLAR www.seawardsolar.com ToTal harMoniC diSTorTion Function Range ACA /ACV 0.1 – 99.9% Resolution 0.1% Harmonic Order H01 ~ H12 H13 ~ H25 Resolution inruSh CurrenT Function ACA Power faCTor Range Resolution Basic Accuracy ALSO AVAILABLE: Accuracy ± (3.0% + 10dgt) Solar PV100 Installation Test Kit Solar Survey 100 and 200 irradiance meters SolarCert Elements Test Reporting & Certification Software Solar Certificate & Report Pads SolarTags reSiSTanCe, ConTinuiTy & diode Function Range Resistance 0.0Ω - 999.9Ω 1.000 kΩ -99.99 kΩ Continuity 0.0Ω - 999.9Ω Diode 0.40 ~ 0.80V CaPaCiTanCe...
Open the catalog to page 3All Seaward catalogs and technical brochures
-
PV150+
3 Pages
-
Seaward NTB-1
2 Pages
-
D255
2 Pages
-
PrimeTest 100
2 Pages
-
Solar Survey 100/200R Series
4 Pages
-
PrimeTest 50
2 Pages
-
00 Series
2 Pages
-
2018 Seaward PAT Selector
15 Pages
-
Cropico DO4000 Series
2 Pages
-
Cropico DO4A
2 Pages
-
SDR Series
1 Pages
-
Printers and Scanners
8 Pages
-
PR11
2 Pages
-
MTS
2 Pages
-
HAL Series
5 Pages
-
HAL LED
4 Pages
-
CR Series
1 Pages
-
Apollo+ Series
6 Pages
-
Seaward Manufacturing
12 Pages
-
PATGuard 3 PAT Testing Software
153 Pages
-
PrimeTest 250+ PAT Tester
4 Pages
-
Apollo 600
5 Pages
-
PrimeTest 250+
4 Pages
-
Apollo 400
5 Pages
-
Powercheck 1557
2 Pages
-
Apollo 500
20 Pages
-
Cropico RS3 Datasheet
2 Pages
-
Cropico RM6 Datasheet
1 Pages
-
Cropico RBC Datasheet
2 Pages
-
Cropico RBB Datasheet
2 Pages
-
Cropico CM5-N Datasheet
1 Pages
-
Cropico RM8 Datasheet
1 Pages
-
Cropico RM6N Datasheet
1 Pages
-
Cropico DO7010 Datasheet
2 Pages
-
Cropico DO7Plus Datasheet
2 Pages
-
Cropico DO6 Datasheet
2 Pages
-
Cropico DO7E Datasheet
2 Pages
-
Cropico DO7 Datasheet
2 Pages
-
PowerCheck 1557 Datasheet
2 Pages
-
PAT Checkbox Datasheet
2 Pages
Archived catalogs
-
Supernova Elite
2 Pages
-
Seaward Product
72 Pages
-
Powerplus 1557
4 Pages
-
PAT Testing Product
20 Pages
-
Cropico Product
48 Pages
-
ClareHAL
12 Pages
-
Clare Product
28 Pages
-
Calibrationhouse
2 Pages
-
Cropico DP6 Datasheet
2 Pages
-
Seaward PAT Testing Guide
20 Pages
-
Cropico DO5000-CS Datasheet
1 Pages
-
Cropico DO8000 Datasheet
2 Pages
-
Clare G2000 Datasheet
2 Pages
-
Clare B433R Datasheet
2 Pages
-
Clare Elite Datasheet
4 Pages
-
Clare B255 Datasheet
2 Pages
-
PrimeTest 300 Datasheet
2 Pages
-
SEN60204 Datasheet
22 Pages
-
SD 300 Datasheet
2 Pages
-
PrimeTest 250 Datasheet
2 Pages
-
Clare Horizon II Datasheet
2 Pages
-
Clare PowerSmart Datasheet
2 Pages
-
Clare A320 Datasheet
2 Pages
-
Clare Sentinel Datasheet
2 Pages
-
Clare HAL Combi Datasheet
2 Pages
-
Type L Plus Datasheet
2 Pages
-
PowerPlus 1557 Datasheet
2 Pages
-
Proving Units Datasheet
2 Pages
-
PowerGuard Pro Mobile 2
2 Pages
-
PowerGuard Pro 2 Datasheet
2 Pages
-
PATGuard Elite 2 Datasheet
2 Pages
-
Clare A252 Datasheet
1 Pages
-
Halo Hook Datasheet
2 Pages
-
IRT 1557 Datasheet
2 Pages
-
ERT 1557 Datasheet
2 Pages
-
VT800D Datasheet
2 Pages
-
VT800 Datasheet
2 Pages
-
PrimeTest 350 Datasheet
2 Pages
-
PATGuard Pro 2
2 Pages
-
PATGuard Lite 2
2 Pages
-
PATGuard Elements Datasheet
2 Pages
-
Test n Tag Datasheet
2 Pages
-
Supernova Plus Datasheet
2 Pages
-
PowerTest 1557 Datasheet
2 Pages
-
Guide to 17th Edition Testing
12 Pages
-
DM800/DM800R
1 Pages
-
Europa Plus PAT Tester
2 Pages
-
Supernova Plus PAT Tester
2 Pages