8004e

8004e
1 / 33 PagesView full catalog

8004e

Product catalog summary
Introduction
The DIO-32.PCIe User Manual by Sealevel Systems, Inc. provides detailed guidance on the installation, configuration, and operation of the DIO-32.PCIe digital I/O adapter. It is crucial for understanding the product's features, specifications, and installation procedures.
Product Description
The DIO-32.PCIe is a digital I/O interface card with 16 optically isolated inputs and 16 reed relay outputs, designed to protect equipment from electrical spikes and ground loop currents. It is compatible with Windows and Linux and includes SeaI/O Classic software for easy installation.
Features
  • PCI Express X1 compliant.
  • 16 optically isolated inputs with a configurable input range up to +30V.
  • 16 Reed relay outputs (SPST) with a maximum power rating of 10W.
  • Includes a 72” cable with DB78 Male to DB37 Male and Female connectors.
  • Supports multiple adapters in the same computer.
Electrical Specifications
  • Input Ports: Maximum input range of 3-13 VDC/VAC, with a maximum input current of 50 mA.
  • Output Relays: Maximum contact voltage of 60 VDC, contact current of 0.5A AC/DC RMS, and a rated life of up to 200 million closures for low load.
Technical Specifications
  • Dimensions: PCB Length 6.5” (16.5 cm), PCB Height 4.2” (10.7 cm).
  • Environmental: Operating temperature range from 0º to 70º C, storage from -50º to 105º C, and humidity range of 10 to 90% R.H. non-condensing.
Installation Instructions
Ensure the SeaI/O Classic software is installed before hardware installation. Insert the DIO-32.PCIe into a PCI Express slot and boot the computer. The system will configure the adapter using pre-installed drivers.
Verification
Check the Windows Device Manager under 'System Tools' to verify the digital I/O card is recognized.
Optional Items
Additional cables and terminal blocks are available for purchase to extend functionality, including DB37 and DB78 extension cables and terminal blocks.
Support and Warranty
The manual includes troubleshooting tips, technical support contact information, and warranty details. Assistance and RMA can be obtained through Sealevel's support channels.
Device Installation and Configuration
Instructions for installing and configuring the DIO-32.PCIe device are provided, including steps to verify correct installation and details on card assignments.
Digital I/O Interface
The DIO-32.PCIe features four parallel I/O ports: Ports A and B are input ports with optically-isolated inputs, while Ports C and D are reed relay output ports. Port addresses are provided in hexadecimal and decimal formats.
Programming and Software
Sealevel’s SeaI/O Classic software assists in developing applications for PCI and PCI Express digital I/O adapters, with driver functions, sample programs, and utilities for Windows and Linux.
Input Ports
Ports A and B are 8-bit input ports connected to optically isolated sensors, allowing voltage inputs to be sensed without risk of damage from ground loops. Details on input impedance and current requirements are provided.
Output Ports
Reed relays in Ports C and D provide high-quality, low-current switch closures. The document warns against using these relays for high-current applications.
Pin Assignments
Detailed pin assignments for input and output ports using DB-37 connectors are included, with guidance for users upgrading from older ISA boards.
Software Installation
Instructions for installing Sealevel software on Windows and Linux are provided. Windows users must install the software before connecting the hardware, while Linux users need to compile the software from source code.
Handling Instructions
Use electrostatically secure containers for transport, handle components when properly grounded, and use antistatic materials to prevent ESD damage.
Troubleshooting
Install software before hardware, verify installation using Device Manager, use provided utilities to test functionality, and contact technical support if issues persist.
Technical Support
Available Monday to Friday, 8:00 AM to 5:00 PM EST. Phone: +1 (864) 843-4343, Email: [email protected]
Compliance
The product complies with FCC Class A and EMC directives. Use provided or high-quality shielded cables to maintain compliance.
Warranty
Sealevel offers a Lifetime Warranty on I/O products, covering defects in materials and workmanship but excluding misuse or neglect.
See more

Catalog excerpts

8004e-1

DIO-32.PCIe User Manual USER MANUAL

 Open the catalog to page 1
8004e-4

Before You Get Started WHAT’S INCLUDED The 8004e is shipped with the following items. If any of these items are missing or damaged, please contact Sealevel for replacement. • 8004e – Board with 3-13V inputs 8004He – Board with 10-30V inputs DB78 Male to DB37 Male and DB37 Female V-cable (Item# CA165) ADVISORY CONVENTIONS Warning - The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury. Important– The middle level of importance used to highlight information that might not seem obvious or a situation that could...

 Open the catalog to page 4
8004e-5

Product Description The DIO-32.PCIe digital I/O interface provides 1 6 optically isolated inputs and 1 6 reed relay outputs. The inputs protect the PC and other sensitive equipment from spikes and ground loop current that can be generated in industrial environments, while the outputs provide high quality, long life, low current (1 0 Watt maximum), dry contact switch closures. Reed relays are well suited for low current applications. The relays are normally open, and close when energized. The SeaI/O Classic software drivers and utilities can be obtained from the Sealevel web site. They make installation...

 Open the catalog to page 5
8004e-6

Depending upon your application, you are likely to find one or more of the following items useful with the 8004e. All items can be purchased from our website (www.sealevel.com) by calling our sales team at (864) 843-4343. cables DB37 Terminal Block (Item# TB02) Break out serial and digital connectors to screw terminals for easy field connection. The TB02 terminal block is designed with both DB37 male and female connectors for interfacing the inputs or outputs.

 Open the catalog to page 6
8004e-7

Electrical Specifications features • 2 sets SPST relays with each having 8 relays • 2 eight bit input ports • DB-37 Male connector for relay outputs • DB-37 Female connector for optically isolated inputs • Highly reliable 10 VA reed relays • Multiple adapters can reside in same computer input ports Contact Max Power Rating

 Open the catalog to page 7
8004e-8

manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 1 00% electrically tested. These printed circuit boards are solder mask over bare copper or solder mask over tin nickel.

 Open the catalog to page 8
8004e-9

Hardware Installation Do not install the PCI Express board until the software has been successfully installed. The DIO-32.PCIe does not need to be configured prior to installation. Once you have installed the SeaI/O Classic software, install the board into an available PCI Express slot and boot the computer. The Found New Hardware wizard will appear. The drivers that were installed during the software installation process will automatically be used to configure the adapter. The following instructions are applicable to the Windows XP operating system and may vary depending on your version of Windows....

 Open the catalog to page 9
8004e-10

4. In right pane near the bottom, expand the ‘SeaI/O Device’ section by clicking the ‘+’ symbol. This shows the parent device is installed correctly. 5. You should see the card assignment listed as ‘SeaI/O 8004e’ with the card number in parentheses. The card number will increment for each additional SeaI/O device installed. Computer ■L nJ Disk drives Display adapters > ^ DVD/CD-ROM drives ■ flpj Human Interface Devices > IDE ATA/ATAPI controllers Mice and other pointing devices [>-L Monitors Network adapters |> -J, Sound, video and game controllers System devices ■■ i Universal Serial Bus...

 Open the catalog to page 10
8004e-11

The DIO-32.PCIe provides four parallel input/output (I/O) ports. The ports are organized as ports A, B, C, and D. Port A and B are input ports interfaced to optically-isolated inputs, while ports C and D are reed relay output ports. Assuming an I/O address of 4000 Hex the following table shows the Port Addresses.

 Open the catalog to page 11
8004e-12

Programming the DIO-32.PCI Sealevel’s SeaI/O Classic software is provided to assist in the development of reliable applications for the Sealevel Systems family of PCI and PCI Express digital I/O adapters. The SeaI/O Classic software is included on the CD that shipped with the board. The software contains driver functions for use in accessing the I/O as well as helpful samples and utilities. PROGRAMMING FOR WINDOWS The SeaI/O Classic API (Application Programmer Interface) provides a variety of useful high-level function calls implemented in a Windows dynamic link library (DLL). The API is defined...

 Open the catalog to page 12
8004e-13

resistor, and must also not overdrive the opto-isolator input current specification. The following formulas apply: Turn on Voltage = diode drop + (turn on current) x (resistance) [Ex: 1.1 + (.003) x R] Input Current = ((input voltage)-1.1V) / (resistor value) Maximum voltage = 1.1 + square root of (.25(resistor value))

 Open the catalog to page 13
8004e-14

The following table shows common input resistors and the ranges associated with each. The turn-off voltage for all resistors is less than IV. The opto-couplers require a minimum voltage to turn on and this voltage is dependent on the input resistor shown on the table above. Increasing the input resistor accordingly can increase the maximum input voltage. Because socketed DIP resistors are utilized, they can easily be replaced with a different value. Sealevel can do this, if necessary. The input circuits are not intended for monitoring 120-volt AC circuits. In addition to being too high a voltage...

 Open the catalog to page 14
8004e-15

Inputs are interfaced via the DB-37 female connector on the supplied CA1 65 cable. OThe CA1 65 cable input pin out is not compatible with the 3093 ISA digital I/O board. If you are upgrading from the 3093 and wish to preserve existing infrastructure wiring, order the CA378 cable.

 Open the catalog to page 15
8004e-16

Reed relays provide very high quality, long life, low current (1 0 Watt maximum), dry contact switch closures. Reed relays are not suited for high current applications, and can be destroyed by inductive load switching, where a spark occurs across the contacts internally. The relays are normally open, and close when energized. output ports creed relay) pin assignments cdb-37 male) Outputs are interfaced via the DB-37 male connector on the supplied CA165 cable.

 Open the catalog to page 16

All Sealevel Systems catalogs and technical brochures

  1. SeaIO Modules

    108  Pages

  2. eIO Manual

    46  Pages

  3. R91001

    78  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.