video corpo

V350U
6Pages

{{requestButtons}}

Catalog excerpts

V350U - 1

Performance class GENERAL CHARACTERISTICS Frequency (Hz) Standard Control Panel Optional control panel Optional Control Panel Optional control panel POWER Voltage Standby Amps Electronic governor Mechanically welded chassis with antivibration suspension Main line circuit breaker Radiator for core temperature of 48/50°C max with mechanical fan DIMENSIONS COMPACT VERSION Length (mm) 9 dB(A) silencer supplied separately Charger DC starting battery with electrolyte 24 V charge alternator and starter Protective grille for fan and rotating parts (CE option) Delivered with oil and coolant -30°C Manual for use and installation DIMENSIONS SOUNDPROOFED VERSION Type soundproofing POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed. Acoustic pressure level @1m in dB(A) Guaranteed acoustic power level (Lwa) Acoustic pressure level @7m in dB(A) According to the standard, the nominal power assigned by the genset is given for 25°C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINTY For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions . You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriated preventive measures. This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to improve the quality of its products. *ISO 8528.

Open the catalog to page 1
V350U - 2

ENGINE CHARACTERISTICS EXHAUST GENERAL ENGINE DATA Engine brand VOLVO Air inlet system Turbo Cylinders configuration L Charge Air coolant Air/Air DC Maximum stand-by power at rated 395 RPM (kW) 395 Frequency regulation, steady state (%) +/- 0.25% BMEP @ PRP 60 Hz (bar) 18,70 Governor type Electronic COOLING SYSTEM Max. exhaust back pressure (mm H2O) 1000 Fuel consumption 100% ESP load (L/hr) 93,40 Fuel consumption 100% load (L/hr) 85,80 Fuel consumption 75% PRP load (L/h) 64,10 Fuel consumption 50% PRP load (L/h) 44,20 Maximum fuel pump flow (L/h) 130...

Open the catalog to page 2
V350U - 3

OTHER DATA GENERAL DATA Single Bearing Number of Phase Power factor (Cos Phi) Altitude (m) Overspeed (rpm) Number of pole Capacity for maintaining short circuit at 3 ln for 10 s Insulation class T° class (H/125°), continuous 40°C T° class (H/163°C), standby 27°C Total Harmonic Distortion in no-load DHT (%) AVR Regulation Total Harmonic Distortion, on linear load DHT (%) Wave form : NEMA=TIF Wave form : CEI=FHT Coupling Direct Voltage regulation at established rating 0 50 (+/- %) 0,50 Recovery time (Delta U = 20% 500 transcient) (ms) Indication of protection IP 23 Continuous...

Open the catalog to page 3
V350U - 4

Acoustic pressure level @1m in dB(A) 86 Guaranteed acoustic power level (Lwa) 105 Acoustic pressure level @7m in dB(A) 76 13/11/2018 This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to improve the quality of its products. *ISO 8528.

Open the catalog to page 4
V350U - 5

CONTROL PANEL APM403, basic generating set and power plant control The APM403 is a versatile control unit which allows operation in manual or automatic mode Measurements : voltage and current kW/kWh/kVA power meters Standard specifications: Voltmeter, Frequency meter. Optional : Battery ammeter. J1939 CAN ECU engine control Alarms and faults: Oil pressure, Coolant temperature, Overspeed, Start-up failure, alternator min/max, Emergency stop button. Engine parameters: Fuel level, hour counter, battery voltage. Optional (standard at 24V): Oil pressure, water temperature. Event log/ Management...

Open the catalog to page 5
V350U - 6

TELYS, ergonomic and user-friendly The M80 is a dual-function control unit. It can be used as a basic terminal block for connecting a control box and as an instrument panel with a direct read facility, with displays giving a global view of your generating set's basic parameters. Offers the following functions: Engine parameters: tachometer, working hours counter, coolant temperature indicator, oil pressure indicator, emergency stop button, customer connection terminal block, CE. The highly versatile TELYS control unit is complex yet accessible, thanks to the particular attention paid...

Open the catalog to page 6

All SDMO catalogs and technical brochures

  1. J100U

    6 Pages

  2. J165K

    6 Pages

  3. J200K

    6 Pages

  4. V300U

    6 Pages

  5. V440C2

    5 Pages

  6. V500C2

    5 Pages

  7. D550

    6 Pages

  8. D700

    6 Pages

  9. D600U

    6 Pages

  10. V600UC2

    6 Pages

  11. T1400

    5 Pages

  12. T1540

    5 Pages

  13. T1350U

    5 Pages

  14. T2000U

    5 Pages

  15. T2500

    6 Pages

  16. T1900

    6 Pages

  17. Cogeneration

    2 Pages

  18. Containers

    2 Pages

  19. Rental power

    20 Pages

  20. Power products

    24 Pages

Archived catalogs

  1. Portable power

    16 Pages

  2. Portable Power

    36 Pages