video corpo

T1540
5Pages

{{requestButtons}}

Catalog excerpts

T1540 - 1

Engine ref. Alternator ref. Performance class GENERAL CHARACTERISTICS Standard Control Panel NA Optional control panel M80 Optional Control Panel APM403 Optional control panel APM802 Standby Amps DIMENSIONS COMPACT VERSION ^ 24 V charge alternator and starter Delivered with oil and coolant -30°C Manual for use and installation DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed. *DCC : Data Center Continuous Power ratings apply to Data Center installations where a reliable utility power is available and comply with Uptime institute Tier III and IV requirements. TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25°C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINTY For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions . You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriated preventive measures. Acoustic pressure level @1m in dB(A) 89 Sound power level guaranteed (Lwa) 110 Acoustic pressure level @7m in dB(A) 80 13/11/2018 This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to improve the quality of its products. *ISO 8528.

Open the catalog to page 1
T1540 - 2

ENGINE CHARACTERISTICS EXHAUST GENERAL ENGINE DATA Engine brand Engine ref. Air inlet system Cylinders configuration Number of cylinders Displacement (L) Charge Air coolant Bore (mm) x Stroke (mm) Compression ratio Maximum stand-by power at rated 1315 Frequency regulation, steady state (%) +/- 0.25% Governor type COOLING SYSTEM Max. exhaust back pressure (mm H2O) 600 Maximum fuel pump flow (L/h) 588 Oil system capacity including filters (L) 180 Radiator & Engine capacity (L) 300 HEAT BALANCE Heat rejection to exhaust (kW) 816 Fan power (kW) Fan air flow w/o restriction...

Open the catalog to page 2
T1540 - 3

OTHER DATA GENERAL DATA Single Bearing Number of Phase Power factor (Cos Phi) Altitude (m) Overspeed (rpm) Number of pole Capacity for maintaining short circuit at 3 ln for 10 s Insulation class T° class (H/125°), continuous 40°C T° class (H/163°C), standby 27°C AVR Regulation Total Harmonic Distortion in no-load DHT (%) Total Harmonic Distortion, on linear load DHT (%) Wave form : NEMA=TIF Wave form : CEI=FHT Coupling Direct Voltage regulation at established rating 0 50 (+/- %) 0,50 Recovery time (Delta U = 20% 500 transcient) (ms) Indication of protection IP 23 Continuous...

Open the catalog to page 3
T1540 - 4

Basic terminal block The control unit can be used as a basic terminal block for connecting a control box. The M80 is a dual-function control unit. It can be used as a basic terminal block for connecting a control box and as an instrument panel with a direct read facility, with displays giving a global view of your generating set's basic parameters. Offers the following functions: emergency stop button, customer connection terminal block, CE. Offers the following functions: Engine parameters: tachometer, working hours counter, coolant temperature indicator, oil pressure indicator, emergency...

Open the catalog to page 4
T1540 - 5

The APM403 is a versatile control unit which allows operation in manual or automatic mode Measurements : voltage and current kW/kWh/kVA power meters Standard specifications: Voltmeter, Frequency meter. Optional : Battery ammeter. J1939 CAN ECU engine control Alarms and faults: Oil pressure, Coolant temperature, Overspeed, Start-up failure, alternator min/max, Emergency stop button. Engine parameters: Fuel level, hour counter, battery voltage. Optional (standard at 24V): Oil pressure, water temperature. Event log/ Management of the last 300 genset events. Mains and genset protection Clock...

Open the catalog to page 5

All SDMO catalogs and technical brochures

  1. J100U

    6 Pages

  2. J165K

    6 Pages

  3. J200K

    6 Pages

  4. V300U

    6 Pages

  5. V350U

    6 Pages

  6. V440C2

    5 Pages

  7. V500C2

    5 Pages

  8. D550

    6 Pages

  9. D700

    6 Pages

  10. D600U

    6 Pages

  11. V600UC2

    6 Pages

  12. T1400

    5 Pages

  13. T1350U

    5 Pages

  14. T2000U

    5 Pages

  15. T2500

    6 Pages

  16. T1900

    6 Pages

  17. Cogeneration

    2 Pages

  18. Containers

    2 Pages

  19. Rental power

    20 Pages

  20. Power products

    24 Pages

Archived catalogs

  1. Portable power

    16 Pages

  2. Portable Power

    36 Pages