Catalog excerpts
J200K Engine ref. Alternator ref. Performance class GENERAL CHARACTERISTICS Standard Control Panel APM303 Optional control panel APM403 Optional Control Panel M80 Optional control panel TELYS Standby Amps DIMENSIONS COMPACT VERSION POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed. TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25°C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINTY For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions . You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriated preventive measures. DIMENSIONS SOUNDPROOFED VERSION Acoustic pressure level @1m in dB(A) 76 Sound power level guaranteed (Lwa) 95 Acoustic pressure level @7m in dB(A) 65 13/11/2018 This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to improve the quality of its products. *ISO 8528.
Open the catalog to page 1ENGINE CHARACTERISTICS EXHAUST GENERAL ENGINE DATA Engine brand Engine ref. Air inlet system Cylinders configuration Number of cylinders Displacement (L) Charge Air coolant Bore (mm) x Stroke (mm) Compression ratio Maximum stand-by power at rated 183 Frequency regulation, steady state (%) +/- 2.5% Governor type COOLING SYSTEM Max. exhaust back pressure (mm H2O) 750 Maximum fuel pump flow (L/h) 108 Oil system capacity including filters (L) 32 Radiator & Engine capacity (L) 25,80 HEAT BALANCE Heat rejection to exhaust (kW) 138 Fan power (kW) Fan air flow w/o restriction...
Open the catalog to page 2OTHER DATA GENERAL DATA Single Bearing Number of Phase Power factor (Cos Phi) Altitude (m) Overspeed (rpm) Number of pole Capacity for maintaining short circuit at 3 ln for 10 s Insulation class T° class (H/125°), continuous 40°C T° class (H/163°C), standby 27°C Total Harmonic Distortion in no-load DHT (%) AVR Regulation Total Harmonic Distortion, on linear load DHT (%) Wave form : NEMA=TIF Wave form : CEI=FHT Coupling Direct Voltage regulation at established rating 0 50 (+/- %) 0,50 Recovery time (Delta U = 20% 500 transcient) (ms) Indication of protection IP 23 Continuous...
Open the catalog to page 3Acoustic pressure level @1m in dB(A) Sound power level guaranteed (Lwa) Acoustic pressure level @7m in dB(A) Acoustic pressure level @1m in dB(A) Sound power level guaranteed (Lwa) Acoustic pressure level @7m in dB(A) This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to improve the quality of its products. *ISO 8528.
Open the catalog to page 4CONTROL PANEL The APM303 is a versatile unit which can be operated in manual or automatic mode. It offers the following features: Measurements: phase-to-neutral and phase-to-phase voltages, fuel level (In option : active power currents, effective power, power factors, Kw/h energy meter, oil pressure and coolant temperature levels) Supervision: Modbus RTU communication on RS485 Reports: (In option : 2 configurable reports) Safety features: Overspeed, oil pressure,coolant temperatures, minimum and maximum voltage, minimum and maximum frequency (Maximum active power...
Open the catalog to page 5TELYS, ergonomic and user-friendly The M80 is a dual-function control unit. It can be used as a basic terminal block for connecting a control box and as an instrument panel with a direct read facility, with displays giving a global view of your generating set's basic parameters. Offers the following functions: Engine parameters: tachometer, working hours counter, coolant temperature indicator, oil pressure indicator, emergency stop button, customer connection terminal block, CE. The highly versatile TELYS control unit is complex yet accessible, thanks to the particular attention paid...
Open the catalog to page 6All SDMO catalogs and technical brochures
-
INDUSTRIAL RANGE POWER PRODUCTS
26 Pages
-
J100U
6 Pages
-
J165K
6 Pages
-
V300U
6 Pages
-
V350U
6 Pages
-
V440C2
5 Pages
-
V500C2
5 Pages
-
D550
6 Pages
-
D700
6 Pages
-
D600U
6 Pages
-
V600UC2
6 Pages
-
T1400
5 Pages
-
T1540
5 Pages
-
T1350U
5 Pages
-
T2000U
5 Pages
-
T2500
6 Pages
-
T1900
6 Pages
-
Cogeneration
2 Pages
-
Containers
2 Pages
-
Moteurs semi-rapides
3 Pages
-
Rental power
20 Pages
-
Power products
24 Pages
-
Residential gensets
8 Pages
Archived catalogs
-
Portable power
16 Pages
-
Portable Power
36 Pages