Catalog excerpts
Industrial Diesel Generator Set – RATINGS 400 V - 50 Hz Standby kVA kWe kVA Data Center / Mission Critical kWe Prime kVA kWe Benefits & features KOHLER premium quality KOHLER provides one source responsibility for the generating set and accessories The generator set, its components and a wide range of options have been fully developed, prototype tested, factory built, and production tested The generator sets are designed in accordance to ISO8528 Approved for use with HVO (Hydrotreated Vegetable Oil) according to EN15940 KOHLER premium performances Engines High reliability enhanced through a simple design for optimal functional performances High performances turbochargers providing high engine performances under all loads Easy operation and maintenance: accessories requiring daily maintenance are conveniently located on the same side of the engine Alternator Provide industry leading motor starting capability Excitation system to permit sustained overcurrent > 300% In, during 10 sec Built with a class H insulation and IP23 Cooling A compact and complete solution using a mechanical or an electrical radiator fan (depending of genset type) High temperature and altitude product capacity available Control Panel The KOHLER wide controller range provides the reliability and performances you expect from your equipment. You can program, manage and diagnose it easily and in an efficient way KOHLER worldwide support A standard two-year or 1000-hours limited warranty for standby applications. A standard one-year or 2500 hours limited warranty for prime power applications. GENERAL SPECIFICATIONS Engine brand Alternator commercial brand Standard Control Panel Terminal block Optional control panel Optional Control Panel Optional control panel 429 Emission optimization - Low NOx (<=2000mg) Electrical driven fan Emission level Type of Cooling Performance class GENERATOR SETS RATINGS Data Center / Mission Critical kWe kVA DIMENSIONS COMPACT VERSION Length (mm) DIMENSIONS SOUNDPROOFED VERSION NA Type soundproofing Tank capacity (L) Dry weight (kg) Acoustic pressure level @1m in dB(A) 50Hz (75% PRP) Acoustic pressure level @7m in dB(A) 50Hz (75% PRP) A worldwide product support Reference Conditions: 25°C Air Inlet Temperature, 40°C Fuel Inlet Temperature, 100 kPa Barometric Pressure; 10.7 g/kg of dry air Humidity. Intake Restriction set to maximum allowable limit for clean filter; Exhaust Back pressure set to maximum allowable limit. Data was taken from a single engine test according to the test methods, fuel specification and reference conditions stated above and is subjected to instrumentation and engine-to-engine variability. Test conducted with alternate test methods, instrumentation, fuel or reference conditions can yield different results. Data and specifications
Open the catalog to page 1Industrial Diesel Generator Set – Engine General Engine brand Engine ref. Air inlet system Fuel Emission level Cylinder configuration Number of cylinders Displacement (l) Bore (mm) * Stroke (mm) Lubrication System MITSUBISHI Oil system capacity including filters (l) Diesel Fuel/HVO Emission optimization - Low NOx (<=2000mg) V 16 65,37 170 * 180 Air Intake system Max. intake restriction (mm H2O) Compression ratio Heat rejection to exhaust (kW) Maximum stand-by power at rated RPM (kW) Frequency regulation, steady state (%) Max. exhaust back pressure (mm H2O) Injection Type Governor type Air...
Open the catalog to page 2Industrial Diesel Generator Set – Alternator Standard Features Alternator Specifications Alternator commercial brand Kohler Alternator description Number of pole Number of bearing Technology Indication of protection 4 Single Bearing Brushless All models are brushless, rotating-field alternators NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting The AVR voltage regulator provides superior short circuit capability Insulation class Self-ventilated and dip proof construction Sustained short-circuit current of up to 300% of the rated current for up to 10...
Open the catalog to page 3Industrial Diesel Generator Set – Dimensions compact version Length (mm) * Width (mm) * Height (mm) Container dimensions ISO40 version Length (mm) * Width (mm) * Height (mm) Acoustic pressure level @1m in dB(A) 50Hz (75% PRP) Sound power level guaranteed (Lwa) 50Hz (75% PRP) Acoustic pressure level @7m in dB(A) 50Hz (75% PRP) Container dimensions CPU40 soundproofed version Length (mm) * Width (mm) * Height (mm) Acoustic pressure level @1m in dB(A) 50Hz (75% PRP) Sound power level guaranteed (Lwa) 50Hz (75% PRP) Acoustic pressure level @7m in dB(A) 50Hz (75% PRP) Container dimensions CPU40...
Open the catalog to page 4Industrial Diesel Generator Set – Basic terminal block It is used as a basic terminal block for connecting a control unit. Offers the following functions: emergency stop button customer connection terminal block CE certified The M80 is a dual-function control panel. It can be used as a basic terminal block for connecting a control unit and as an instrument panel with a direct read facility, with displays giving a global view of your generating set's basic parameters. Offers the following functions: Engine parameters: tachometer, working hours counter, coolant temperature indicator, oil...
Open the catalog to page 5Industrial Diesel Generator Set – STANDARD SCOPE OF SUPPLY All our gensets are fitted with: - Industrial water cooled DIESEL engine Radiator with coolant Electric starter & charge alternator 24 V D.C Electronic governor Standard air filter Single bearing alternator IP 23 T° rise/ insulation to class H/H Welded steel base frame with vibration attenuation mounts Flexible fuel lines & lub oil drain pump Exhaust outlet with flexible and flanges M80 control panel User’s manual (1 copy) Packing under plastic film Delivered with oil Delivered with antifreeze liquid CODES AND STANDARDS...
Open the catalog to page 6Industrial Diesel Generator Set – TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25°C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30% relative humidity. For particular conditions in your installation, refer to the derating table. WARRANTY INFORMATIONS Standard Warranty Period: - for Products in "back-up" service o 30 months from the date the Product leaves the plant o 24 months from the Product’s commissioning date o 1,000 running hours The warranty expires when one of the above conditions is met. for Products...
Open the catalog to page 7All SDMO catalogs and technical brochures
-
INDUSTRIAL RANGE POWER PRODUCTS
26 Pages
-
J100U
6 Pages
-
J165K
6 Pages
-
J200K
6 Pages
-
V300U
6 Pages
-
V350U
6 Pages
-
V440C2
5 Pages
-
V500C2
5 Pages
-
D550
6 Pages
-
D700
6 Pages
-
D600U
6 Pages
-
V600UC2
6 Pages
-
T1400
5 Pages
-
T1540
5 Pages
-
T1350U
5 Pages
-
T2000U
5 Pages
-
T2500
6 Pages
-
T1900
6 Pages
-
Cogeneration
2 Pages
-
Containers
2 Pages
-
Moteurs semi-rapides
3 Pages
-
Rental power
20 Pages
-
Power products
24 Pages
-
Residential gensets
8 Pages
Archived catalogs
-
Portable power
16 Pages
-
Portable Power