1. Catalogs
  2. SCR sa
  3. Ammonia Cracker

Ammonia Cracker
1 /1Page

Ammonia Cracker

Ammonia Cracker
1 /1Page

Catalog excerpts

Ammonia Cracker-1

Ammonia Cracker for gas of process and/or burning system 3 sizes: GCJM-1: 5.4 kW (horizontal) GCJM-2: 10.8 kW (vertical) GCJM-3: 21.6 kW (vertical) Technical characteristics • • • • • • • • Power supply : 3 x 400V Heating power : 5.4 / 10.8 / 21.6 kW Gas capacity : up to 17.5 m3 NH3 pure Touch screen regulator with integrated PLC : SCR3000 Safety temperature limiter : JUMO TB/TW Gas Inlet : 1/2’’ G Heating time : about 20 minutes from 20 to 950°C Dimensions : 720 x 740 x 1440 mm (GCJM-1) 2000* x 750** x 775 mm (GCJM-2) 2000* x 750** x 775 mm (GCJM-3) *Height +400mm with burner ** Width +175 with process gas cooler option Specifications For gas process • NH3 Inlet : 1.5 bar (with maximum 50 ppm H2O) Note: a filter before the ammonia inlet is recommended. • Residual ammonia in cracked gas < 200 ppm (<50 ppm in option) For burning system • Equipped with an electrical burner (3 controlled electrical sparks) Note: A saved power supply for the burner is recommended. • Environmental rejection conforms to European Norms and certified by Bureau Veritas and Apave. NH3 rejection level < 0.0042 g/hour (limit 10 g/h) NOx rejection level = 46.3 mg/Nm3 dry (limit 100 mg/Nm3 dry)

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.