The document provides technical specifications and features of the Integrated GCJM-2 Model Ammonia Cracker, designed for gas processing and burning systems. It outlines three available sizes: GCJM-1, GCJM-2, and GCJM-3, with varying power capacities.

Technical Characteristics
  • Power Supply: 3 x 400V
  • Heating Power: 5.4 kW (GCJM-1), 10.8 kW (GCJM-2), 21.6 kW (GCJM-3)
  • Gas Capacity: Up to 17.5 m3 NH3 pure
  • Touch Screen Regulator: Integrated PLC, model SCR3000
  • Safety Temperature Limiter: JUMO TB/TW
  • Gas Inlet: 1/2’’ G
  • Heating Time: Approximately 20 minutes from 20 to 950°C
  • Dimensions: GCJM-1: 720 x 740 x 1440 mm, GCJM-2 and GCJM-3: 2000 x 750 x 775 mm

Specifications for Gas Process
  • NH3 Inlet Pressure: 1.5 bar (maximum 50 ppm H2O)
  • Residual Ammonia in Cracked Gas: Less than 200 ppm (optional <50 ppm)

Specifications for Burning System
  • Equipped with an Electrical Burner: 3 controlled electrical sparks
  • Recommended: Saved power supply for the burner
  • Environmental Rejection: Conforms to European Norms, certified by Bureau Veritas and Apave
  • NH3 Rejection Level: Less than 0.0042 g/hour (limit 10 g/h)
  • NOx Rejection Level: 46.3 mg/Nm3 dry (limit 100 mg/Nm3 dry)
See more

Catalog excerpts

Ammonia Cracker-1

Ammonia Cracker for gas of process and/or burning system 3 sizes: GCJM-1: 5.4 kW (horizontal) GCJM-2: 10.8 kW (vertical) GCJM-3: 21.6 kW (vertical) Technical characteristics • • • • • • • • Power supply : 3 x 400V Heating power : 5.4 / 10.8 / 21.6 kW Gas capacity : up to 17.5 m3 NH3 pure Touch screen regulator with integrated PLC : SCR3000 Safety temperature limiter : JUMO TB/TW Gas Inlet : 1/2’’ G Heating time : about 20 minutes from 20 to 950°C Dimensions : 720 x 740 x 1440 mm (GCJM-1) 2000* x 750** x 775 mm (GCJM-2) 2000* x 750** x 775 mm (GCJM-3) *Height +400mm with burner ** Width +175 with process gas cooler option Specifications For gas process • NH3 Inlet : 1.5 bar (with maximum 50 ppm H2O) Note: a filter before the ammonia inlet is recommended. • Residual ammonia in cracked gas < 200 ppm (<50 ppm in option) For burning system • Equipped with an electrical burner (3 controlled electrical sparks) Note: A saved power supply for the burner is recommended. • Environmental rejection conforms to European Norms and certified by Bureau Veritas and Apave. NH3 rejection level < 0.0042 g/hour (limit 10 g/h) NOx rejection level = 46.3 mg/Nm3 dry (limit 100 mg/Nm3 dry)