Catalog excerpts
MODULE Mini-spectrometer TM series C10082MD, C10083MD For UV to near IR, integrating optical system, image sensor and circuit TM series mini-spectrometers are polychromators integrated with optical elements, an image sensor and a driver circuit. Two models are available: C10082MD (TM-UV/VIS-MOS) and C10083MD (TM-VIS/NIR-MOS). Light to be measured is guided into the entrance port of TM series through an optical fiber and the spectrum measured with the built-in image sensor is output from the USB port to a PC for data acquisition. No external power supply is required since USB bus power is used for circuit operation. The TM series comes with sample software, device driver and DLL. The sample software lets you easily set measurement conditions, acquire and save data, and display graphs. Features Applications l High throughput due to transmission grating made of quartz l Light source spectrum measurement l Sunlight or illumination analysis l Highly accurate optical characteristics l No external power supply required: Uses USB bus power l Absorbance measurement l Wide spectral response range l Easy to install into equipment l Wavelength conversion factor *1 is recorded in internal memory l Supports external trigger input *2 s Optical characteristics Parameter Spectral response range Spectral resolution Max. (Spectral response half width) * 3 Wavelength reproducibility * 4 Wavelength temperature dependence Spectral stray light * 3, * 5 s Electrical characteristics Parameter A/D conversion Integration time Interface USB bus power current consumption TM-UV/VIS-MOS C10082MD 200 to 800 TM-VIS/NIR-MOS C10083MD 320 to 1000 6 8 nm -33 nm nm/°C dB ±0.2 0.02 -35 Value 16 5 to 10000 USB1.1 100 Unit nm Unit bit ms mA s General ratings / Absolute maximum ratings Parameter Value Unit Dimensions 94 (W ) × 90 (D) × 55 (H) mm Image sensor CMOS linear image sensor (S8378-1024Q) Number of pixels 1024 pixels Slit * 6 70 (H) × 800 (V) µm Optical NA 0.22 Connector for optical fiber SMA905D Operating temperature * 7 +5 to +40 °C Storage temperature -20 to +70 °C *1: A conversion factor for converting the image sensor pixel number into a wavelength is recorded in the module. A calculation factor for converting the A/D converted count into the input light intensity is not provided. *2: Coaxial cable for external trigger input sold separately. Refer to the “Mini-spectrom eters Selection Guide” for details on external triggers. *3: Depends on the slit opening. Values were measured with the slit opening listed in the table. *4: Measured under constant light input conditions *5: W hen monochromatic light of the following wavelengths is input, spectral stray light is defined as the ratio of the count measured at the input wavelength, to the count measured in a region of the input wavelength ±40 nm. C10082MD: 500 nm, C10083MD: 650 nm *6: Entrance slit aperture size *7: No condensation 1
Open the catalog to page 1Mini-spectrometer TM series C10082MD, C10083MD s Optical component layout s Connection example (transmission light measurement) TM series mini-spectrometers use a transmission holographic grating made of quartz and precision optical components arranged on a rugged optical base, making it possible to deliver high throughput and highly accurate optical characteristics. Light to be measured is guided into the entrance port of TM series through an optical fiber and the spectrum measured with the built-in image sensor is output through the USB port to a PC for data acquisition. There are no...
Open the catalog to page 2Mini-spectrometer TM series s Measurement example Line spectra from LED were measured with C10082MD (TM-UV/VIS-MOS) C10082MD, C10083MD s Dimensional outline (unit: mm, tolerance unless otherwise noted: ±0.5) 94 (Typ. Ta=25 ˚C) 40000 Orange LED 17 ± 0.2 30.5 Red LED (2 ×) M3 tap depth 5 30000 90 40 ± 0.2 20000 15.5 AD count Blue LED 55 10000 0 200 300 400 500 600 700 800 Wavelength (nm) KACCA0171ED KACCB0126EA s Accessories · USB cable · Dedicated software (sample software, device driver, DLL) s Options (sold separately) · Coaxial cable for external trigger input A10670 · Optical fibers for...
Open the catalog to page 3Mini-spectrometer TM series n C10082MD, C10083MD Mini-spectrometer line-up Type No. Type C10082CAH TM-UV/VIS-CCD High resolution 400 600 800 1000 1200 1400 1600 1800 2000 2200 Spectral resolution Max. (nm) TM-UV/VIS-CCD High sensitivity C10082MD C10083CA TM series C10082CA Spectral response range (nm) 200 6 TM-UV/VIS-MOS Wide dynamic range 6 TM-VIS/NIR-CCD High sensitivity TM-VIS/NIR-CCD C10083CAH (λ=320 to 900 nm) 8 CMOS linear image sensor TG-UV-CCD High sensitivity 3 Back-thinned type CCD image sensor 1* Back-thinned type CCD image sensor 3 CMOS linear image sensor TG-UV-CCD TG series...
Open the catalog to page 4All Scitec Instruments catalogs and technical brochures
-
MPL-N-257
1 Pages
-
DCS500PA
1 Pages
-
C-995
2 Pages
-
360C
2 Pages
-
340CD
2 Pages
-
HPT-5100
2 Pages
-
FPM-250
2 Pages
-
FLS-1350
1 Pages
-
V-250
2 Pages
-
LTX-5525
2 Pages
-
LTX-5510
2 Pages
-
LTX-5520
2 Pages
-
LTX-510
1 Pages
-
TIA-4000
2 Pages
-
TIA-3000
2 Pages
-
TIA-1200
2 Pages
-
TIA-950
2 Pages
-
TIA-527
2 Pages
-
TIA-525
2 Pages
-
LTX-5515
2 Pages
-
LTS-1500
2 Pages
-
C995
2 Pages
-
360C OEM
2 Pages
-
350CD
2 Pages
-
300CD
2 Pages
-
IR Source Series 70
9 Pages
-
Infra Red Source Series 50
2 Pages
-
IR Source Series 40
1 Pages
-
IR Source Series 30
2 Pages
-
Infrared Source Series 20
6 Pages
-
IR Source Series 18-19
4 Pages
-
IR Source Series 12
6 Pages
-
Model 310CD
2 Pages
-
Optical Chopper
2 Pages
-
Energy Sensor Heads
2 Pages
-
Power Measuring
1 Pages
-
Motorized Filter Wheel
2 Pages
-
UV LOG USB and UV LOG 485
4 Pages
-
UVLOG
3 Pages
-
ZA - Laser with Ø 20mm
1 Pages
-
ZM-18H
2 Pages
-
Z-LASER - Laser for positioning
32 Pages
-
Laser – Powermeter
1 Pages
-
UV Probe Selection Process
3 Pages
-
CH 10
2 Pages