Omicron_DAR400_XM1000_V01_Apr07
8Pages

{{requestButtons}}

Catalog excerpts

Omicron_DAR400_XM1000_V01_Apr07 - 1

:_Nano Technology X-ray Photoelectron • High Flux for Rapid Analysis • Excellent Photon Linewidth for Peak Fitting Applications • Simple Self-Integration and Operation • Advanced Water-Cooling for Extended • Available with CASCADE Automation for ARXPS and High Sample Throughput

Open the catalog to page 1
Omicron_DAR400_XM1000_V01_Apr07 - 2

Introduction to X-Ray Sources X-ray Photoelectron Spectroscopy (XPS) is a routine surface analysis technique used to quantitatively analyse the chemical composition of the surface of a sample. For such studies two types of X-ray source exist the 'twin anode1 X-ray source for high speed, large area XPS and the 'monochromated' X-ray source for ultimate energy resolution. Other XPS techniques in which Omicron X-ray sources may be used include Angle Resolved XPS (AR-XPS), Depth Profiling, Multi-sample and large sample analysis and Small Area defined XPS (SAXPS). Omicron offers two dedicated...

Open the catalog to page 2
Omicron_DAR400_XM1000_V01_Apr07 - 3

XPS is one of the few techniques able to offer the researcher both elemental and chemical state information in a quantifiable form. Both twin anode and monochromated sources are able to provide standard XPS information but the use of monochromated X-rays may provide a number of research advantages for some operators. • Improved energy resolution; allowing the researcher to define the chemical peaks more precisely due to the narrower energy spread of the X-ray beam. A typical high per- formance monochromated X-ray source will have a photon line width of below 300meV, compared to ~850meV for...

Open the catalog to page 3
Omicron_DAR400_XM1000_V01_Apr07 - 4

DAR 400 Al window The DAR 400 is a twin anode X-ray source designed for high stability XPS performance with both Al K and Mg K radiation. The latest design philosophy offers the user: Anode fence Anode 1&2 • High power (up to 400 W) • Continuously adjustable anode voltage (up to 15 keV for sensitive damaged materials) • Minimal radiation cross talk (<0.35%) • Optional linear drive and port aligner for minimum working distance and multitechnique integration • Thoria-coated Tungsten cathodes, providing increased lifetime, stability and emission The DAR 400 is operated via the advanced digital...

Open the catalog to page 4
Omicron_DAR400_XM1000_V01_Apr07 - 5

XM 1000 The XM 1000 monochromated X-ray source is based on a compact 500mm diameter Rowland circle design, allowing it to be fully integrated into any ESCA solution with no compromises in performance or geometry. Quartz crystal x-ray mirror The XM 1000 offers leading performance with high photon brightness and a line width of below 0.25 eV. The Thoria coated Tungsten cathodes allow operation in high power line mode (600 W) and spot mode (300 W) delivering both high count rate and experimental exibility. Omicron’s 'All UHV' design philosophy means that the XM 1000 is thermally compensated to...

Open the catalog to page 5
Omicron_DAR400_XM1000_V01_Apr07 - 6

gjj Omicron X-ray 554 Control Windows™ 'drag-and- drop' technology allows control of their ESCA Optional Source Automation within CASCADE power supplies provide the user full software control over both X-ray sources, either individually ration of both sources using the 554-D digital supply provides the operator a space and cost saving, single digital interface and ensures accurate control of the anode cooling via a single recirculating water chiller. The new control software allows the user to operate either of the 554 series electronics remo- tely via PC interface including advanced...

Open the catalog to page 6
Omicron_DAR400_XM1000_V01_Apr07 - 7

DAR 400: Low Anode Cross Talk XM 1000 Al Ka Monochromator: High countrates at 0.460 eV FWHM Fermi edge of Silver at room temperature - 240 meV Omicron NanoTechnology GmbH

Open the catalog to page 7
Omicron_DAR400_XM1000_V01_Apr07 - 8

How to contact us Headquarters: Omicron NanoTechnology GmbH Limburger Str. 75 65232 Taunusstein, Germany Minneapolis Pittsburgh East Grinstead Linköping Moscow Poznan Beijing Seoul Tokyo Tel. +49 (0) 61 28 / 987 - 0 Fax +49 (0) 61 28 / 987 - 185 Web: www.omicron.de or www.omicron-instruments.com e-mail: info@omicron.de We have agents and partners worldwide – please check our website to nd your nearest contact. DAR 400 61 Taipei Mumbai Singapore Denver 275 Madrid St. Cannat Melbourne Rome Bucharest 300 / 350 Sales Sales & Service eadquarters XPS map of Pb4f7/2. The features in the array are...

Open the catalog to page 8

All Scienta Omicron catalogs and technical brochures

  1. NanoESCA

    4 Pages

  2. UHV Suitcase

    2 Pages

  3. ARPES-Lab

    4 Pages

  4. XPS-Lab

    2 Pages

  5. TESLA JT SPM

    8 Pages

  6. Argus CU

    7 Pages

  7. UHV NANOPROBE

    12 Pages

  8. Fermi SPM

    8 Pages

  9. Intellinova

    4 Pages

  10. MULTIPROBE

    8 Pages

  11. ISE 5

    2 Pages

  12. EKF 300

    2 Pages

  13. MBD-LEED

    8 Pages

  14. FOCUS PEEM

    16 Pages

  15. Argus

    12 Pages

  16. LT NANOPROBE

    8 Pages

  17. UHV STM 1

    2 Pages

  18. SPHERA

    8 Pages

  19. NanoSAM Lab

    6 Pages

Archived catalogs

  1. VT SPM

    11 Pages

  2. LT STM_2017

    16 Pages

  3. ESCA+_2010

    8 Pages

  4. VT SPM_2012

    20 Pages

  5. LT STM_2012

    16 Pages

  6. SPM PROBE

    2 Pages

  7. EFM 2

    8 Pages

  8. EKF 1000

    2 Pages

  9. SPECTALEED

    8 Pages

  10. CMA 100

    4 Pages

  11. NanoESCA

    8 Pages