Electrical Safety ® Compliance Simplified. Hipot • Insulation Resistance • Ground Bond • Multi-Function Electrical Safety Toll Free +1-800-504-0055

Open the catalog to page 1
SCI Catalog 2022 - 2

We've been providing Customers with the features they have needed for over 60 years. We aim to simplify the Electrical Safety Industry for our Customers by applying this philosophy to everything we do. All testers come with the accessories you need to run a test right out of the box. PRODUCT SELECTION GUIDE Insulation Resistance Ground Continuity Check Electrical Safety Compliance Simplified.® Frequency Selection

Open the catalog to page 2
SCI Catalog 2022 - 3

CUSTOMER HAPPINESS PROMISE We aim to provide an amazing experience and quality testers that last a long time. If you’re not satisfied with your tester, return it within 45 days for a full refund. Calibrate annually with us, or one of our authorized partners, and we’ll extend your warranty an additional year for the service life of your tester, and at least five years after discontinuation. If it breaks during that time, we promise to fix it for free (unless abuse or excessive damage is present). When your tester reaches the end of its service life, we’ll responsibly recycle it and give you...

Open the catalog to page 3
SCI Catalog 2022 - 4

VERSATILE 4-IN-1 FUNCTIONALITY INTUITIVE USER INTERFACE 40A GROUND BOND CAPABILITY 20 PROGRAMMABLE MEMORIES The 440 Series provides advanced 4-in-1 test capability in a convenient one-box solution. This new series performs AC Hipot (448 - 500 VA), DC Hipot, Insulation Resistance and 40A AC Ground Bond tests while taking up minimal production line space. The 440 Series is simple and easy-to-use; reducing setup time and increasing production line throughput for your application. With multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a...

Open the catalog to page 4
SCI Catalog 2022 - 5

440 SERIES SPECS FOUND ON PAGE 10 & 11 RELEVANT APPLICATIONS SERIES FEATURES CONTRACT MANUFACTURING INDUSTRIAL EQUIPMENT INFORMATION TECHNOLOGY Test Setup Memories Fuse 15A Fast Blow 30mm - *448 Model Interlock Connector Male Ground Bond Test Lead Ground Bond Return Lead High Voltage Test Lead 6ft Safety Agency Listed Fuse 10A Slow Blow 20mm - *446 Model Power Cord (15A) 6ft - *448 Model Power Cord (10A) 6ft - *446 Model Frequency Selection All testers come with the accessories you need to run a test right out of the box. OPTIONS Description Rear Outputs Intuitive User Interface

Open the catalog to page 5
SCI Catalog 2022 - 6

HIPOT TESTERS RoHS 3 5 PROGRAMMABLE MEMORIES WITH 10 OPTIONAL EASILY AUTOMATE FOR DATA COLLECTION ADVANCED SECURITY SETTING The 290 Series is our most popular line of Hipot testers. These testers are designed to simplify every aspect of safety testing for operators of all comfort levels. Our 290 Series includes the most intuitive user interface in the industry and won’t take up too much space on the production line. With multiple memories and an optional USB interface, you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Choose from 5 different models to...

Open the catalog to page 6
SCI Catalog 2022 - 7

290 SERIES SPECS FOUND ON PAGE 12 RELEVANT APPLICATIONS SERIES FEATURES APPLIANCE AC/DC POWERED PRODUCTS CABLES & COMPONENTS Test Setup Memories Frequency Selection Safety Agency Listed MODULAR HOMES MOTORS & PUMPS High Voltage Lead 6 ft. (1.8m) Input Power Cable USA Interlock Connector All testers come with the accessories you need to run a test right out of the box. OPTIONS Description Rear Outputs USB Port 10 Memory 3mA Current Limit Pulse Mode Push to Test Mode

Open the catalog to page 7
SCI Catalog 2022 - 8

GROUND BOND TESTERS RoHS 3 5 PROGRAMMABLE MEMORIES EASILY AUTOMATE FOR DATA COLLECTION ADVANCED SECURITY SETTINGS Our 260 Series makes Ground Bond testing simple. Choose between two easy-to-use Ground Bond testers that provide the output current to satisfy NRTL specifications. With an intuitive interface that allows you to set-up a test in seconds and practical security settings, our 260 Series can easily be deployed in both laboratory and production line environments. MILLIOHM OFFSET FUNCTION FOR ACCURATE GROUND BOND TESTING REDUNDANT HARDWARE SAFETY INTERLOCK PORTABLE, RUGGED DESIGN...

Open the catalog to page 8
SCI Catalog 2022 - 9

260 SERIES SPECS FOUND ON PAGE 13 RELEVANT APPLICATIONS SERIES FEATURES APPLIANCE INDUSTRIAL EQUIPMENT MEDICAL LABORATORY EQUIPMENT Test Setup Memories Frequency Selection WATER PUMPS Safety Agency Listed 40 Amp High Current Return Lead 6ft. (1.8m) 40 Amp High Current Lead 6ft. (1.8m) Input Power Cable USA Interlock Connector 60 Amp High Current Lead 6 ft. (1.8m) 60 Amp High Current Return Lead 6 ft. (1.8m) Input Power Cable USA Interlock Connector All testers come with the accessories you need to run a test right out of the box. Rear Outputs Intuitive User Interface USB Port Display...

Open the catalog to page 9
SCI Catalog 2022 - 10

440 SERIES SPECIFICATIONS INPUT (446 and 448) DIELECTRIC WITHSTAND TEST MODE (Cont.) Output Regulation DIELECTRIC WITHSTAND TEST MODE Output Rating Range: 0 - 20.00 mA AC, 0 - 5.00 mA DC Resolution: 0.01 mA Accuracy: ± (2% of reading + 0.02 mA) Range: 0 - 99.99 mA AC, 0 - 10.00 mA DC Resolution: 0.01 mA Accuracy: ± (2% of reading + 0.06 mA) Range: Lo-Limit 0 - 20.00 mA, Hi-Limit 0.10 – 20.00 mA Resolution: 0.01 mA Accuracy: ± (2% of setting + 2 counts) Range: Lo-Limit 0 - 5.00 mA, Hi-Limit 0.02 – 5.00 mA Resolution: 0.01 mA Accuracy: ± (2% of setting + 2 counts) Range: Lo-limit 0 - 99.99...

Open the catalog to page 10
SCI Catalog 2022 - 11

440 SERIES SPECIFICATIONS GROUND BOND Output AC Current, A GENERAL SPECIFICATIONS Range: Resolution: Accuracy: Allows storage of up to 20 different test programs and a single step mode Test, Reset, Interlock & Recall Memory 1–6 Pass, Fail, Test-in-Process Maximum Loading Offset, mΩ Range: Resolution: Accuracy: Range: Resolution: Accuracy: Fix Ramp Timer, second Range: Resolution: Accuracy: Range: Resolution: Accuracy: Range: Resolution: Accuracy Interface Security USB (Optional) Lockout capability to avoid unauthorized access to test set-up programs Software and adjustments made through the...

Open the catalog to page 11
SCI Catalog 2022 - 12

INSULATION RESISTANCE TEST MODE (297 only) Output Voltage Range: Resolution: Accuracy: Resistance Display Range: Resolution: Accuracy: Range: Resolution: Range: Resolution: Ramp: Delay: DIELECTRIC WITHSTAND TEST MODE Output Rating 0-5.00 kVAC Resolution: 0.01 kV Accuracy: ± (1.5% of setting + 5V) 0-6.00 kVDC Resolution: 0.01 kV Accuracy: ± (1.5% of setting + 5V) Output Frequency Voltage Setting GENERAL SPECIFICATIONS Continuity Feature Range: Resolution: Accuracy: Input: Output: Test, Reset, Interlock Pass, Fail, Test-in-Process Hardware Interlock - a relay on the high voltage output opens...