SEL-2245-4 AC Metering Module
4Pages

{{requestButtons}}

Catalog excerpts

SEL-2245-4 AC Metering Module - 1

SEL-2245-4 AC Metering Module The SEL-2245-4 provides ac metering inputs for the SEL Axion®. Within an Axion node, install as many as sixteen SEL-2245-4 modules per system in any combination you want. Front Panel Mechanical Installation Each SEL-2242 chassis/backplane has four or ten slots, labeled A–J. Slots B–J support the SEL-2245-4 modules. Schweitzer Engineering Laboratories, Inc. Notch for Module Alignment To install an SEL-2245-4 module, tip the top of the module away from the chassis, align the notch on the bottom of the module (shown in Figure 2) with the slot you want on the chassis, and place the module on the bottom lip of the chassis as Figure 3 illustrates. The module is aligned properly when it rests entirely on the lip of the chassis.

Open the catalog to page 1
SEL-2245-4 AC Metering Module - 2

Configure inputs by adding a Fieldbus I/O connection for each module in ACSELERATOR RTAC® SEL-5033 Software. See the EtherCAT® portion in Section 2: Communications in the SEL-5033 software manual for details. Proper Module Placement Next, carefully rotate the module into the chassis, making sure that the alignment tab fits into the corresponding slot at the top of the chassis (refer to Figure 4). Finally, press the module firmly into the chassis and tighten the chassis retaining screw. CT/PT Analog Inputs Final Module Alignment Input Connections The SEL-2245-4 CT/PT analog inputs include a...

Open the catalog to page 2
SEL-2245-4 AC Metering Module - 3

Specifications Range: Typical Accuracy: ISO 9001:2008 Certified UL/cUL: NRAQ, NRAQ7 per UL508, and C22.2 No. 14 Worst Case Accuracy: Sequence Components Operating Temperature Range –40° to +85°C (–40° to +185°F) Operating Environment Typical Accuracy Magnitude: Pollution Degree: Overvoltage Category: Relative Humidity: Maximum Altitude: Power and Power Factor (Per Phase and Three-Phase) Typical Accuracy: Synchrophasor Conformance: IEEE C37.118.1-2011 as amended by IEEE C37.118.1a-2014 Level 1 as specified by IEEE C37.118 Typical Accuracy: Software selectable Worst Case Accuracy: Phase...

Open the catalog to page 3
SEL-2245-4 AC Metering Module - 4

Damp Heat, Cyclic: IEC 60068-2-30:2005 25°C to 55°C, 6 cycles, 95% relative humidity Magnetic Field Immunity: IEC 61000-4-8:2009 Severity Level: 1000 A/m for 3 seconds, 100 A/m for 1 minute IEC 61000-4-9:2001 Severity Level: 1000 A/m IEC 61000-4-10:2001 Severity Level: 100 A/m Surge Withstand Capability Immunity: IEC 60255-22-1:2007 Severity Level: 2.5 kV common-mode 1.0 kV differential-mode IEEE C37.90.1-2002 Severity Level: 2.5 kV Oscillatory 4.0 kV Fast Transient Oscillatory Waves Immunity: IEC 61000-4-12:2006 Severity Level: Ring Wave: 2 kV common, 1.0 kV differential Oscillatory: 2.5...

Open the catalog to page 4

All Schweitzer Engineering Laboratories catalogs and technical brochures

  1. SEL-C662

    1 Pages

  2. 2019 CATALOG

    248 Pages

  3. 2018 CATALOG

    374 Pages

Archived catalogs