The SEL-2244 provides contact input and outputs for the SEL Axion' . Within an Axion node, install any combination Front Panel Mechanical Installation Figure 1 SEL-2244 Digital Input and Output Modules Each SEL-2242 chassis/backplane has ten slots, labeled A through J. Slots B^J support the SEL-2244 Digital Input and Digital Output modules. Figure 2 Notch for Module Alignment To install an SEL-2244 module, tip the top of the module away from the chassis, align the notch on the bottom of the module (shown in Figure 2) with the slot you want on the chassis, and place the module on the bottom lip of the chassis as Figure 3 illustrates. The module is aligned properly when it rests entirely on the lip of the chassis. Schweitzer Engineering Laboratories, Inc.
Open the catalog to page 1
EtherCAT® portion in the Section 2: Communications in the ACSELERATOR RTAC SEL-5033 Instruction Manual for details. NOTE: Ensure that when you are applying ac power to inputs with common returns that ac neutral is connected to the common terminal. Digital Inputs Proper Module Placement Next, carefully rotate the module into the chassis, making sure that the alignment tab fits into the corresponding slot at the top of the chassis (refer to Figure 4). Finally, press the module firmly into the chassis and tighten the chassis retaining screw. Refer to the Specifications on page 3 for output...
Open the catalog to page 2
Operating Temperature Range Continuous Carry: Continuous Carry (UL/CSA derating with all outputs asserted): 5 A @ < 60°C; 2.5 A 60 to 70°C –40° to +85°C (–40° to +185°F) Note: Not applicable to UL applications. Thermal: Pollution Degree: Overvoltage Category: Relative Humidity: Maximum Altitude: Optoisolated Control Inputs (SEL-2244-2) When Used With DC Control Signals: 250 Vdc Operating Time (coil energization to contact closure, resistive load): Pickup/Dropout time 8 ms typical Breaking Capacity 24 Vdc (10,000 operations) per 48 Vdc IEC 60255-0-20:1974: 125 Vdc 250 Vdc Cyclic Capacity...
Open the catalog to page 3
Contact Protection: 330 Vdc, 145 J MOV protection across open contacts Operating Time (coil energization to contact closure, resistive load): Pickup time: 12 µs at 250 Vdc, 16 µs at 125 Vdc, 65 µs at 19.2 Vdc typical (results with 100 k resistive load) Dropout time: Dielectric Strength and Impulse Tests Impulse: IEC 60255-5:2000 Severity Level: 0.5 Joule, 5 kV IEEE C37.90-2005 Severity Level: 0.5 Joule, 5 kV Dielectric (HiPot): IEC 60255-5:2000 Severity Level: 2500 Vac on contact inputs and outputs for 1 minute. IEEE C37.90-2005 Severity Level: 2500 Vac on contact inputs and outputs for 1...
Open the catalog to page 4
ISO 9001: This product was designed and manufactured under an ISO 9001 certified quality management system. Schweitzer Engineering Laboratories, Inc.
Open the catalog to page 5
Schweitzer Engineering Laboratories, Inc.
Open the catalog to page 6
Schweitzer Engineering Laboratories, Inc. SEL-2244 Data Sheet
Open the catalog to page 7
© 2011–2013 by Schweitzer Engineering Laboratories, Inc. All rights reserved. All brand or product names appearing in this document are the trademark or registered trademark of their respective holders. No SEL trademarks may be used without written permission. SEL products appearing in this document may be covered by U.S. and Foreign patents. SCHWEITZER ENGINEERING LABORATORIES 2350 NE Hopkins Court • Pullman, WA 99163-5603 USA Phone: +1.509.332.1890 • Fax: +1.509.332.7990 Internet: www.selinc.com • E-mail: info@selinc.com Schweitzer Engineering Laboratories, Inc. reserves all rights and...
Open the catalog to page 8All Schweitzer Engineering Laboratories catalogs and technical brochures
-
SEL-C662
1 Pages
-
2019 CATALOG
248 Pages
-
2018 CATALOG
374 Pages
-
METERING ACCESSORIES CATALOG
20 Pages
-
STANDARD CABINET CATALOG
28 Pages
-
SEL-3622 Security Gateway
12 Pages
-
SEL-710-5 Motor Protection Relay
28 Pages
-
SEL-3610 Port Server
12 Pages
-
2017 SEL Catalog
373 Pages
-
SEL-2664 Field Ground Module
12 Pages
-
SEL-2533 Annunciator
12 Pages
-
SEL-2414 Transformer Monitor
20 Pages
-
SEL-2243 Power Coupler
4 Pages
-
SEL-2242 Chassis/Backplane
8 Pages
-
SEL-2240 Axion®
32 Pages
-
SEL-1102 Computing Platform
12 Pages
Archived catalogs
-
2015 Modern Solutions Catalog
331 Pages
-
SEL 2008 Product Catalog EOS Mfg
44 Pages