video corpo cad

DG11
7Pages

{{requestButtons}}

Catalog excerpts

DG11 - 1

Power entry modules without line filter https://www.schurter.com /PG05 Screw-on with IP67 and TA35 in white with black Screw-on with IP67 Snap-in IP40 with TA35 red illuminated and em- printed symbols bossed symbols See below: Approvals and Compliances Description - Panel mount : Screw-on version from front or rear side, snap-in version from front side - 2 Functions : Appliance Inlet , protection class I or II , Circuit breaker type TA35 , 2-pole - Pre-wired coupling - V-Lock notch standard - Quick connect terminal 6.3 x 0.8 mm Unique Selling Proposition - Variant tested for IP67 into the appliance - Various mounting options - Recessed rocker prevents accidental manipulation - Compatible with V-Lock cord retention Characteristics - Connector and circuit breaker are prewired - Circuit Breaker non-illuminated or illuminated - Suitable for use in equipment according to IEC/UL 60950 Other versions on request - Version without pre-wiring from inlet to circuit breaker - Protection class II, 70°C - Variants in white References Substitute for type 6135 Component: circuit breakers TA35 Rocker 2Pole Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor-Stock-Check, Accessories, Detailed request for product, Landing Page Technical Data Ratings IEC 10 A/250 VAC; 50 Hz Ratings UL/CSA15 A/250 VAC; 60 Hz Dielectric Strength > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) Allowable Operation Tempe- -25 °C to 60 °C rature IP-Protection from front side IP40 or IP67 acc. to IEC 60529 Insulation cover Suitable for appliances with protection class I or II acc. to IEC 61140 TerminalQuick connect terminals 6.3 x 0.8 mm Panel Thickness S Screw: max 8 mm Recommended torque min 0.25 Nm Snap-in : S =1/1.2/1.5/2/2.5/3 mm Material: HousingThermoplastic, black, UL 94V-0 UL 60320-1, CSA C22.2 no. 60320-1 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or non-illuminated. Conditional short circuit Inc: 2000 A Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DG11 Certificates VDE Approvals UL Approvals CQC Approvals Certification Body Description UL UL File Number: E96454 CQC CCC Certificate Number: pending ELECTRONIC COMPONENTS

Open the catalog to page 1
DG11 - 2

Power entry modules without line filter https://www.schurter.com /PG05 Product standards Product standards that are referenced Design Designed according to Designed according to Designed according to Standard Description IEC 60320-1 Appliance couplers for household and similar general purposes UL 60320-1 Standard for Attachment Plugs and Receptacles CSA C22.2 no. 60320-1 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Designed for applications...

Open the catalog to page 2
DG11 - 3

Power entry modules without line filter https://www.schurter.com /PG05 Screw-on mounting version A for front mount IP40 5.65 Screw-on mounting Version A for rear mount IP40 (51.6) Screw-on mounting Version B for front mount IP40

Open the catalog to page 3
DG11 - 4

Power entry modules without line filter https://www.schurter.com /PG05 Screw-on mounting version B for rear mount IP40 Screw-on mounting for front mount IP67 Example: Rated current = 5 A, Environmental temperature = 50 °C --> Correction factor = 1.04, Resulting current = 5.2 A --> Fount to next higher rated current: 6 A ELECTRONIC COMPONENTS

Open the catalog to page 4
DG11 - 5

Power entry modules without line filter https://www.schurter.com /PG05 Multiple of Rated Current In Reference Temperature +23° Multiple of Rated Current In Reference Temperature +23°

Open the catalog to page 5
DG11 - 6

Power entry modules without line filter https://www.schurter.com /PG05 ORDER CODE Number of switched poles Number of protected poles Table 1 Selection for type TA35 Order example Switch without illumination Switch illuminated 240 V 120 V Colours Switch front Rocker non-illuminated illuminated - red transparent - green transparent - orange transparent Other colours on request Colour of print white black white black Rocker legend Surface Illustration F embossed - ° Other legends on request Position of the rocker legend e.g. I / O Other rated currents on request *) UL /...

Open the catalog to page 6
DG11 - 7

Power entry modules without line filter https://www.schurter.com /PG05 Please note that Schurter will establish an internal part number for logistics use in addition to the order code. The format of this internal part number is, for example: 3-XXX-XXX 00 Screw version A front mounting 01 Screw version B front mounting 02 Screw version A rear mounting 03 Screw version B rear mounting 88 Screw version front mounting (sealed towards housing, IP67) All Variants Config. Code Availability for all products can be searched real-time:...

Open the catalog to page 7

All SCHURTER catalogs and technical brochures

  1. FMAD NEO

    6 Pages

  2. THS

    5 Pages

  3. TTS

    4 Pages

  4. Product News

    4 Pages

  5. FMAB NEO

    12 Pages

  6. FPG1

    4 Pages

  7. FMAB HV

    6 Pages

  8. UMT-W

    4 Pages

  9. OGN

    3 Pages

  10. 0712

    3 Pages

  11. CPS

    7 Pages

  12. DG12

    10 Pages

  13. 4751

    4 Pages

  14. FMAD CP

    4 Pages

  15. 4783

    4 Pages

  16. EF11

    8 Pages

  17. PFRY

    4 Pages

  18. PFRA

    6 Pages

  19. PFMF

    4 Pages

  20. PFHT

    3 Pages

  21. PFDF

    3 Pages

  22. 6051.2067

    3 Pages

  23. 6051.2068

    3 Pages

  24. 4797-5

    4 Pages

  25. 6051.2063

    3 Pages

  26. 6051.2061

    3 Pages

  27. 6051.2015

    3 Pages

  28. 3-108-993

    2 Pages

  29. 3-100-361

    3 Pages

  30. GP21

    3 Pages

  31. FMER SOL

    10 Pages

  32. CMF2, CMF5

    3 Pages

  33. CDS1

    5 Pages

  34. DKIH-3

    6 Pages

  35. 4710-5

    5 Pages

  36. Touchkit

    3 Pages

  37. USN 1206

    3 Pages

  38. FPBB RAIL

    7 Pages

  39. DD14

    8 Pages

  40. VAC19KS

    3 Pages

  41. UMK 250

    4 Pages

  42. 4761

    3 Pages

  43. 4732

    4 Pages

  44. FUS

    3 Pages

  45. DKIH

    6 Pages

  46. FSO

    2 Pages

  47. CSO

    3 Pages

  48. CMF1, CMF4

    3 Pages

  49. FMAC NEO

    5 Pages

  50. MSM DP 30

    8 Pages

  51. PSE AE 16

    3 Pages

  52. MSM LA CS 22

    7 Pages

  53. MSM LA CS 19

    6 Pages

  54. PSE AE 30

    5 Pages

  55. PSE EX 16

    5 Pages

  56. PSE EX 19

    5 Pages

  57. PSE NO 19

    6 Pages

  58. PSE NO 16

    6 Pages

  59. PSE EX 22

    5 Pages

  60. PSE NO 27

    6 Pages

  61. PSE NO 24

    6 Pages

  62. PSE NO 22

    8 Pages

  63. PSE IV 16

    6 Pages

  64. PSE HI 22

    6 Pages

  65. PSE NO 30

    7 Pages

  66. PSE M22 IV

    7 Pages

  67. MCS ES 18

    3 Pages

  68. MCS ES 22

    3 Pages

  69. 6051.2094

    3 Pages

  70. 6051.2093

    3 Pages

  71. 6051.2078

    3 Pages

  72. 6051.2077

    3 Pages

  73. 6051.2070

    3 Pages

  74. 6051.2072

    3 Pages

  75. 6051.2071

    3 Pages

  76. 6051.2037

    2 Pages

  77. 6051.2030

    3 Pages

  78. 6051.2032

    3 Pages

  79. 6051.2031

    3 Pages

  80. 6051.2027

    3 Pages

  81. 3-107-570

    2 Pages

  82. 3-107-569

    2 Pages

  83. VAC13KS

    4 Pages

  84. DD21

    5 Pages

  85. DD11

    5 Pages

  86. DF11

    6 Pages

  87. typ_4762

    3 Pages

  88. SWA2

    2 Pages

  89. PB 1021

    2 Pages

  90. TM12-111

    6 Pages

  91. PTS

    4 Pages

  92. PB 1011

    2 Pages

  93. FMAD CEE

    3 Pages

Archived catalogs

  1. Product News

    4 Pages

  2. PFDF

    3 Pages

  3. PFHT

    3 Pages

  4. PFUF

    3 Pages

  5. DKFP

    5 Pages

  6. FMAD RAIL

    3 Pages

  7. FMAC RAIL

    3 Pages

  8. FMBD NEO

    6 Pages

  9. FMAC SINE

    4 Pages

  10. FMAB RAIL

    3 Pages

  11. FMBB NEO

    11 Pages

  12. FMBB RAIL

    3 Pages

  13. 5120

    10 Pages

  14. SMD-FTT

    1 Pages

  15. OMZ 125

    1 Pages

  16. 4840.2200

    2 Pages

  17. 6051.5003

    2 Pages

  18. 6000.0224

    2 Pages

  19. 6051.2030

    2 Pages

  20. 6051.2003

    2 Pages

  21. FLBB

    2 Pages

  22. 4741

    2 Pages

  23. P685

    2 Pages

  24. KE

    4 Pages

  25. GSF2

    4 Pages

  26. GSF1

    5 Pages

  27. Felcom 64

    4 Pages

  28. 6135

    5 Pages

  29. DC21

    3 Pages

  30. 1074

    4 Pages

  31. DC11

    5 Pages

  32. CMF3, CMF6

    2 Pages

  33. PFNF

    3 Pages

  34. ESO 10.3x38

    1 Pages

  35. SHT 6.3x32

    1 Pages

  36. KEB2

    1 Pages

  37. ASO / FSO

    8 Pages

  38. Varistors

    40 Pages

  39. Flyer MGA-S

    6 Pages