video corpo cad

DF11
6Pages

{{requestButtons}}

Catalog excerpts

DF11 - 1

Power entry modules without line filter https://www.schurter.com /PG05 IEC Appliance Inlet C14 or C18 with recessed Circuit Breaker TA45 See below: Approvals and Compliances Description - Panel mount : Screw-on version from front or rear side, snap-in version from front side - 2 Functions : Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole - Quick connect terminals 6.3 x 0.8 mm Characteristics - All single elements are already wired - Circuit Breaker non-illuminated or illuminated - Suitable for use in equipment according to IEC/UL 60950 Other versions on request - Unwired versions - Other rocker marking - Variant with notch for V-Lock mating Cordsets References Alternative: version with line filter DF12 Substitute for type 6145 Weblinks pdf datasheet, html-datasheet, General Product Information, Distributor-Stock-Check, Accessories, Detailed request for product, Microsite Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC 10 A/250 VAC; 50 Hz Ratings UL/CSA15 A/250 VAC; 60 Hz Dielectric Strength > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) Allowable Operation Tempe- -10 °C to 55 °C rature IP-Protectionfrom front side IP 40 acc. to IEC 60529 Insulation cover Suitable for appliances with protection class I or II acc. to IEC 61140 TerminalQuick connect terminals 6.3 x 0.8 mm Panel Thickness S Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1/1.5/2/2.5/3 mm Material: HousingThermoplastic, black, UL 94V-0 UL 60320-1, CSA C22.2 no. 60320-1 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II Circuit Breakers Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or non-illuminated. Optional with undervoltage-or remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 2 3A/240VAC : 300A Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DF11 Approval Logo cTOus Certificates VDE Approvals UL Approvals Certification Body Description UL UL File Number: E96454 Connectors H.SCHURTER 1 ELECTRONIC COMPONENTS

Open the catalog to page 1
DF11 - 2

Power entry modules without line filter https://www.schurter.com /PG05 Product standards Product standards that are referenced Design Designed according to Designed according to Designed according to Standard Description IEC 60320-1 Appliance couplers for household and similar general purposes UL 60320-1 Standard for Attachment Plugs and Receptacles CSA C22.2 no. 60320-1 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Application standards Application standards where the product can be used Organization Design Standard Designed for applications...

Open the catalog to page 2
DF11 - 3

Power entry modules without line filter https://www.schurter.com /PG05 Snap-in version * --- Version TA45 with undervoltage release

Open the catalog to page 3
DF11 - 4

Power entry modules without line filter https://www.schurter.com /PG05 Table 1 Selection for type TA45 Order example • Circuit Breaker of Equipment • 2-pole, rocker actuated • Quick connect terminal Other types on request Diagram Thermal overload protection Without illumination With illumination Colours Switch front black black black white black – – – orange transp. Rocker legend Illustration white / weiss printed / bedruckt printed / bedruckt printed / bedruckt embossed / Relief Position of the rocker legend e.g F white / weiss black / schwarz Rated current circuit breaker of equipment In...

Open the catalog to page 4
DF11 - 5

Power entry modules without line filter https://www.schurter.com /PG05 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A Rated current Ambient temp. Rated current Ambient temp. Multiple of rated current Multiple of rated current Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been...

Open the catalog to page 5
DF11 - 6

Power entry modules without line filter https://www.schurter.com /PG05 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete Connector further types to DF11 Mating Outlets/Connectors shuttered Power Cord Overview complete VAC13KS, Overview, diverse Connector IEC C13, cord end: VAC13KS Power Cord further types to DF11 Connectors ELECTRONIC COMPONENTS The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be...

Open the catalog to page 6

All SCHURTER catalogs and technical brochures

  1. FMAD NEO

    6 Pages

  2. THS

    5 Pages

  3. TTS

    4 Pages

  4. Product News

    4 Pages

  5. FMAB NEO

    12 Pages

  6. FPG1

    4 Pages

  7. FMAB HV

    6 Pages

  8. UMT-W

    4 Pages

  9. OGN

    3 Pages

  10. 0712

    3 Pages

  11. CPS

    7 Pages

  12. DG12

    10 Pages

  13. 4751

    4 Pages

  14. FMAD CP

    4 Pages

  15. 4783

    4 Pages

  16. EF11

    8 Pages

  17. PFRY

    4 Pages

  18. PFRA

    6 Pages

  19. PFMF

    4 Pages

  20. PFHT

    3 Pages

  21. PFDF

    3 Pages

  22. 6051.2067

    3 Pages

  23. 6051.2068

    3 Pages

  24. 4797-5

    4 Pages

  25. 6051.2063

    3 Pages

  26. 6051.2061

    3 Pages

  27. 6051.2015

    3 Pages

  28. 3-108-993

    2 Pages

  29. 3-100-361

    3 Pages

  30. GP21

    3 Pages

  31. FMER SOL

    10 Pages

  32. CMF2, CMF5

    3 Pages

  33. CDS1

    5 Pages

  34. DKIH-3

    6 Pages

  35. 4710-5

    5 Pages

  36. Touchkit

    3 Pages

  37. USN 1206

    3 Pages

  38. FPBB RAIL

    7 Pages

  39. DD14

    8 Pages

  40. VAC19KS

    3 Pages

  41. UMK 250

    4 Pages

  42. 4761

    3 Pages

  43. 4732

    4 Pages

  44. FUS

    3 Pages

  45. DKIH

    6 Pages

  46. FSO

    2 Pages

  47. CSO

    3 Pages

  48. CMF1, CMF4

    3 Pages

  49. FMAC NEO

    5 Pages

  50. MSM DP 30

    8 Pages

  51. PSE AE 16

    3 Pages

  52. MSM LA CS 22

    7 Pages

  53. MSM LA CS 19

    6 Pages

  54. PSE AE 30

    5 Pages

  55. PSE EX 16

    5 Pages

  56. PSE EX 19

    5 Pages

  57. PSE NO 19

    6 Pages

  58. PSE NO 16

    6 Pages

  59. PSE EX 22

    5 Pages

  60. PSE NO 27

    6 Pages

  61. PSE NO 24

    6 Pages

  62. PSE NO 22

    8 Pages

  63. PSE IV 16

    6 Pages

  64. PSE HI 22

    6 Pages

  65. PSE NO 30

    7 Pages

  66. PSE M22 IV

    7 Pages

  67. MCS ES 18

    3 Pages

  68. MCS ES 22

    3 Pages

  69. 6051.2094

    3 Pages

  70. 6051.2093

    3 Pages

  71. 6051.2078

    3 Pages

  72. 6051.2077

    3 Pages

  73. 6051.2070

    3 Pages

  74. 6051.2072

    3 Pages

  75. 6051.2071

    3 Pages

  76. 6051.2037

    2 Pages

  77. 6051.2030

    3 Pages

  78. 6051.2032

    3 Pages

  79. 6051.2031

    3 Pages

  80. 6051.2027

    3 Pages

  81. 3-107-570

    2 Pages

  82. 3-107-569

    2 Pages

  83. VAC13KS

    4 Pages

  84. DD21

    5 Pages

  85. DD11

    5 Pages

  86. DG11

    7 Pages

  87. typ_4762

    3 Pages

  88. SWA2

    2 Pages

  89. PB 1021

    2 Pages

  90. TM12-111

    6 Pages

  91. PTS

    4 Pages

  92. PB 1011

    2 Pages

  93. FMAD CEE

    3 Pages

Archived catalogs

  1. Product News

    4 Pages

  2. PFDF

    3 Pages

  3. PFHT

    3 Pages

  4. PFUF

    3 Pages

  5. DKFP

    5 Pages

  6. FMAD RAIL

    3 Pages

  7. FMAC RAIL

    3 Pages

  8. FMBD NEO

    6 Pages

  9. FMAC SINE

    4 Pages

  10. FMAB RAIL

    3 Pages

  11. FMBB NEO

    11 Pages

  12. FMBB RAIL

    3 Pages

  13. 5120

    10 Pages

  14. SMD-FTT

    1 Pages

  15. OMZ 125

    1 Pages

  16. 4840.2200

    2 Pages

  17. 6051.5003

    2 Pages

  18. 6000.0224

    2 Pages

  19. 6051.2030

    2 Pages

  20. 6051.2003

    2 Pages

  21. FLBB

    2 Pages

  22. 4741

    2 Pages

  23. P685

    2 Pages

  24. KE

    4 Pages

  25. GSF2

    4 Pages

  26. GSF1

    5 Pages

  27. Felcom 64

    4 Pages

  28. 6135

    5 Pages

  29. DC21

    3 Pages

  30. 1074

    4 Pages

  31. DC11

    5 Pages

  32. CMF3, CMF6

    2 Pages

  33. PFNF

    3 Pages

  34. ESO 10.3x38

    1 Pages

  35. SHT 6.3x32

    1 Pages

  36. KEB2

    1 Pages

  37. ASO / FSO

    8 Pages

  38. Varistors

    40 Pages

  39. Flyer MGA-S