Catalog excerpts

6135-1

Power entry modules without line filter www.schurter.com/PG05 IEC Appliance Inlet C14 with Circuit Breaker TA35 2-pole - Panel Mount: Snap-in version from front side - 2 Functions: Appliance Inlet, Protection class I, Circuit breaker type TA35, 2-pole - Quick connect terminal 6.3 x 0.8 mm - Unwired - Switch non-illuminated or illuminated Thermal overload protection - Suitable for use in equipment according to IEC/UL 60950 Other versions on request - Pre-wired version - Quick connect terminals 4.8 x 0.8 mm - Protection class II, 70°C Alternative: version for 16 A (20 A) Substitute for type 7764 pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CADDrawings, Accessories, Detailed request for product Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC Ratings UL/CSA Dielectric Strength Allowable Operation Temp. Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 2.5 kVAC between L-N > 3 kVAC between L/N-PE (1 min/50 Hz) -25 °C to 60 °C from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Snap-in1.5/2/2.5 mm Thermoplastic, black, UL 94V-0 Appliance Inlet Circuit Breakers C14 acc. to IEC 60320 UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Conditional short circuit Inc: 2000 A

 Open the catalog to page 1
6135-2

Power entry modules without line filter

 Open the catalog to page 2
6135-3

Power entry modules without line filter ORDER CODE Number of switched poles Number of protected poles Table 1 Selection for type TA35 Order example Switch without Other versions on request Switch front Other colours on request Rocker legend Surface Illustration Colour of print Other legends on request Other rated currents on request ') UL/CSA only

 Open the catalog to page 3
6135-4

Power entry modules without line filter Technical data (continued) Circuit breaker Tripping characteristics Tripping characteristics The above tripping characteristics apply to symmetrical overloads on the two poles. At asymmetric overloads on two pole types the tripping current will be increased by factor 1.05 (TC-2). Effect of ambient temperature The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. " Temperature must be measured at the rear of the breaker next to the...

 Open the catalog to page 4
6135-5

Power entry modules without line filter www.schurter.com/PG05 Packaging unit Accessories Description Assorted Covers Rear Cover Cord retaining kits Cord retaining strain relief Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal Appliance Outlet further types to 6135   Connector Overview complete IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Angled IEC Connector C13, Rewireable,...

 Open the catalog to page 5

All SCHURTER catalogs and technical brochures

  1. FMAD NEO

    6  Pages

  2. THS

    5  Pages

  3. TTS

    4  Pages

  4. FMAB NEO

    12  Pages

  5. UMT-W

    4  Pages

  6. OGN

    3  Pages

  7. 0712

    3  Pages

  8. 4751

    4  Pages

  9. FMAD CP

    4  Pages

  10. 4783

    4  Pages

  11. EF11

    8  Pages

  12. PFMF

    4  Pages

  13. PFDF

    3  Pages

  14. 4797-5

    4  Pages

  15. 6051.2063

    3  Pages

  16. 6051.2061

    3  Pages

  17. 6051.2015

    3  Pages

  18. 3-108-993

    2  Pages

  19. 3-100-361

    3  Pages

  20. GP21

    3  Pages

  21. FMER SOL

    10  Pages

  22. CMF2, CMF5

    3  Pages

  23. CDS1

    5  Pages

  24. DKIH-3

    6  Pages

  25. 4710-5

    5  Pages

  26. Touchkit

    3  Pages

  27. USN 1206

    3  Pages

  28. FPBB RAIL

    7  Pages

  29. DD14

    8  Pages

  30. VAC19KS

    3  Pages

  31. UMK 250

    4  Pages

  32. 4761

    3  Pages

  33. 4732

    4  Pages

  34. FUS

    3  Pages

  35. DKIH

    6  Pages

  36. FSO

    2  Pages

  37. CSO

    3  Pages

  38. CMF1, CMF4

    3  Pages

  39. FMAC NEO

    5  Pages

  40. MSM DP 30

    8  Pages

  41. PSE AE 16

    3  Pages

  42. MSM LA CS 22

    7  Pages

  43. MSM LA CS 19

    6  Pages

  44. PSE AE 30

    5  Pages

  45. PSE EX 16

    5  Pages

  46. PSE EX 19

    5  Pages

  47. PSE NO 19

    6  Pages

  48. PSE NO 16

    6  Pages

  49. PSE EX 22

    5  Pages

  50. PSE NO 27

    6  Pages

  51. PSE NO 24

    6  Pages

  52. PSE NO 22

    8  Pages

  53. PSE IV 16

    6  Pages

  54. PSE HI 22

    6  Pages

  55. PSE NO 30

    7  Pages

  56. PSE M22 IV

    7  Pages

  57. MCS ES 18

    3  Pages

  58. MCS ES 22

    3  Pages

  59. 6051.2094

    3  Pages

  60. 6051.2093

    3  Pages

  61. 6051.2078

    3  Pages

  62. 6051.2077

    3  Pages

  63. 6051.2070

    3  Pages

  64. 6051.2072

    3  Pages

  65. 6051.2071

    3  Pages

  66. 6051.2037

    2  Pages

  67. 6051.2030

    3  Pages

  68. 6051.2032

    3  Pages

  69. 6051.2031

    3  Pages

  70. 6051.2027

    3  Pages

  71. 3-107-570

    2  Pages

  72. 3-107-569

    2  Pages

  73. VAC13KS

    4  Pages

  74. DD21

    5  Pages

  75. DD11

    5  Pages

  76. DF11

    6  Pages

  77. DG11

    7  Pages

  78. typ_6051.2016

    3  Pages

  79. typ_6051.2008

    3  Pages

  80. typ_6051.2009

    3  Pages

  81. typ_6051.2001

    4  Pages

  82. typ_6051.2007

    3  Pages

  83. typ_6051.2003

    3  Pages

  84. typ_6051.2004

    3  Pages

  85. typ_4762

    3  Pages

  86. typ_3-101-514

    3  Pages

  87. typ_3-101-501

    3  Pages

  88. typ_3-100-528

    3  Pages

  89. typ_3-100-734

    3  Pages

  90. typ_3-100-526

    3  Pages

  91. typ_3-100-523

    3  Pages

  92. typ_3-100-524

    3  Pages

  93. typ_3-100-527

    3  Pages

  94. typ_3-100-522

    3  Pages

  95. typ_3-100-356

    3  Pages

  96. typ_3-100-355

    3  Pages

  97. typ_3-100-354

    3  Pages

  98. SWA2

    2  Pages

  99. PB 1021

    2  Pages

  100. TM12-111

    6  Pages

  101. PTS

    4  Pages

  102. Piezo Keypads

    4  Pages

  103. PB 1011

    2  Pages

  104. FMAD CEE

    3  Pages

Archived catalogs

  1. 6051.2068

    3  Pages

  2. Company Profile

    20  Pages

  3. Product News

    4  Pages

  4. PFRY

    4  Pages

  5. 6051.2067

    3  Pages

  6. PFRA

    6  Pages

  7. FMAB HV

    6  Pages

  8. DG12

    10  Pages

  9. FPG1

    4  Pages

  10. CPS

    7  Pages

  11. 2020 PFHT

    3  Pages

  12. PFDF

    3  Pages

  13. ASO / FSO

    8  Pages

  14. PFUF

    3  Pages

  15. 2015 PFHT

    3  Pages

  16. KEB2

    1  Page

  17. SHT 6.3x32

    1  Page

  18. ESO 10.3x38

    1  Page

  19. PFNF

    3  Pages

  20. CMF3, CMF6

    2  Pages

  21. DC11

    5  Pages

  22. 1074

    4  Pages

  23. DC21

    3  Pages

  24. Felcom 64

    4  Pages

  25. GSF1

    5  Pages

  26. GSF2

    4  Pages

  27. KE

    4  Pages

  28. P685

    2  Pages

  29. 4741

    2  Pages

  30. FLBB

    2  Pages

  31. 6051.2003

    2  Pages

  32. 6051.2030

    2  Pages

  33. 6000.0224

    2  Pages

  34. 6051.5003

    2  Pages

  35. 4840.2200

    2  Pages

  36. OMZ 125

    1  Page

  37. SMD-FTT

    1  Page

  38. 5120

    10  Pages

  39. FMBB RAIL

    3  Pages

  40. FMBB NEO

    11  Pages

  41. FMAB RAIL

    3  Pages

  42. FMAC SINE

    4  Pages

  43. FMAC SINE DCL

    4  Pages

  44. FMBD NEO

    6  Pages

  45. FMAC RAIL

    3  Pages

  46. FMAD RAIL

    3  Pages

  47. DKFP

    5  Pages

  48. Varistors

    40  Pages

  49. Flyer MGA-S

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.