Catalog excerpts
echnical Data Sheet SDC Rectifier / Battery Charger >24-220V >25-1200 A H la-s y I i i GUTOR Schneider Electric
Open the catalog to page 1Technical data SDC Voltage 3x380/400/415V Input voltage tolrance: DC in tolrance +/-10 % for function +15 %/-25 % (below -15 % the battery might begin to discharge) Frequency 50 / 60 Hz Frequency tolerance +/- 8 % Power factor: at nominal line power and float voltage ~ 0.83 at -10 % line power and float voltage ~ 0.90 at +10 % line power and float voltage ~ 0.75 Rectifier input Voltage 24/48/110/125/220VDC Setting range: Float voltage at -10 /+10 % line power voltage 100-120 % Float voltage at 0 /+10 % line power voltage 100-130 % Boost voltage at nominal line power voltage 100-130 %...
Open the catalog to page 2Cat Gen GB 2004 table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:12.00pt "Arial", sans-serif; } .font1 { font:13.00pt "Arial", sans-serif; } .font2 { font:32.00pt "Arial", sans-serif; } .font3 { font:4.00pt "Lucida Sans Unicode", sans-serif; } .font4 { font:5.00pt "Lucida Sans Unicode", sans-serif; } .font5 { font:6.00pt "Lucida Sans Unicode", sans-serif; } .font6 { font:8.00pt "Lucida Sans Unicode", sans-serif; } .font7 { font:13.00pt "Lucida Sans Unicode", sans-serif; } Spcification SDC Bottom cable entry Typical single-line drawing Ground terminal rWI...
Open the catalog to page 3Human-machine interface (front panel) The front panel, which is identical for both AC and DC Systems, includes a comprehensive and flexible human-machine i nterface. It is divided into four sections: The system panel shows the system's current state of operation (which part of the system is currently supplying the load and which is in stand-by mode). LEDs also indicate possible faults. Oprations for turning on and off the system and a lamp test button for checking whether all LED indications are functioning properly. To shut down the system, you have to press the ON and OFF buttons at the...
Open the catalog to page 4All Schneider Electric catalogs and technical brochures
-
MGE Galaxy 3500
3 Pages
-
Smart-UPS VT
4 Pages
-
Symmetra MW
4 Pages
-
Symmetra 230 V
4 Pages
-
Smart-UPS On-Line 230 V
12 Pages
-
Smart-UPS 230 V
8 Pages
-
Technical Data Sheet_PXP
4 Pages
-
Technical Data Sheet_WxW
4 Pages
-
Technical Data Sheet_PxW
4 Pages
-
Customer_Service
8 Pages
-
Nuclear_Industry
6 Pages
-
flyer_PXP
4 Pages
-
flyer_PxW
4 Pages
Archived catalogs
-
Power Supply Protection
23 Pages
-
Your Global Partner
5 Pages