4-16 kVA N + 1 Redundant rack/tower convertible 13U-19U, 4-16 kVA N + 1 Redundant extended run tower Highly available, redundant, and scalable double-conversion on-line power protection The first UPS with redundancy and scalability within a single chassis Symmetra™ 230 V uses a modular, redundant architecture that can scale power and runtime as demand increases or when higher levels of availability are required. • Configurable for N+1 internal redundancy • Scalable power capacity • Manageable external batteries • Network manageable • LCD display • Modular design • Automatic internal bypass • Frequency and vol
Open the catalog to page 1Features and benefits Symmetra 230 V Battery systems Power distribution Additional battery modules or external battery frames can be added to achieve desired levels of runtime. Symmetra LX battery modules and frames are hot-swappable so you never have to bring down your mission critical loads to service the unit. Field replaceable receptacle panels allow direct connection enabling fast installation of new IT equipment. SYPD10 230 V backplate kit with (2) IEC320 C19 and (1) IEC 60309 SYBT5 Battery module for APC Symmetra LX SYARMXR3B3I, SYARMXR9B9I, SYAXR9B9I Symmetra LX Extended Run Battery Frames...
Open the catalog to page 2Symmetra 230 V Highly available, redundant, and scalable double-conversion on-line power protection Robust frame - Provides “slots” for modules to connect to communication and DC back planes. No intelligence or active components for highest reliability Power 2 module - Provides flexibility to scale power, adds N+1 capability and is hotswappable for easy, risk-free maintenance Battery module - Scalable for more runtime, hot-swappable for easy, risk-free replacement, N+1 redundant Intelligence modules - Redundant intelligence 4 modules that are hot-swappable for easy riskfree maintenance Single...
Open the catalog to page 38,000 W 9,000 W 10,000 W 11,000 W Full load Half load For more runtime options visit www.apc.com Technical specifications Symmetra 4-16 kVA rack and tower units Output Nominal output voltage Efficiency at full load Output frequency (sync to mains) Waveform type Sine wave Output power capacity Output connections 2,800-11,200 W Tower - (1) Hard-wire 3-wire (H N + G), 16 kVA Rack frame - (1) Hard-wire 3-wire (H N + G), (8) IEC 320 C13 (10) IEC 320 C19, 8 kVA Rack frame - (1) Hard-wire 3-wire (H N + G), (8) IEC 320C13 (6) IEC 320 C19 Input Nominal input voltage Input frequency Input connections Bypass...
Open the catalog to page 43 Pages
4 Pages
4 Pages
12 Pages
8 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
6 Pages
4 Pages
4 Pages
23 Pages
5 Pages